EBK ORGANIC CHEMISTRY-STUD.SOLNS.MAN+SG
EBK ORGANIC CHEMISTRY-STUD.SOLNS.MAN+SG
4th Edition
ISBN: 9781119659525
Author: Klein
Publisher: WILEY CONS
bartleby

Concept explainers

Question
Book Icon
Chapter 13.11, Problem 20CC

(a)

Interpretation Introduction

Interpretation: Starting material and reagent used to prepare the given thiols need to be identified.

  EBK ORGANIC CHEMISTRY-STUD.SOLNS.MAN+SG, Chapter 13.11, Problem 20CC , additional homework tip  1

Concept introduction: preparation of thiol can be done when alkyl halide reacts with sodium hydrosulfide. The reaction follows the SN2 mechanism. Here, the substitution of the SH group takes place, and halide act as leaving group. Since it is an SN2 reaction, thus, inversion of the configuration takes place.

(b)

Interpretation Introduction

Interpretation: Starting material and reagent used to prepare the given thiols need to be identified.

  EBK ORGANIC CHEMISTRY-STUD.SOLNS.MAN+SG, Chapter 13.11, Problem 20CC , additional homework tip  2

Concept introduction: preparation of thiol can be done when alkyl halide reacts with sodium hydrosulfide. The reaction follows the SN2 mechanism. Here, the substitution of the SH group takes place, and halide act as leaving group. Since it is an SN2 reaction, thus, inversion of the configuration takes place.

(c)

Interpretation Introduction

Interpretation: Starting material and reagent used to prepare the given thiols need to be identified.

  EBK ORGANIC CHEMISTRY-STUD.SOLNS.MAN+SG, Chapter 13.11, Problem 20CC , additional homework tip  3

Concept introduction: preparation of thiol can be done when alkyl halide reacts with sodium hydrosulfide. The reaction follows the SN2 mechanism. Here, the substitution of the SH group takes place, and halide act as leaving group. Since it is an SN2 reaction, thus, inversion of the configuration takes place.

Blurred answer
Students have asked these similar questions
Recent advancements in liquid chromatography include the development of ultrahigh pressure liquid chromatography (UHPLC) and an increased use of capillary columns that had previously only been used with gas chromatography. Both of these advances have made the development of portable LC systems possible. For example, Axcend Corp. makes a portable system that uses a capillary column with an internal diameter of 150-μm-that is packed with 1.7-um stationary phase particles. In contrast, a traditional LC column has a 4.6 mm internal diameter and utilizes 5-um stationary phase particles. a) Explain one advantage that is afforded by the use of a capillary column in liquid chromatographic separation. Explain one disadvantage of capillary columns. b) Explain how the use of smaller stationary phase particles can improve the resolution of a separation. Include any relevant equations that support your explanation. c) A scientist at Rowan University is using the Axcend LC to conduct analyses of F…
This paper describes the use of fullerene molecules, also known as buckyballs, as a stationary phase for liquid chromatography. The performance of the fullerene-modified stationary phase (FMS) is compared to that of a more common C18 stationary phase and to two other carbon-based stationary phases, PGC and COZ. A. 10A OM B. - Figure 1. Idealized drawing of the cross-section of a pore inside a silica particle, showing the relative densities of aminopropylsilyl (red/green) and fullerene (blue) groups: (A) full cross- section; (B) detailed view of covalent bonding of fullerene to the silica surface. Surface densities of silyl and fullerene groups were inferred from elemental composition results obtained at each stage of the synthesis (see Table 1). Absorbance (mAU, 220 nm) 700 600 500 400 300 200 100 a. Define selectivity, a, with words and an equation. b. Explain how the choice of stationary phase affects selectivity. c. Calculate the resolution of the nitrobenzene and toluene peaks in…
Normalized Intensity (a. u.) 0.5 1.0 A 3D-printed GC column (shown below) was created for use with "micro" gas chromatography applications. To prove its utility, it was used to separate a mixture of alkanes (C9-C18, C22, C24). For the separation shown below, the column temperature was ramped from 40 °C to 250 °C at a rate of 30 °C per minute. (a) 9 10 = 1 mm 12 13 15 22 0.0 0 100 200 300 400 Time (sec) a) What detector would you use for this analysis? Justify your selection. b) Explain how the chromatogram would change if the separation was run isothermally. c) Explain how the chromatogram would change if the temperature ramp were increased to 50 °C per minute.

Chapter 13 Solutions

EBK ORGANIC CHEMISTRY-STUD.SOLNS.MAN+SG

Knowledge Booster
Background pattern image
Chemistry
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
SEE MORE QUESTIONS
Recommended textbooks for you
Text book image
Chemistry for Today: General, Organic, and Bioche...
Chemistry
ISBN:9781305960060
Author:Spencer L. Seager, Michael R. Slabaugh, Maren S. Hansen
Publisher:Cengage Learning
Text book image
Organic Chemistry: A Guided Inquiry
Chemistry
ISBN:9780618974122
Author:Andrei Straumanis
Publisher:Cengage Learning
Text book image
Organic And Biological Chemistry
Chemistry
ISBN:9781305081079
Author:STOKER, H. Stephen (howard Stephen)
Publisher:Cengage Learning,
Text book image
General, Organic, and Biological Chemistry
Chemistry
ISBN:9781285853918
Author:H. Stephen Stoker
Publisher:Cengage Learning
Text book image
Introduction to General, Organic and Biochemistry
Chemistry
ISBN:9781285869759
Author:Frederick A. Bettelheim, William H. Brown, Mary K. Campbell, Shawn O. Farrell, Omar Torres
Publisher:Cengage Learning
Text book image
Organic Chemistry
Chemistry
ISBN:9781305080485
Author:John E. McMurry
Publisher:Cengage Learning