Fundamentals of Heat and Mass Transfer
7th Edition
ISBN: 9780470501979
Author: Frank P. Incropera, David P. DeWitt, Theodore L. Bergman, Adrienne S. Lavine
Publisher: Wiley, John & Sons, Incorporated
expand_more
expand_more
format_list_bulleted
Question
Chapter 10, Problem 10.56P
To determine
The expression for time
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
All properties should be evaluated at the temperature of the steam.Saturated, pure steam at 65 ºC condenses on the surface of a vertical tube with outersurface diameter 2 cm which is maintained at a uniform temperature of 35 ºC. Determinethe tube length for a condensate flow rate of 5 x 10-3 kg/s.
Explain step-by-step
Water at atmospheric pressure is boiled in a container using a horizontal 8 mm electric wire (ε=0.9) whose temperature is maintained by an electric current at 250oC. Estimate the boiling heat transfer coefficient between the water and the wire surface. Properties of Water, liquid: ρl = 957.9 kg/m3, hfg = 2257 kJ/kg, vapor: ρv = 4.8 kg/m3, Cp,v = 2560 J/kg.K, μv = 14.85*10-6 N.s/m2, kv=0.0331 W/mK.
Select one:
a. 247 W/m2K
b. 440 W/m2K
c. 90.7 W/m2K
d. 710 W/m2K
Chapter 10 Solutions
Fundamentals of Heat and Mass Transfer
Ch. 10 - Show that, for water at 1-atm pressure with...Ch. 10 - The surface of a horizontal. 7-mm-diameter...Ch. 10 - The role of surface tension in bubble formation...Ch. 10 - Estimate the heat transfer coefficient, h,...Ch. 10 - Prob. 10.5PCh. 10 - Prob. 10.6PCh. 10 - Prob. 10.7PCh. 10 - Prob. 10.8PCh. 10 - Calculate the critical heat flux on a large...Ch. 10 - Prob. 10.11P
Ch. 10 - Prob. 10.12PCh. 10 - Prob. 10.13PCh. 10 - Prob. 10.15PCh. 10 - Prob. 10.16PCh. 10 - Consider a gas-fired boiler in which five coiled,...Ch. 10 - Prob. 10.18PCh. 10 - Prob. 10.19PCh. 10 - Prob. 10.20PCh. 10 - Prob. 10.22PCh. 10 - Prob. 10.24PCh. 10 - Prob. 10.25PCh. 10 - A small copper sphere, initially at a uniform,...Ch. 10 - Prob. 10.28PCh. 10 - A disk-shaped turbine rotor is heat-treated by...Ch. 10 - A steel bar, 20 mm in diameter and 200 mm long,...Ch. 10 - Electrical current passes through a horizontal....Ch. 10 - Consider a horizontal. D=1 -mm-diameter platinum...Ch. 10 - Prob. 10.34PCh. 10 - Prob. 10.35PCh. 10 - Prob. 10.36PCh. 10 - Prob. 10.37PCh. 10 - A polished copper sphere of 10-mm diameter,...Ch. 10 - Prob. 10.39PCh. 10 - Prob. 10.40PCh. 10 - Consider refrigerant R-134a flowing in a smooth,...Ch. 10 - Determine the tube diameter associated with p=1...Ch. 10 - Saturated steam at 0.1 bar condenses with a...Ch. 10 - Prob. 10.45PCh. 10 - Prob. 10.46PCh. 10 - Prob. 10.47PCh. 10 - Prob. 10.48PCh. 10 - Prob. 10.50PCh. 10 - Prob. 10.53PCh. 10 - The condenser of a steam power plant consists of...Ch. 10 - Prob. 10.56PCh. 10 - Prob. 10.61PCh. 10 - Prob. 10.62PCh. 10 - A technique for cooling a multichip module...Ch. 10 - Determine the rate of condensation on a 100-mm...Ch. 10 - Prob. 10.66PCh. 10 - Prob. 10.67PCh. 10 - Prob. 10.70PCh. 10 - Prob. 10.71PCh. 10 - Prob. 10.74PCh. 10 - Prob. 10.75PCh. 10 - A thin-walled cylindrical container of diameter D...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Consider a tank with surface area A.(m2) It containsa fluid of M(kg) at an initial temperature of T0. (C) The specific heat of the fluid is Cp. (J/kg) The fluid inside the tank is heated with condensing vapour outside at temperature of Ts. find the equation that gives the change of the temperature of the fluid in the tank with time.T=f(t) neglect donduction heat transfer h=heat transfer film coef. homogenous T through the tankarrow_forwardSaturated steam at 1 atm condenses on a 3 m high and 5 m wide vertical plate that is maintained at o 90 C by circulating cooling water through the other side. Determine: a) The rate of heat transfer by condensation to the plate, and b) The rate at which the condensate drips off the plate at the bottom.arrow_forwardA certain gas was produced as a product of a decomposition reaction in a reactor vessel. The reaction generated a certain amount of force that allowed the gas to move at 35 m/s. The diatomic product gas (gamma = 1.36) will be transported adiabatically in a commercial steel pipe with a diameter of 1 inch. If the exit of the reactor and start of the pipe has a same pressure of 6 atm abs. and temperature of 120 degrees Celsius. The molecular weight of the gas is 70.91 kg/kgmol. 2. What is the Mach No. at the entry of the pipe? 0.36 0.41 0.14 none of the given 0.25 0.52 0.63arrow_forward
- Only answer if you are 100% sure otherwise i will downvote... An ASTM B75 copper tube sheathes a heating element that is used to boil water at 1254 kPa. The copper tube is immersed horizontally in the water, and its surface is polished. The tube diameter and length are 5 mm and 9.5 cm, respectively. The maximum use temperature for ASTM B75 copper tube is 204°C. Determine the highest evaporation rate of water that can be achieved by the heater without heating the tube surface above the maximum use temperature. Use the property tables to calculate the properties of water at saturation temperature. The surface tension 0 at 190°C is 0.03995 N/m. Also, Csf 0.0130 and 10 for the boiling water on a polished copper surface. The highest evaporation rate of water is g/s?arrow_forwardDesign a hydrocooling unit to cool down fruits and vegetables from 30 °C to 5 °C in 20 minutes at a rate of 20,000 kg of fruit or vegetables/h. The design must fulfill the following requirements: The unit will be an immersion flooded system. It must be able to cool down and transport the products in chill water. The tank has the following dimensions approximate. three meters wide and up to 90 cm hight. The water will circulate and be cooled through the evaporation section of a refrigeration system. The refrigerant temperature inside the coils will be -2 °C, and the water temperature must not drop below 1 °C and must not exceed 6 °C. Assuming reasonable values for the average density, specific heat, and porosity of the product (the fraction of the volume of air in a box), recommend reasonable values for: The speed of the water through the canal, the capacity of the cooling system. the compressor power.arrow_forwardWater at 900 C and a rate of 0.5 kg/s is cooled to 45° C in a copper pipe of 2 cm outer diameter and 2 mm thickness by a vapor that is condensing on its outer surface at 30° C: a. Determine the pipe length. b. Determine the pressure drop.arrow_forward
- AH of vaporization of water is 439.2 cal/g at the normal boing point. Since virus can survive at 404.39 K by forming spores. Most virus spores die at 851.9 K. Hence, autoclaves used to sterilize medical and laboratory instruments are pressurized to raise the boiling point of water to 851.9 K. Find out at what InP (torr) does water boil at 851.9 K? O a. 8460.435 O b. 940.048 c. 1880.097 O d. 2.474arrow_forwardWater is to be boiled at atmospheric pressure in a polished copper pan by means of an electric heater. The diameter of the pan is 0.51 m and is kept at 111 deg C. What is the power required to boil the water? Tsat = 100°C; Properties of water at 100°C: Density, ρl= 961 kg/m3; Kinematic viscosity, ν = 0.293x10-6 m2/s; Prandtl Number, Pr = 1.740; Specific heat, Cpl = 4216 J/kg.K; Dynamic viscosity, μ = ρ × ν = 961 × 0.293 × 10-6 = 281.57 x10-6 Ns/m2; hfg = 2256.9 kJ/kg; ρv = 0.597 kg/m3; σ = 0.0588 N/m; Csf=0.013; n=1; Select one: a. 25964.0356 b. 52997.1101 c. 49373.4011 d. 38911.7986arrow_forwardSolve itarrow_forward
- The condensation process of vapors on the outside of horizontal tube banks is described by the equation below, NNU = 0.725 (g p² hfg Do³) μ Δt Ν κ At 45 C R-22 properties are: Density, p Dynamic viscosity, μ Latent heat, hfg Thermal conductivity, k where N tubes/row At = hfg AT = difference between wall surface & R-22 NNu Refrigerant - 22 condenser operating at 45 C cooled with water from cooling tower entering at 30 C and leaves at 36 C. The condenser is shell-tube type with copper tubes of 14 mm ID & 16 mm OD arranged with 3 tubes per row (N). a) Compute the convective heat transfer of R-22 in W/m²K. = 1,109 kg/m³ 0.00018 Pa s 160.9 kJ/kg 0.0779 W/m K (*50-45) = 5 C (*from sample problem #2 pipe wall temperature) diff. of temp between wall & fluid latent heat of condensation generally a function of (NR₂. Npr) D/ karrow_forwardP2arrow_forwardThe condensation process of vapors on the outside of horizontal tube banks is described by the equation below, NNU = 0.725 (gp² hfg Do³) μ Δt Ν k where N tubes/row At = hfg Density, p Dynamic viscosity, μ Latent heat, hfg Thermal conductivity, k AT = difference between wall surface & R-22 NNu 3 1,109 kg/m 0.00018 Pa s = Refrigerant - 22 condenser operating at 45 C cooled with water from cooling tower entering at 30 C and leaves at 36 C. The condenser is shell-tube type with copper tubes of 14 mm ID & 16 mm OD arranged with 3 tubes per row (N). a) Considering the results of sample problem #2 (fw = 6,909.4 W/m²K film coefficient at water side), compute the overall heat transfer coefficient based on outer surface area in W/m² K of a water-cooled shell-tube R-22 condenser. At 45 C R-22 properties are: 160.9 kJ/ kg 0.0779 W/m K (*50-45) = 5 C (*from sample problem #2 pipe wall temperature) diff. of temp between wall & fluid latent heat of condensation generally a function of (NR₂. Nor) D/ karrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Heat Transfer (Activate Learning wi...Mechanical EngineeringISBN:9781305387102Author:Kreith, Frank; Manglik, Raj M.Publisher:Cengage LearningRefrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Principles of Heat Transfer (Activate Learning wi...
Mechanical Engineering
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Heat Transfer – Conduction, Convection and Radiation; Author: NG Science;https://www.youtube.com/watch?v=Me60Ti0E_rY;License: Standard youtube license