Introduction To Health Physics
5th Edition
ISBN: 9780071835275
Author: Johnson, Thomas E. (thomas Edward), Cember, Herman.
Publisher: Mcgraw-hill Education,
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 10, Problem 10.23P
(a)
To determine
TVL value of lead.
(b)
To determine
The HVL value of lead.
(c)
To determine
The relationship between TVL and HVL.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
A radioactive source is producing 1.50 MeV gamma rays. If two detectors are placed 4.00 m and 7.00 m away respectively, what is the ratio of the measured intensities of the near detector over the far detector (I2/I1)? Do NOT include units in your answer answer to 2 decimal places.
7
A 228Th source is labeled 1.50 mCi, but its present activity is found to be 3.47 ✕ 106 Bq.
(a)What is the present activity in mCi? mCi
(b)How long ago (in y) did it actually have a 1.50 mCi activity?
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, physics and related others by exploring similar questions and additional content below.Similar questions
- Calculate the dose in Sv to the chest at a patient given an xray under the following conditions. The xray beam intensity is 1.50 W/m2, the area of the chest exposed is 0.0750 m2 35.0% of the xrays are absorbed in 20.0 kg of tissue, and the exposure time is 0.250 s.arrow_forwardData from the appendices and the periodic table may be needed for these problems. A 60Co source is labeled 4.00 mCi, but its present activity is found to be 1.85107Bq. (a) What is the present activity in mCi? (b) How long ago did it actually have a 4.00—mCi activity?arrow_forwardA small 10-gram source of cobalt-60 is in a vacuum. (a) What is the activity of the cobalt-60source in Bq? (b) What is the actual gamma-ray flux in cm2-s-1 at a point of measurement500 cm from the source due to the cobalt-60 emitted gamma-rays? (c) If the backgroundgamma-ray flux in the vicinity of the 10-g source is 7.8×107cm-2-s-1, what is the totalgamma-ray flux at the point of measurement, including the background? (d) What thicknessof a lead shield in cm would have to be placed between the source and the point ofmeasurement to reduce the total of the background plus the uncollided gamma-ray flux fromthe cobalt-60 source to 1.00×108cm-2-s-1 at that point? (I've attempted part a of the problem and don't know how to continue)arrow_forward
- A radiopharmaceutical is labeled with an activity of 480 mCi on April 1 at 6:00am. What is the activity of the formulation in mCi at 6:00am on April 10? The half life of the radioisotope is 8.10 days. Report to the nearest tenth, number only. λ=2.303/t (logN0/N)arrow_forwardPlease solve in 30 minutearrow_forwardA 228Th source is labeled 1.50 mCi, but its present activity is found to be 6.94 x 106 Bq. (a) What is the present activity in mCi? mCi (b) How long ago (in y) did it actually have a 1.50 mCi activity?arrow_forward
- A beam of 5.0 MeV alpha particles (q-2e) has a cross-sectional area of 1.50 cm2. It is incident on flesh (p-950 kg/m³) and penetrates to a depth of 0.70 mm. a) What dose in Gy does the beam provide to the flesh in a time of 3.0 s? b) What effective dose does it provide? Assume the beam to carry a current of 2.50 x 109 A and to have QF - 14.arrow_forwardA 228Th source is labeled 1.50 mCi, but its present activity is found to be 1.73 ✕ 106 Bq. A.) What is the present activity in mCi? =______mCi B.) How long ago did it actually have a 1.50-mCi activity? =_____yarrow_forwardA radiation worker stands 35 cm away from a radioactive source of 30 mCi (11.1 GBq) 99mTc(?? for 99mTc is 0.80 R·cm2/mCi·hr at 1 cm or 18.0 μGy·m2/ GBq·hr at 1 m). Calculate the exposurevalue received by the worker while standing for 1 hr near the source. The isotop half-life is 6 hours.arrow_forward
- b). Compute the thickness of aluminum and lead to transmit 10% of a narrow beam of 0.1Mev gamma radiations. The numerical value of attenuation coefficient for Al and Pb are 0.435cm-1 and 59.7cm-1 respectivelyarrow_forwardThe exposure rate at 1 meter from a point source of 10 mCi of 137CS is(r for 137CS is 3.3 R.cm2/mCi.hr)arrow_forwardA scientist is studying a 2.234 g sample of thorium-229 (t1/2 = 7340 yrs) in a laboratory. (a) What is its activity in Bq? Answer: x 10^ Bq (b) What is its activity in Ci? Answer: x 10^ Ciarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- College PhysicsPhysicsISBN:9781938168000Author:Paul Peter Urone, Roger HinrichsPublisher:OpenStax CollegeModern PhysicsPhysicsISBN:9781111794378Author:Raymond A. Serway, Clement J. Moses, Curt A. MoyerPublisher:Cengage LearningPrinciples of Physics: A Calculus-Based TextPhysicsISBN:9781133104261Author:Raymond A. Serway, John W. JewettPublisher:Cengage Learning
College Physics
Physics
ISBN:9781938168000
Author:Paul Peter Urone, Roger Hinrichs
Publisher:OpenStax College
Modern Physics
Physics
ISBN:9781111794378
Author:Raymond A. Serway, Clement J. Moses, Curt A. Moyer
Publisher:Cengage Learning
Principles of Physics: A Calculus-Based Text
Physics
ISBN:9781133104261
Author:Raymond A. Serway, John W. Jewett
Publisher:Cengage Learning