You and your lab partner are asked to determine the density of an aluminum bar. The mass is known accurately (to four significant figures). You use a simple metric ruler to measure its dimensions and obtain the results for Method A. Your partner uses a precision micrometer and obtains the results for Method B The accepted density of aluminum is 2.702 g/cm 3 . (a) Calculate the average density for each method. Should all the experimental results be included in your calculations? If not, justify any omissions. (b) Calculate the percent error for each method's average value. (c) Calculate the standard deviation for each set of data. (d) Which method's average value is more precise? Which method is more accurate?
You and your lab partner are asked to determine the density of an aluminum bar. The mass is known accurately (to four significant figures). You use a simple metric ruler to measure its dimensions and obtain the results for Method A. Your partner uses a precision micrometer and obtains the results for Method B The accepted density of aluminum is 2.702 g/cm 3 . (a) Calculate the average density for each method. Should all the experimental results be included in your calculations? If not, justify any omissions. (b) Calculate the percent error for each method's average value. (c) Calculate the standard deviation for each set of data. (d) Which method's average value is more precise? Which method is more accurate?
You and your lab partner are asked to determine the density of an aluminum bar. The mass is known accurately (to four significant figures). You use a simple metric ruler to measure its dimensions and obtain the results for Method A. Your partner uses a precision micrometer and obtains the results for Method B
The accepted density of aluminum is 2.702 g/cm3.
(a) Calculate the average density for each method. Should all the experimental results be included in your calculations? If not, justify any omissions.
(b) Calculate the percent error for each method's average value.
(c) Calculate the standard deviation for each set of data.
(d) Which method's average value is more precise? Which method is more accurate?
(a)
Expert Solution
Interpretation Introduction
Interpretation: The average density for each method and the justifications for omissions has to be given.
Concept introduction:
Precision: Is a measurement indicates how well several determination of the same quantity agree.
Accuracy: Is the agreement of a measurement with the accepted value of the quantity.
Percent error: The difference between measured result and the accepted value.
Percenterror=ErrorinmeasurementAcceptedvalue×100%
Error in measurement = Experimentally determined value - Accepted value.
Answer to Problem 21RPS
Average value for Method A is 2.4 g/cm3
Average value for Method B is 3.480 g/cm3
For B, the 5.811 g/cm3 data point can be excluded because it is more than twice as large as all other points for method B. using only the first three points, average = 2.703 g/cm3
Explanation of Solution
Average density Value for Method A and B:
Average density for Method A: 2.2+ 2.3+ 2.7 + 2.44 = 2.4 g/cm3.Average density for Method B: 2.703+ 2.701 + 2.705 + 5.8114 = 3.48 g/cm3
Hence, the average for method A and B are obtained as shown above. B, the 5.811 g/cm3 data point can be excluded because it is more than twice as large as all other points for method B. using only the first three points, average = 2.703 g/cm3
(b)
Expert Solution
Interpretation Introduction
Interpretation: The percent error for each method’s average value has to be calculated.
Concept introduction:
Precision: Is a measurement indicates how well several determination of the same quantity agree.
Accuracy: Is the agreement of a measurement with the accepted value of the quantity.
Percent error: The difference between measured result and the accepted value.
Percenterror=ErrorinmeasurementAcceptedvalue×100%
Error in measurement = Experimentally determined value - Accepted value.
From the above calculation, the percent errors are obtained as shown above.
(c)
Expert Solution
Interpretation Introduction
Interpretation: The standard deviation for each set of data.
Concept introduction:
Precision: Is a measurement indicates how well several determination of the same quantity agree.
Accuracy: Is the agreement of a measurement with the accepted value of the quantity.
Percent error: The difference between measured result and the accepted value.
Percenterror=ErrorinmeasurementAcceptedvalue×100%
Error in measurement = Experimentally determined value - Accepted value.
Answer to Problem 21RPS
Method A: standard deviation = 0.2 g/cm3
Method B: (including all data points) standard deviation = 1.345 g/cm3
Method B: (excluding the 5.811 g/cm3 data point) standard deviation = 0.002 g/cm3
Explanation of Solution
Standard deviation for method A:
SD=∑|x−μ|2Nwhere,xis values in the data set,μisaverage of the data set (mean value), N is no.of data points.Given : Method A = 2.2, 2.3, 2.7, 2.4Find mean value (μ):μ=2.2+2.3+ 2.7+ 2.44 = 2.4DeterminationMeasured valuesDifferencebetweenMeasurementandAverage(x−μ)Square of Difference|x−μ|212.2−0.20.0422.3−0.10.0132.70.30.0942.40.00.0∑|x−μ|2=0.04+0.01+0.09+0.0 = 0.14SD=0.144=0.2g/cm3
Standard deviation for method B:
SD=∑|x−μ|2Nwhere,xis values in the data set,μisaverage of the data set (mean value), N is no.of data points.Given : Method B = 2.703, 2.701, 2.705, 5.811.Find mean value (μ):μ=2.703+ 2.701+ 2.705+ 5.8114 = 3.48DeterminationMeasured valuesDifferencebetweenMeasurementandAverage(x−μ)Square of Difference|x−μ|212.703−0.7770.603722.701−0.7790.606832.705−0.7750.600645.8112.3315.4335∑|x−μ|2=0.6037+0.6068+0.6006+5.4335 = 7.2446SD=7.254=1.345g/cm3
Standard deviation excluding the 5.811 g/cm3 data point is 0.002 g/cm3.
(d)
Expert Solution
Interpretation Introduction
Interpretation:
The method that has the more precise value and accurate has to be given.
Concept introduction:
Precision: Is a measurement indicates how well several determination of the same quantity agree.
Accuracy: Is the agreement of a measurement with the accepted value of the quantity.
Percent error: The difference between measured result and the accepted value.
Percenterror=ErrorinmeasurementAcceptedvalue×100%
Error in measurement = Experimentally determined value - Accepted value.
Explanation of Solution
Method B average is both more precise and more accurate so long as the 5.811 g/cm3 data point is excluded.
Want to see more full solutions like this?
Subscribe now to access step-by-step solutions to millions of textbook problems written by subject matter experts!
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.