
PHYSICAL CHEMISTRY-STUDENT SOLN.MAN.
2nd Edition
ISBN: 9781285074788
Author: Ball
Publisher: CENGAGE L
expand_more
expand_more
format_list_bulleted
Question
Chapter 1, Problem 1.71E
Interpretation Introduction
Interpretation:
The average grade using equation 1.32 if the scores on a 10-point quiz are 3, 5, 7, 3, 4, 9, 7, and 10 is to be calculated.
Concept introduction:
Grade average is a measure of a student's achievement in academics at a college or university level and it is calculated by dividing the total number of points of grade obtained by the total number attempts made by a student. A student’s grade point average results in a mathematical mean or average of all final grades.
Expert Solution & Answer

Want to see the full answer?
Check out a sample textbook solution
Students have asked these similar questions
Reaction Fill-ins Part 2! Predict the
product(s) OR starting material of the
following reactions. Remember,
Hydride shifts are possible if/when a
more stable carbocation can exist
(depending on reaction mechanism)!
Put your answers in the indicated
boxes d.
d.
ง
HCI
A cylinder contains 12 L of water vapour at 150˚C and 5 atm. The temperature of the water vapour is raised to 175˚C, and the volume of the cylinder is reduced to 8.5 L. What is the final pressure of the gas in atmospheres?
assume that the gas is ideal
On the next page is an LC separation of the parabens found in baby wash. Parabens are
suspected in a link to breast cancer therefore an accurate way to quantitate them is desired.
a. In the chromatogram, estimate k' for ethyl paraben. Clearly indicate what values you used for
all the terms in your calculation.
b. Is this a "good" value for a capacity factor? Explain.
c. What is the resolution between n-Propyl paraben and n-Butyl paraben? Again, indicate clearly
what values you used in your calculation.
MAU
| Methyl paraben
40
20
0
-2
Ethyl paraben n-Propyl paraben
n-Butyl paraben
App ID 22925
6
8
min
Chapter 1 Solutions
PHYSICAL CHEMISTRY-STUDENT SOLN.MAN.
Ch. 1 - A bomb calorimeter is a study metal vessel in...Ch. 1 - Difference between the system and the...Ch. 1 - Prob. 1.3ECh. 1 - Prob. 1.4ECh. 1 - Prob. 1.5ECh. 1 - Prob. 1.6ECh. 1 - Prob. 1.7ECh. 1 - A pot of cold water is heated on a stove, and when...Ch. 1 - hat difference is necessary for heat to flow...Ch. 1 - What is the value of FT for a sample of gas whose...
Ch. 1 - What is the value of FP for a sample of gas whose...Ch. 1 - Prob. 1.12ECh. 1 - Hydrogen gas is used in weather balloon because it...Ch. 1 - Prob. 1.14ECh. 1 - A 2.0 L soda bottle is pressurized with 4.5 atm of...Ch. 1 - The Mount Pinatubo volcano eruption in 1991...Ch. 1 - Prob. 1.17ECh. 1 - Scottish physicist W. J. M. Rankine proposed an...Ch. 1 - Use the two appropriate values of R to determine a...Ch. 1 - Prob. 1.20ECh. 1 - Pressures of gases in mixtures are referred to as...Ch. 1 - Earths atmosphere is approximately 80 N2 and 20...Ch. 1 - The atmospheric surface pressure on Venus is 90...Ch. 1 - Prob. 1.24ECh. 1 - Prob. 1.25ECh. 1 - In the anaerobic oxidation of glucose by yeast,...Ch. 1 - What are the slopes of the following lines at the...Ch. 1 - For the following function, evaluate the...Ch. 1 - Determine the expressions for the following,...Ch. 1 - Determine the expressions for the following,...Ch. 1 - Prob. 1.31ECh. 1 - Prob. 1.32ECh. 1 - Prob. 1.33ECh. 1 - Prob. 1.34ECh. 1 - What properties of a nonideal gas do the Vander...Ch. 1 - Prob. 1.36ECh. 1 - Prob. 1.37ECh. 1 - Calculate the Boyle temperatures for carbon...Ch. 1 - Prob. 1.39ECh. 1 - Prob. 1.40ECh. 1 - Table 1.4 show that the second virial coefficient...Ch. 1 - Prob. 1.42ECh. 1 - What is the van der Waals constant a for Ne in...Ch. 1 - Prob. 1.44ECh. 1 - Under what conditions would the van der Waals...Ch. 1 - By definition, the compressibility of an ideal gas...Ch. 1 - The second virial coefficient B and the third...Ch. 1 - Use the approximation 1 x-1 1 x x2 to...Ch. 1 - Why is nitrogen a good choice for the study of...Ch. 1 - Evaluate for a gas following the Redlich-Kwong...Ch. 1 - Numerically evaluate for one mole of methane...Ch. 1 - Under what conditions of volume does a van der...Ch. 1 - At high temperatures, one of the van der Waals...Ch. 1 - Under what conditions of temperature does a...Ch. 1 - The Berthelot equation of state for one mole of...Ch. 1 - Prob. 1.56ECh. 1 - Referring to exercises 1.6 and 1.7, does it matter...Ch. 1 - Prob. 1.58ECh. 1 - Use Figure 1.11 to construct the cyclic rule...Ch. 1 - Prob. 1.60ECh. 1 - Prob. 1.61ECh. 1 - Calculate for one mole of an ideal gas at STP and...Ch. 1 - Prob. 1.63ECh. 1 - Show that = T/p for an ideal gas.Ch. 1 - Determine an expression for V/T p, n in terms of ...Ch. 1 - Prob. 1.66ECh. 1 - Prob. 1.67ECh. 1 - Perform a units analysis on the exponent of the...Ch. 1 - Using the barometric formula, calculate the...Ch. 1 - The barometric formula can also be used for...Ch. 1 - Prob. 1.71ECh. 1 - Prob. 1.72ECh. 1 - Prob. 1.73ECh. 1 - Prob. 1.74ECh. 1 - Prob. 1.75ECh. 1 - Prob. 1.76ECh. 1 - Prob. 1.77ECh. 1 - Prob. 1.78ECh. 1 - Prob. 1.79ECh. 1 - Use the ideal gas law to symbolically prove the...Ch. 1 - Prob. 1.81E
Knowledge Booster
Similar questions
- d. In Figure 4, each stationary phase shows some negative correlation between plate count and retention factor. In other words, as k' increases, N decreases. Explain this relationship between k' and N. Plate Count (N) 4000 3500 2500 2000 1500 1000 Figure 4. Column efficiency (N) vs retention factor (k') for 22 nonionizable solutes on FMS (red), PGC (black), and COZ (green). 3000 Eluent compositions (acetonitrile/water, A/W) were adjusted to obtain k' less than 15, which was achieved for most solutes as follows: FMS (30/70 A/W), PGC (60/40), COZ (80/20). Slightly different compositions were used for the most highly retained solutes. All columns were 50 mm × 4.6 mm id and packed with 5 um particles, except for COZ, which was packed with 3 um particles. All other chromatographic conditions were constant: column length 5 cm, column j.§. 4.6 mm, flow rate 2 mL/min, column temperature 40 °C, and injection volume 0.5 μL Log(k'x/K'ethylbenzene) FMS 1.5 1.0 0.5 0.0 ཐྭ ཋ ཤྩ བྷྲ ; 500 0 5 10…arrow_forwardf. Predict how the van Deemter curve in Figure 7 would change if the temperature were raised from 40 °C to 55 °C. Figure 7. van Desmter curves in reduced coordinates for four nitroalkane homologues (nitropropane, black; nitrobutane, red; nitropentane, blue; and nitrohexane, green) separated on the FMS phase. Chromatographic conditions: column dimensions 50 mm × 4.6 mm id, eluent 30/70 ACN/water, flow rates 0.2-5.0 mL/min, injection volume 0.5 and column temperature 40 °C. No corrections to the plate heights have been made to account for extracolumn dispersion. Reduced Plate Height (h) ° 20 40 60 Reduced Velocity (v) 8. (2) A water sample is analyzed for traces of benzene using headspace analysis. The sample and standard are spiked with a fixed amount of toluene as an internal standard. The following data are obtained: Ppb benzene Peak area benzene Peak area toluene 10.0 252 376 Sample 533 368 What is the concentration of benzene in the sample?arrow_forwardLiquid chromatography has been used to track the concentration of remdesivir (a broad-spectrum antiviral drug, structure shown at right) in COVID patients undergoing experimental treatments. Intensity The authors provide the following details regarding standard solutions preparation: HN CN HO OH NH2 Remdesivir (RDV) stock solution (5000 µg/mL) was prepared by dissolving RDV drug powder using the mixture of DMSO: MeOH (30:70 v/v). The RDV working standard solutions for calibration and quality controls were prepared using methanol in concentrations of 100, 10, 1, 0.1, 0.01 µg/mL. 1, 2.5, 5, 7.5, 10, 25, 50, 75, 100, 250, 500, 1000, and 5000 ng/mL sample solutions were prepared freshly by spiking calibration standard solutions into the blank human plasma samples for method calibration. a) What type of calibration method is being described? Why do you think the authors chose this method as opposed to another? b) Based on the details provided in part a, describe an appropriate method blank…arrow_forward
- Recent advancements in liquid chromatography include the development of ultrahigh pressure liquid chromatography (UHPLC) and an increased use of capillary columns that had previously only been used with gas chromatography. Both of these advances have made the development of portable LC systems possible. For example, Axcend Corp. makes a portable system that uses a capillary column with an internal diameter of 150-μm-that is packed with 1.7-um stationary phase particles. In contrast, a traditional LC column has a 4.6 mm internal diameter and utilizes 5-um stationary phase particles. a) Explain one advantage that is afforded by the use of a capillary column in liquid chromatographic separation. Explain one disadvantage of capillary columns. b) Explain how the use of smaller stationary phase particles can improve the resolution of a separation. Include any relevant equations that support your explanation. c) A scientist at Rowan University is using the Axcend LC to conduct analyses of F…arrow_forwardThis paper describes the use of fullerene molecules, also known as buckyballs, as a stationary phase for liquid chromatography. The performance of the fullerene-modified stationary phase (FMS) is compared to that of a more common C18 stationary phase and to two other carbon-based stationary phases, PGC and COZ. A. 10A OM B. - Figure 1. Idealized drawing of the cross-section of a pore inside a silica particle, showing the relative densities of aminopropylsilyl (red/green) and fullerene (blue) groups: (A) full cross- section; (B) detailed view of covalent bonding of fullerene to the silica surface. Surface densities of silyl and fullerene groups were inferred from elemental composition results obtained at each stage of the synthesis (see Table 1). Absorbance (mAU, 220 nm) 700 600 500 400 300 200 100 a. Define selectivity, a, with words and an equation. b. Explain how the choice of stationary phase affects selectivity. c. Calculate the resolution of the nitrobenzene and toluene peaks in…arrow_forwardNormalized Intensity (a. u.) 0.5 1.0 A 3D-printed GC column (shown below) was created for use with "micro" gas chromatography applications. To prove its utility, it was used to separate a mixture of alkanes (C9-C18, C22, C24). For the separation shown below, the column temperature was ramped from 40 °C to 250 °C at a rate of 30 °C per minute. (a) 9 10 = 1 mm 12 13 15 22 0.0 0 100 200 300 400 Time (sec) a) What detector would you use for this analysis? Justify your selection. b) Explain how the chromatogram would change if the separation was run isothermally. c) Explain how the chromatogram would change if the temperature ramp were increased to 50 °C per minute.arrow_forward
- Devise a synthesis of each compound from the indicated starting material. You may also use any organic compounds with one or two carbons and any needed inorganic reagents. a. Brarrow_forwardPlease help me with #2b & #3 using the data.arrow_forwardHeparin is used as an anti-coagulant. A risk of heparin use is thrombocytopenia, or low platelet count. This risk is minimized with the use of low molecular weight heparins (LMWH), therefore it is desirable to separate LMWH from higher molecular weight heparins. The method of choice to do this is molecular exclusion chromatography. Below is a chromatogram from a molecular exclusion chromatographic run. Peaks ranging from A to J are clearly distinguishable. The heparin mixture that was analyzed had anywhere from 6 to 30 repeat units of monomer (where the heparin with 30 repeat units would be roughly five times the size of the heparin with six repeat units). a. Which letter most likely represents the peak with 6 repeat units given these heparin polymers were separated with molecular exclusion chromatography? b. Explain your reasoning describing the mechanism of retention in molecular exclusion chromatography. 100 80 60 60 Relative Abundance 40 40 E GH 20 20 B A 36 38 40 42 44 46 48 50 50…arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Physical ChemistryChemistryISBN:9781133958437Author:Ball, David W. (david Warren), BAER, TomasPublisher:Wadsworth Cengage Learning,World of Chemistry, 3rd editionChemistryISBN:9781133109655Author:Steven S. Zumdahl, Susan L. Zumdahl, Donald J. DeCostePublisher:Brooks / Cole / Cengage LearningIntroductory Chemistry: An Active Learning Approa...ChemistryISBN:9781305079250Author:Mark S. Cracolice, Ed PetersPublisher:Cengage Learning
- Introductory Chemistry: A FoundationChemistryISBN:9781285199030Author:Steven S. Zumdahl, Donald J. DeCostePublisher:Cengage LearningChemistry for Engineering StudentsChemistryISBN:9781285199023Author:Lawrence S. Brown, Tom HolmePublisher:Cengage Learning

Physical Chemistry
Chemistry
ISBN:9781133958437
Author:Ball, David W. (david Warren), BAER, Tomas
Publisher:Wadsworth Cengage Learning,

World of Chemistry, 3rd edition
Chemistry
ISBN:9781133109655
Author:Steven S. Zumdahl, Susan L. Zumdahl, Donald J. DeCoste
Publisher:Brooks / Cole / Cengage Learning

Introductory Chemistry: An Active Learning Approa...
Chemistry
ISBN:9781305079250
Author:Mark S. Cracolice, Ed Peters
Publisher:Cengage Learning

Introductory Chemistry: A Foundation
Chemistry
ISBN:9781285199030
Author:Steven S. Zumdahl, Donald J. DeCoste
Publisher:Cengage Learning

Chemistry for Engineering Students
Chemistry
ISBN:9781285199023
Author:Lawrence S. Brown, Tom Holme
Publisher:Cengage Learning
