You wish to measure the iron content of the well water on the new property you are about to buy. You prepare a reference standard Fe+ solution with a concentration of 6.99 × 10-4 M. You treat 11.0 mL of this reference with HNO, and excess KSCN to form a red complex and dilute the reference to 50.0 mL. The diluted reference is placed in a cell with a 1.00-cm light path. You then take 35.0 mL of the well water, treat with HN0, and excess KSCN, and dilute to 100.0 mL. This diluted sample is placed in a variable pathlength cell. The absorbance of the reference and the sample solutions match when the pathlength is 2.85 cm. What is the concentration of iron in the well water? For each solution, the zero is set with a blank. [Fe³+ ]well M water

Chemistry
10th Edition
ISBN:9781305957404
Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Chapter1: Chemical Foundations
Section: Chapter Questions
Problem 1RQ: Define and explain the differences between the following terms. a. law and theory b. theory and...
icon
Related questions
Question
You wish to measure the iron content of the well water on the new property you are about to buy. You prepare a reference
standard Fe+ solution with a concentration of 6.99 × 10-4 M. You treat 11.0 mL of this reference with HNO, and excess
KSCN to form a red complex and dilute the reference to 50.0 mL. The diluted reference is placed in a cell with a 1.00-cm
light path. You then take 35.0 mL of the well water, treat with HNO, and excess KSCN, and dilute to 100.0 mL. This
diluted sample is placed in a variable pathlength cell. The absorbance of the reference and the sample solutions match when
the pathlength is 2.85 cm. What is the concentration of iron in the well water? For each solution, the zero is set with
a blank.
[Fe* Iwell water
М
Transcribed Image Text:You wish to measure the iron content of the well water on the new property you are about to buy. You prepare a reference standard Fe+ solution with a concentration of 6.99 × 10-4 M. You treat 11.0 mL of this reference with HNO, and excess KSCN to form a red complex and dilute the reference to 50.0 mL. The diluted reference is placed in a cell with a 1.00-cm light path. You then take 35.0 mL of the well water, treat with HNO, and excess KSCN, and dilute to 100.0 mL. This diluted sample is placed in a variable pathlength cell. The absorbance of the reference and the sample solutions match when the pathlength is 2.85 cm. What is the concentration of iron in the well water? For each solution, the zero is set with a blank. [Fe* Iwell water М
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Complexometric Titrations
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Chemistry
Chemistry
Chemistry
ISBN:
9781305957404
Author:
Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:
Cengage Learning
Chemistry
Chemistry
Chemistry
ISBN:
9781259911156
Author:
Raymond Chang Dr., Jason Overby Professor
Publisher:
McGraw-Hill Education
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Organic Chemistry
Organic Chemistry
Chemistry
ISBN:
9780078021558
Author:
Janice Gorzynski Smith Dr.
Publisher:
McGraw-Hill Education
Chemistry: Principles and Reactions
Chemistry: Principles and Reactions
Chemistry
ISBN:
9781305079373
Author:
William L. Masterton, Cecile N. Hurley
Publisher:
Cengage Learning
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemistry
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY