You are centrifuging a test tube of spherical cells in a buffer solution. The buffer viscosity and density are 0.02 Pa-s and 1.0 g/cm³; the cells have a diameter 4.5 µm and density is 1.2 g/cm3. The centrifuge rotates at 4000 rpm, with sample holders placed 10 cm from the rotation axis. Which of the following changes will result in having your samples sediment in the least amount of time? O Increasing the viscosity of the buffer to 0.04 Pa s. Doubling the length of the test tube. O Reducing the buffer density to 0.8 g/cm³. Increasing the rotation rate to 8000 rpm. Increasing the distance of the sample holder to 20 cm.

Chemistry
10th Edition
ISBN:9781305957404
Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Chapter1: Chemical Foundations
Section: Chapter Questions
Problem 1RQ: Define and explain the differences between the following terms. a. law and theory b. theory and...
icon
Related questions
Question
100%
Question 2
You are centrifuging a test tube of spherical cells in a buffer solution. The buffer
viscosity and density are 0.02 Pa-s and 1.0 g/cm3; the cells have a diameter 4.5 µm
and density is 1.2 g/cm3. The centrifuge rotates at 4000 rpm, with sample holders
placed 10 cm from the rotation axis. Which of the following changes will result in
having your samples sediment in the least amount of time?
Increasing the viscosity of the buffer to 0.04 Pa s.
Doubling the length of the test tube.
Reducing the buffer density to 0.8 g/cm3.
Increasing the rotation rate to 8000 rpm.
O Increasing the distance of the sample holder to 20 cm.
Transcribed Image Text:Question 2 You are centrifuging a test tube of spherical cells in a buffer solution. The buffer viscosity and density are 0.02 Pa-s and 1.0 g/cm3; the cells have a diameter 4.5 µm and density is 1.2 g/cm3. The centrifuge rotates at 4000 rpm, with sample holders placed 10 cm from the rotation axis. Which of the following changes will result in having your samples sediment in the least amount of time? Increasing the viscosity of the buffer to 0.04 Pa s. Doubling the length of the test tube. Reducing the buffer density to 0.8 g/cm3. Increasing the rotation rate to 8000 rpm. O Increasing the distance of the sample holder to 20 cm.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Quality Assurance and Calibration Methods
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Chemistry
Chemistry
Chemistry
ISBN:
9781305957404
Author:
Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:
Cengage Learning
Chemistry
Chemistry
Chemistry
ISBN:
9781259911156
Author:
Raymond Chang Dr., Jason Overby Professor
Publisher:
McGraw-Hill Education
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Organic Chemistry
Organic Chemistry
Chemistry
ISBN:
9780078021558
Author:
Janice Gorzynski Smith Dr.
Publisher:
McGraw-Hill Education
Chemistry: Principles and Reactions
Chemistry: Principles and Reactions
Chemistry
ISBN:
9781305079373
Author:
William L. Masterton, Cecile N. Hurley
Publisher:
Cengage Learning
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemistry
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY