Row 2: Calculated load in amperes divided by voltage factor. Row 3: Row 4: Row 5: Load type: C = continuous; N = noncontinuous; M = motor; R = receptacle. Load modifier, 1.25 for C and M load types, 1.0 for R and N load types. Calculated load amperes (Row 2) multiplied by load modifier (Row 4). 67115 ch04_pip01_085-00998 Row 6: OCPD rating is equal to or next higher standard ampere rating than OCPD selection amperes (Row 5). Row 7: Ampacity of conductor equal to or greater than the calculated load amperes (Row 2). Row 8: Conductor size with ampacity equal to or greater than calculated load amperes (Row 2). Select from Table 310.16 using the appropriate 60°C for circuits rated 100 amperes or less, and the 75°C column for loads over 100 amperes. Row 9: From problem statements. Row 10: From NEC Table 310.15(B)(1)(1). Row 11: From load calculation. Row 12: From problem statements. Row 13: From NEC Table 310.15(C)(1). Row 14: From NEC 310.16 for conductor type specified in the problem statement: (THHN/THWN). Row 15: Value from Row 13 multiplied by correction and/or adjustment factors. This value must be equal to or greater than the minimum conductor ampacity value in Row 7. 230303 4:07 PM Complete the following table using the following circuits: 1. Eleven 120-volt duplex receptacles for general use. Receptacle loads are considered to be noncontinuous and are not subject to the 80% load limitation as applied for contin- uous loads. 2. Ten 120-volt fluorescent luminaires, rated at 150 volt-amperes each. 3. Eight 120-volt incandescent luminaires, rated at 200 watts or VA each. 4. One 240-volt exhaust fan, rated at 5000 watts or VA. 5. One 120/240-volt single-phase, 3-wire feeder, 40-kVA continuous load, originating in a room with an ambient temperature of 100°F (38°C). ROW CIRCUIT NUMBER 1 Calculated Load in Volt-Amperes Calculated Load in Amperes 2 3 Load Type 4 Load Modifier 5 OCPD Selection Amperes 6 OCPD Ampere Rating 7 8 9 10 Minimum Conductor Ampacity Minimum Conductor Size Type THHN/THWN Ambient Temperature Temperature Correction Factor 11 Number of Branch Circuits Required 12 Number of Current-Carrying Conductors 13 Raceway Fill Adjustment Factor 14 15 Conductor Ampacity Before Correcting/Adjusting Conductor Ampacity After Correcting/Adjusting 1 2 4 5 Factors: • Circuits 1, 2, 3, and 4 are installed in the same raceway for a distance of 10 ft in an environment where the maximum ambient temperature will be 86°F (30°C). ⚫ Type THHN/THWN conductors shall be used for all circuits. • Minimum conductor size 12 AWG. Row 1: Calculated load in volt-amperes from problem statements. Row 2: Calculated load in amperes divided by voltage factor.
Row 2: Calculated load in amperes divided by voltage factor. Row 3: Row 4: Row 5: Load type: C = continuous; N = noncontinuous; M = motor; R = receptacle. Load modifier, 1.25 for C and M load types, 1.0 for R and N load types. Calculated load amperes (Row 2) multiplied by load modifier (Row 4). 67115 ch04_pip01_085-00998 Row 6: OCPD rating is equal to or next higher standard ampere rating than OCPD selection amperes (Row 5). Row 7: Ampacity of conductor equal to or greater than the calculated load amperes (Row 2). Row 8: Conductor size with ampacity equal to or greater than calculated load amperes (Row 2). Select from Table 310.16 using the appropriate 60°C for circuits rated 100 amperes or less, and the 75°C column for loads over 100 amperes. Row 9: From problem statements. Row 10: From NEC Table 310.15(B)(1)(1). Row 11: From load calculation. Row 12: From problem statements. Row 13: From NEC Table 310.15(C)(1). Row 14: From NEC 310.16 for conductor type specified in the problem statement: (THHN/THWN). Row 15: Value from Row 13 multiplied by correction and/or adjustment factors. This value must be equal to or greater than the minimum conductor ampacity value in Row 7. 230303 4:07 PM Complete the following table using the following circuits: 1. Eleven 120-volt duplex receptacles for general use. Receptacle loads are considered to be noncontinuous and are not subject to the 80% load limitation as applied for contin- uous loads. 2. Ten 120-volt fluorescent luminaires, rated at 150 volt-amperes each. 3. Eight 120-volt incandescent luminaires, rated at 200 watts or VA each. 4. One 240-volt exhaust fan, rated at 5000 watts or VA. 5. One 120/240-volt single-phase, 3-wire feeder, 40-kVA continuous load, originating in a room with an ambient temperature of 100°F (38°C). ROW CIRCUIT NUMBER 1 Calculated Load in Volt-Amperes Calculated Load in Amperes 2 3 Load Type 4 Load Modifier 5 OCPD Selection Amperes 6 OCPD Ampere Rating 7 8 9 10 Minimum Conductor Ampacity Minimum Conductor Size Type THHN/THWN Ambient Temperature Temperature Correction Factor 11 Number of Branch Circuits Required 12 Number of Current-Carrying Conductors 13 Raceway Fill Adjustment Factor 14 15 Conductor Ampacity Before Correcting/Adjusting Conductor Ampacity After Correcting/Adjusting 1 2 4 5 Factors: • Circuits 1, 2, 3, and 4 are installed in the same raceway for a distance of 10 ft in an environment where the maximum ambient temperature will be 86°F (30°C). ⚫ Type THHN/THWN conductors shall be used for all circuits. • Minimum conductor size 12 AWG. Row 1: Calculated load in volt-amperes from problem statements. Row 2: Calculated load in amperes divided by voltage factor.
Chapter3: Determining The Required Number Of Branch Circuits, Lighting Outlets, And Receptacle Outlets
Section: Chapter Questions
Problem 12R: How many lighting branch circuits are provided in this dwelling? __________ a. What is the minimum...
Related questions
Question
complete the table in the attached photos. instructions are below the table
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 2 steps with 4 images
Recommended textbooks for you
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:
9781337516549
Author:
Simmons
Publisher:
CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:
9781337516549
Author:
Simmons
Publisher:
CENGAGE LEARNING - CONSIGNMENT