1. A14/2 type copper used for a general lighting branch circuit.                                                Ampacity:______________              Maximum Fuse or Circuit Breakers Sizes:________________      2.Three 8 AWG copper conductors with THHN insulation Installed in garage in electrical metallic tubing (EMT). The ambient temperature in the garage can reach as high as 110'F. All termination points for this circuit are rated 60'C.                            Ampacity:______________                  Maximum Fuse or Circuit Breakers Sizes:________________ 3.Four 4 AWG copper conductor with THWN insulation imstalled in EMT in a basement. All termination points are rated at 60'C.                                 Ampacity:______________                  Maximum Fuse or Circuit Breakers Sizes:________________  4. An 8/3 Type UF copper cable installed underground from a house to a detached garage to feed a 120/240-volt subpanel. All termination points are rated at 60'C.                               Ampacity:______________                 Maximum Fuse or Circuit Breakers Sizes:_________________ 5. An electric installs five 3 AWG THWN copper current-carrying conductors in a raceway located in a garage. The garage area is subject to an ambient temperature of 100'F. All terminations are rated at 75'C.                                                                                                   Ampacity:_______________                Maximum Fuse or Circuit Breakers Sizes:________________   6. An electric rangewith a nameplate rating of 11kW.                                                                Computed load:______________kW                                                                                               Minimum conductor size for the branch circuit:________________CU                                         Maximum circuit breaker size used for the branch circuit:_________________amp 7. A counter-mounted cooktop unit with a nameplate rating of 6kW.                                        Computed load:______________kW                                                                                              Minimum conductor size for the branch circuit:________________CU.                                         Maximum circuit breaker size used for the branch circuit:_________________amp. 8.A counter-mounted cooktop unit with a nameplated rating of 4kW and a built-in oven with a nameplate rating of 8kW. Both appliances will be connected to the same branch circuit and be located in the same room.                                                                                   Computed load:___________________kW                                                                                       Minimum condutor size for the branch circuit:_________________CU                                           Maximum circuit breaker size used for the branch circuit:_________________amp

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
100%

1. A14/2 type copper used for a general lighting branch circuit.                                                Ampacity:______________              Maximum Fuse or Circuit Breakers Sizes:________________      2.Three 8 AWG copper conductors with THHN insulation Installed in garage in electrical metallic tubing (EMT). The ambient temperature in the garage can reach as high as 110'F. All termination points for this circuit are rated 60'C.                            Ampacity:______________                  Maximum Fuse or Circuit Breakers Sizes:________________ 3.Four 4 AWG copper conductor with THWN insulation imstalled in EMT in a basement. All termination points are rated at 60'C.                                

Ampacity:______________                  Maximum Fuse or Circuit Breakers Sizes:________________  4. An 8/3 Type UF copper cable installed underground from a house to a detached garage to feed a 120/240-volt subpanel. All termination points are rated at 60'C.                               Ampacity:______________                 Maximum Fuse or Circuit Breakers Sizes:_________________

5. An electric installs five 3 AWG THWN copper current-carrying conductors in a raceway located in a garage. The garage area is subject to an ambient temperature of 100'F. All terminations are rated at 75'C.                                                                                                   Ampacity:_______________                Maximum Fuse or Circuit Breakers Sizes:________________  

6. An electric rangewith a nameplate rating of 11kW.                                                                Computed load:______________kW                                                                                               Minimum conductor size for the branch circuit:________________CU                                         Maximum circuit breaker size used for the branch circuit:_________________amp

7. A counter-mounted cooktop unit with a nameplate rating of 6kW.                                        Computed load:______________kW                                                                                              Minimum conductor size for the branch circuit:________________CU.                                         Maximum circuit breaker size used for the branch circuit:_________________amp.

8.A counter-mounted cooktop unit with a nameplated rating of 4kW and a built-in oven with a nameplate rating of 8kW. Both appliances will be connected to the same branch circuit and be located in the same room.                                                                                   Computed load:___________________kW                                                                                       Minimum condutor size for the branch circuit:_________________CU                                           Maximum circuit breaker size used for the branch circuit:_________________amp

      

Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
HVDC
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,