120 kV Fig. 1 nam wzn Z= 6 + 189 110 kV Balanced 3-phase load a. W ZL ZL bem ² m b. ZL co w LOAD: 120 kVA 0.6 pf lagging my 1. For Figure 1: The 34 source on the left delivers power to a 30 load via conductors with an impedance of (6+j8) per line. The magnitude of the line-to-line voltages at the source side and at the load side are 120 and 110 kV, respectively. If the power factor of the load is 0.90 lagging, determine (a) the currents (magnitude and angle) and voltages (magnitude and angle) of the 36 load. (Hint: Voltage at the source side and the load side have given magnitude but different angles. Assume the load is Y-connected and use its Van as the reference.)

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question
120 kV
Fig. 1
m
man
man
Z=6+j82
110 kV
Balanced
3-phase
load
ZL
ZL
bw m
ZL
com ² m
LOAD:
120 kVA
0.6 pf
lagging
1. For Figure 1: The 30 source on the left delivers power to a 30 load via conductors with an impedance of (6+j8)
2 per line. The magnitude of the line-to-line voltages at the source side and at the load side are 120 and 110
kV, respectively. If the power factor of the load is 0.90 lagging, determine (a) the currents (magnitude and
angle) and voltages (magnitude and angle) of the 30 load. (Hint: Voltage at the source side and the load side
have given magnitude but different angles. Assume the load is Y-connected and use its Van as the reference.)
datumthi.
utor or
Transcribed Image Text:120 kV Fig. 1 m man man Z=6+j82 110 kV Balanced 3-phase load ZL ZL bw m ZL com ² m LOAD: 120 kVA 0.6 pf lagging 1. For Figure 1: The 30 source on the left delivers power to a 30 load via conductors with an impedance of (6+j8) 2 per line. The magnitude of the line-to-line voltages at the source side and at the load side are 120 and 110 kV, respectively. If the power factor of the load is 0.90 lagging, determine (a) the currents (magnitude and angle) and voltages (magnitude and angle) of the 30 load. (Hint: Voltage at the source side and the load side have given magnitude but different angles. Assume the load is Y-connected and use its Van as the reference.) datumthi. utor or
Expert Solution
steps

Step by step

Solved in 4 steps with 11 images

Blurred answer
Knowledge Booster
Measuring instrument
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,