P RACTICAL E XAM ON JEOL 1200EX II F OR TEM L ABORATORY C OURSE & C HECKLIST OF R EQUIREMENTS FOR U SING THE TEM U NSUPERVISED User: Date: Examiner: Users must score 100% to use the JEOL 1200EX II Unsupervised. Users can be checked out any number of times until her/his score is 100%. Scope must be used at least once a semester to maintain unsupervised status. YES NO 1. Does user know all steps, in order for starting up microscope? Pre-start Checklist : Power On, Vacuum operating at High Vacuum/Green LED Log Book Signed in LN 2 trap filled - focusing scope & viewing window covered Spot Size on 4 Bright-LED On All deflectors off (Obj-Stig, Cond-Stig Dark Tilt, Bright Tilt and Image-Shift) Condenser aperture selected Objective aperture out Intermediate aperture out Function to Mag-1 Magnification at 10,000x Room lights G G 2. Can user locate, center and saturate filament correctly? Beam Generation : Filament fully CCW Step up High Voltage Bias Set Brightness (CL#3) Set Wehnelt (Filament) Image Beam Alignment : Beam Centered, Spot 1 vs Spot 4 Lenses Cleared Gun Tilts Set Condenser Lens Stigmated Condenser Aperture Centered Filament Saturated Beam Spread CW LN 2 trap topped off G G G G 3. Can user recognize objective aperture alignment, locate and center Aperture? Beam Centered Function Diff used to located aperture Aperture centered G G
4. Can user correctly insert and remove specimens? Magnification reduced [10K or lower] Beam Spread CW Specimen trans controls centered at X=0 and Y=0,and tilt=0 E Loading Specimen Holder : Specimen rod holder used Closed forceps used to open & close securing plate Grid loaded specimen-side-down Specimen rod not touched Lint on o-ring can be removed with naked finger Inserting Sample : Rod inserted with guide pin aligned Rod pushed and held while roughing pumps starts Air lock pumped out TWO times (for tungsten) Rod turned 90 E CW to stop and rod eased into column Removing sample : Specimen trans controls centered at X=0 and Y=0,and tilt=0 E Specimen properly retrieved from column Specimen plates closed Rod returned to air lock G G G G G G G G 5. Can user correctly change between grid position 1 & 2? Magnification reduced [10K or lower] Beam Spread CW Current grid to X=0, Y=0 [Page-2] Function to Low-Mag and Mag at 120X Swing Objective Aperture out. Move from one position to the other. Return: Objective Aperture in, Function to MAG-1, converge the beam. G G 6. Can user correct Objective Lens Astigmatism G G 7. Can the user correct use the digital camera system? Camera power ON Login to workstation and start MaxIM DL 5 software CCD Temperature to > -9 C Modify Annotations to show correct Accelerating Voltage Sample image focused & stigmated Adjust Brightness to fill the screen Lift Screen before capture image Set Magnification and mag bar on image Convert to Grey Scale: Save image - Check (Contrast /Brightness change) Screen down Can Use Video window G G
8. Does user know all steps, in order for normal (stand-by) microscope shutdown? Specimen removed Filament fully CCW High Voltage to 120Kv and ON Beam Spread CW Spot Size on 4 Function to MAG-1 Magnification at 10k Digital Camera Power OFF Logged out of workstation, Mouse OFF G G 9. Does user know Full Shutdown and Startup Procedures? Full Shutdown : When is full shutdown performed? Normal / Stand-by shutdown completed High Voltage is OFF Key switched to OFF Wait (3 mins) until scope shuts down Breaker box (wall switch) to OFF Note posted stating reason for full shutdown Starting from Full Shutdown : Check that reason for full shutdown has been corrected Breaker box (wall switch) to ON Check that water recirculator is ON Turn Power Key switch to Start for 5 seconds and release Wait 45-60 minutes until Accel Voltage Ready light is Illuminated Proceed with Normal startup G G 10. Does user know correct use of Haskeris water cooling system? G G 11. Does user know the emergency procedures? G G 12. Final check list Scope CRT Bright fully CCW Counter top and Scope console organized (items returned to their places) Sample rod is in column Scope is at high vacuum Log book signed out Room lights turned off G G
Your preview ends here
Eager to read complete document? Join bartleby learn and gain access to the full version
  • Access to all documents
  • Unlimited textbook solutions
  • 24/7 expert homework help