Bundle: Refrigeration and Air Conditioning Technology, 8th + MindTap HVAC, 4 terms (24 months) Printed Access Card
8th Edition
ISBN: 9781337190350
Author: John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 43, Problem 5RQ
When is the outdoor unit called an evaporator?
A. Heating season
B. Cooling season
C. Defrost periods
D. Spring and fall seasons
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Can you solve the question by finding initial angular acceleration of D then ueing it to calculate angular velocity of D.
: +0
usão
۲/۱
العنوان
on
Jon
14.23. A double-effect forward-feed
evaporator is required to give a product
consisting of 30 per cent crystals and a
mother liquor containing 40 per cent by
mass of dissolved solids. Heat transfer
coefficients are 2.8 and 1.7 kW/m² K in the
first and second effects respectively. Dry
saturated steam is supplied at 375 kN/m²
and the condenser operates at 13.5 kN/
m².
(a) What area of heating surface is
required in each effect assuming the
effects are identical, if the feed rate is 0.6
kg/s of liquor, containing 20 per cent by
mass of dissolved solids, and the feed
temperature is 313 K?
(b) What is the pressure above the boiling
liquid in the first effect?
The specific heat capacity may be
taken as constant at 4.18 kJ/kg K. and
the effects of boiling-point rise and of
hydrostatic head may be neglected.
Example(2):
Double effect evaporator is used for
concentrating a certain caustic soda
solution 10000kg/hr from 9wt% to
47wt%. The feed at 30°C enters the
first evaporator. Backward arrangement
evaporators are used. steam is available at
167.7°C and the vapor space in the second
effect is 14.6Kpa.
The overall heat transfer coefficients of
the two effects are 8380 and 6285kcal/
W.CH
ork
-conce
-SOLFFF
and-ans..
112.1
а
DiD
3
respectively and the specific heat capacity
of all caustic soda solution 3.771 KJ/Kg.
°C, determine the heat transfer area of
each effect
معدلة 5:48 م
O
Chapter 43 Solutions
Bundle: Refrigeration and Air Conditioning Technology, 8th + MindTap HVAC, 4 terms (24 months) Printed Access Card
Ch. 43 - How does a heart pump resemble a refrigeration...Ch. 43 - Name the three common sources of heat for heat...Ch. 43 - What large line connects the indoor unit to the...Ch. 43 - Why is the indoor unit not called an evaporator?Ch. 43 - When is the outdoor unit called an evaporator? A....Ch. 43 - The indoor coil is called a condenser during...Ch. 43 - Why is it important to have drainage for the...Ch. 43 - Which metering device is most efficient in heat...Ch. 43 - Where is the only permanent suction line on a heat...Ch. 43 - What type of drier may be used in the liquid line...
Ch. 43 - Where must a suction-line drier be placed in a...Ch. 43 - What controls the heat pump to determine whether...Ch. 43 - Can a heat pump switch from heating to cooling and...Ch. 43 - What must be done when frost and ice build up on...Ch. 43 - True or False: All heat pumps are practical...Ch. 43 - Why are scroll compressors more efficient than...Ch. 43 - Describe why variable-speed compressor motors are...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- give me solution math not explinarrow_forwardgive me solution math not explinarrow_forwarduse Q Strips of material 10 mm thick are dried under constant drying conditions from 28 to 13 per cent moisture in 25 ks. The equilibrium moisture content is 7 per cent. The relation between E, the ratio of the final free moisture content at time t to the initial free moisture content, and the parameter J is given by: E 1 0.64 0.49 0.38 0.295 0.22 0.14 J 0 0.1 0.2 0.3 0.5 0.6 العنوان 0.7 It may be noted that J = kt/12, where, k = constant, t = time (ks) 1 = thickness/2 of the sheet of material (mm) a. Based on the given data, plot a graph of E against J b. Determine the time taken to dry 60 mm planks from 22 to 10 per cent moisture under the same conditions assuming no loss from the edges? ina östler ۲/۱arrow_forward
- 14.25.2.5 kg/s of a solution at 288 K containing 10 per cent of dissolved solids is fed to a forward-feed double-effect evaporator, operating at 14 kN/m² in the last effect. If the product is to consist of a liquid containing 50 per cent by mass of dissolved solids and dry saturated steam is fed to the steam coils, what PROBLEMS 1179 should be the pressure of the steam? The surface in each effect is 50 m² and the coefficients for heat transfer in the first and second effects are 2.8 and 1.7 kW/ m² K, respectively. It may be assumed that the concentrated solution exhibits a boiling-point rise of 5 deg K, that the latent heat has a constant value of 2260 kJ/kg and that the specific heat capacity of the liquid stream is constant at 3.75 kJ/kg K Oarrow_forward: +0 العنوان use only 5) A 100 kg batch of granular solids containing 30% moisture is to be dried in a tray drier to 15.5% by passing a current of air at 350 K tangentially across its surface at a velocity of 1.8 m/s. If the constant rate of drying under these conditions is 0.7 g/s m2 and the critical moisture content is 15%, calculate the approximate drying time. Assume the drying surface to be 0.03 m2 /kg dry mass. мониarrow_forwardgive me solution math not explinarrow_forward
- ۲/۱ : +0 العنوان seoni 4) 1 Mg (dry weight) of a non-porous solid is dried under constant drying conditions with an air velocity of 0.75 m/s parallel to the drying surface. The area of drying surface is 55 m2 If initial rate of drying is 0.3 g/m2 s, how long it will take to dry a material from 0.15 to 0.025 kg water/kg dry solid? The critical moisture content is 0.125 and the equilibrium moisture is negligible. The falling rate of drying is linear in moisture content. If air velocity increases to 4 m/s, what will be the anticipated saving in drying time? 0 ostherarrow_forward14.23. A double-effect forward-feed evaporator is required to give a product consisting of 30 per cent crystals and a mother liquor containing 40 per cent by mass of dissolved solids. Heat transfer coefficients are 2.8 and 1.7 kW/m² K in the first and second effects respectively. Dry saturated steam is supplied at 375 kN/m² and the condenser operates at 13.5 kN/ m². (a) What area of heating surface is required in each effect assuming the effects are identical, if the feed rate is 0.6 kg/s of liquor, containing 20 per cent by mass of dissolved solids, and the feed temperature is 313 K? (b) What is the pressure above the boiling liquid in the first effect? The specific heat capacity may be taken as constant at 4.18 kJ/kg K. and the effects of boiling-point rise and of hydrostatic head may be neglected. O Oarrow_forward5) A 100 kg batch of granular solids containing 30% moisture is to be dried in a tray drier to 15.5% by passing a current of air at 350 K tangentially across its surface at a velocity of 1.8 m/s. If the constant rate of drying under these conditions is 0.7 g/s m2 and the critical moisture content is 15%, calculate the approximate drying time. Assume the drying surface to be 0.03 m2 /kg dry mass. Oarrow_forward
- Solve for v and Iarrow_forwardG = 0.350MPa, P = 900N, a=20mm, b=50mm, c=80mmarrow_forward[20 Points] Use Method of Sections to draw the shear-force and bending-moment diagrams for the simply supported beam shown. Determine the maximum bending moment that occurs in the span. 1.5 kN/m 4 m 2 m Carrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage LearningAutomotive Technology: A Systems Approach (MindTa...Mechanical EngineeringISBN:9781133612315Author:Jack Erjavec, Rob ThompsonPublisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
Automotive Technology: A Systems Approach (MindTa...
Mechanical Engineering
ISBN:9781133612315
Author:Jack Erjavec, Rob Thompson
Publisher:Cengage Learning
Hydronics Step by Step; Author: Taco Comfort Solutions;https://www.youtube.com/watch?v=-XGNl9kppR8;License: Standard Youtube License