14.23. A double-effect forward-feed evaporator is required to give a product consisting of 30 per cent crystals and a mother liquor containing 40 per cent by mass of dissolved solids. Heat transfer coefficients are 2.8 and 1.7 kW/m² K in the first and second effects respectively. Dry saturated steam is supplied at 375 kN/m² and the condenser operates at 13.5 kN/ m². (a) What area of heating surface is required in each effect assuming the effects are identical, if the feed rate is 0.6 kg/s of liquor, containing 20 per cent by mass of dissolved solids, and the feed temperature is 313 K? (b) What is the pressure above the boiling liquid in the first effect? The specific heat capacity may be taken as constant at 4.18 kJ/kg K. and the effects of boiling-point rise and of hydrostatic head may be neglected. O O

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter47: High-pressure, Low-pressure, And Absorption Chilled-water Systems
Section: Chapter Questions
Problem 13RQ: The subcooling temperature in a condenser can be measured by taking the difference between the A....
icon
Related questions
Question
14.23. A double-effect forward-feed
evaporator is required to give a product
consisting of 30 per cent crystals and a
mother liquor containing 40 per cent by
mass of dissolved solids. Heat transfer
coefficients are 2.8 and 1.7 kW/m² K in the
first and second effects respectively. Dry
saturated steam is supplied at 375 kN/m²
and the condenser operates at 13.5 kN/
m².
(a) What area of heating surface is
required in each effect assuming the
effects are identical, if the feed rate is 0.6
kg/s of liquor, containing 20 per cent by
mass of dissolved solids, and the feed
temperature is 313 K?
(b) What is the pressure above the boiling
liquid in the first effect?
The specific heat capacity may be
taken as constant at 4.18 kJ/kg K. and
the effects of boiling-point rise and of
hydrostatic head may be neglected.
O
O
Transcribed Image Text:14.23. A double-effect forward-feed evaporator is required to give a product consisting of 30 per cent crystals and a mother liquor containing 40 per cent by mass of dissolved solids. Heat transfer coefficients are 2.8 and 1.7 kW/m² K in the first and second effects respectively. Dry saturated steam is supplied at 375 kN/m² and the condenser operates at 13.5 kN/ m². (a) What area of heating surface is required in each effect assuming the effects are identical, if the feed rate is 0.6 kg/s of liquor, containing 20 per cent by mass of dissolved solids, and the feed temperature is 313 K? (b) What is the pressure above the boiling liquid in the first effect? The specific heat capacity may be taken as constant at 4.18 kJ/kg K. and the effects of boiling-point rise and of hydrostatic head may be neglected. O O
AI-Generated Solution
AI-generated content may present inaccurate or offensive content that does not represent bartleby’s views.
steps

Unlock instant AI solutions

Tap the button
to generate a solution

Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning
Principles of Heat Transfer (Activate Learning wi…
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning