high-pressure condenser is at 1514.2 kPa. The cascade condenser Determine (a) the mass flow rate in the low-pressure loop, (b) required, (d) the COP, and (e) the quantity of the fluid entering PROBLEMS (1) Atwo-stage cascade refrigeration'system uses ammonia the working substance. The evaporator is at -35°C and the bigh-pressure condenser is at 1514.2 kPa. The cascade condenser is a direct-contract type. The refrigeration load is 90 tons. Determine (a) the mass flow rate in the low-pressure loop, (b) the mass flow rate in the high-pressure loop, (c) the power as the evaporator. Ans. (a) 0.2572 kg/s, (b) 0.341 kg/s, (c) 116.08 kW, (d) 2.73, (e) 10.37%
high-pressure condenser is at 1514.2 kPa. The cascade condenser Determine (a) the mass flow rate in the low-pressure loop, (b) required, (d) the COP, and (e) the quantity of the fluid entering PROBLEMS (1) Atwo-stage cascade refrigeration'system uses ammonia the working substance. The evaporator is at -35°C and the bigh-pressure condenser is at 1514.2 kPa. The cascade condenser is a direct-contract type. The refrigeration load is 90 tons. Determine (a) the mass flow rate in the low-pressure loop, (b) the mass flow rate in the high-pressure loop, (c) the power as the evaporator. Ans. (a) 0.2572 kg/s, (b) 0.341 kg/s, (c) 116.08 kW, (d) 2.73, (e) 10.37%
Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
Related questions
Question
![high-pressure condenser is at 1514.2 kPa. The cascade condenser
< Refrigeration by Sta. Maria(1)
11:57 MOn.
Copy Share
Refrigeration and Áir Buiditioning 97
PROBLEMS
(1) Atwo-stage cascade refrigeration'system uses ammonia
e the working substance. The evaporator is at -35°C and the
is a direct-contract type. The refrigeration load is 90 tons.
Determine (a) the mass flow rate in the low-pressure loop, (b)
the mass flow rate in the high-pressure loop, (c) the power
required, (d) the COP, and (e) the quantity of the fluid entering
the evaporator.
Ans. (a) 0.2572 kg/s, (b) 0.341 kg/s,
(c) 116.08 kW, (d) 2.73, (e) 10.37%
II](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2F954549f0-5cf4-4c2b-bc85-330e9a9b2bc2%2F7f25e1a4-52d7-4c2f-b53c-9fbc6004c1ae%2F4ex7118_processed.jpeg&w=3840&q=75)
Transcribed Image Text:high-pressure condenser is at 1514.2 kPa. The cascade condenser
< Refrigeration by Sta. Maria(1)
11:57 MOn.
Copy Share
Refrigeration and Áir Buiditioning 97
PROBLEMS
(1) Atwo-stage cascade refrigeration'system uses ammonia
e the working substance. The evaporator is at -35°C and the
is a direct-contract type. The refrigeration load is 90 tons.
Determine (a) the mass flow rate in the low-pressure loop, (b)
the mass flow rate in the high-pressure loop, (c) the power
required, (d) the COP, and (e) the quantity of the fluid entering
the evaporator.
Ans. (a) 0.2572 kg/s, (b) 0.341 kg/s,
(c) 116.08 kW, (d) 2.73, (e) 10.37%
II
Expert Solution
![](/static/compass_v2/shared-icons/check-mark.png)
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 4 steps with 4 images
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
![Elements Of Electromagnetics](https://www.bartleby.com/isbn_cover_images/9780190698614/9780190698614_smallCoverImage.gif)
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
![Mechanics of Materials (10th Edition)](https://www.bartleby.com/isbn_cover_images/9780134319650/9780134319650_smallCoverImage.gif)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
![Thermodynamics: An Engineering Approach](https://www.bartleby.com/isbn_cover_images/9781259822674/9781259822674_smallCoverImage.gif)
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
![Elements Of Electromagnetics](https://www.bartleby.com/isbn_cover_images/9780190698614/9780190698614_smallCoverImage.gif)
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
![Mechanics of Materials (10th Edition)](https://www.bartleby.com/isbn_cover_images/9780134319650/9780134319650_smallCoverImage.gif)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
![Thermodynamics: An Engineering Approach](https://www.bartleby.com/isbn_cover_images/9781259822674/9781259822674_smallCoverImage.gif)
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
![Control Systems Engineering](https://www.bartleby.com/isbn_cover_images/9781118170519/9781118170519_smallCoverImage.gif)
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
![Mechanics of Materials (MindTap Course List)](https://www.bartleby.com/isbn_cover_images/9781337093347/9781337093347_smallCoverImage.gif)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
![Engineering Mechanics: Statics](https://www.bartleby.com/isbn_cover_images/9781118807330/9781118807330_smallCoverImage.gif)
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY