In NH3-water absorption system the heat is supplied to generator by condensing stream at 0.2 MPa. The initial state of the stream is at a dryness fraction of 0.9 and the final state of stream after condensing is saturated liquid. This temperature to be maintained in refrigerator is -10°C and surrounding temperature is 30°C. If relative efficiency is 0.4 and refrigeration load is 20 TR. The steam flow rate is kg/s. [Given: At 0.2 MPa, Tsat = 120°C and hfg=2201.9 kJ/kg]
In NH3-water absorption system the heat is supplied to generator by condensing stream at 0.2 MPa. The initial state of the stream is at a dryness fraction of 0.9 and the final state of stream after condensing is saturated liquid. This temperature to be maintained in refrigerator is -10°C and surrounding temperature is 30°C. If relative efficiency is 0.4 and refrigeration load is 20 TR. The steam flow rate is kg/s. [Given: At 0.2 MPa, Tsat = 120°C and hfg=2201.9 kJ/kg]
Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
Related questions
Question
![In NH3-water absorption system the heat is supplied to generator by condensing stream at 0.2 MPa. The initial state of the stream is at a
dryness fraction of 0.9 and the final state of stream after condensing is saturated liquid. This temperature to be maintained in refrigerator is
-10°C and surrounding temperature is 30°C. If relative efficiency is 0.4 and refrigeration load is 20 TR. The steam flow rate is ________ kg/s.
[Given: At 0.2 MPa, Tsat = 120°C and hfg=2201.9 kJ/kg]](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2Fa788b7e8-9fcc-4034-bad1-c785839bf30e%2F27287285-5bd9-4546-a00a-e6850420d841%2Fl4jbzdx_processed.jpeg&w=3840&q=75)
Transcribed Image Text:In NH3-water absorption system the heat is supplied to generator by condensing stream at 0.2 MPa. The initial state of the stream is at a
dryness fraction of 0.9 and the final state of stream after condensing is saturated liquid. This temperature to be maintained in refrigerator is
-10°C and surrounding temperature is 30°C. If relative efficiency is 0.4 and refrigeration load is 20 TR. The steam flow rate is ________ kg/s.
[Given: At 0.2 MPa, Tsat = 120°C and hfg=2201.9 kJ/kg]
Expert Solution

This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 2 steps with 4 images

Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you

Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press

Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON

Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education

Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press

Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON

Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education

Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY

Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning

Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY