Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN: 9780133923605
Author: Robert L. Boylestad
Publisher: PEARSON
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 4, Problem 57P
The motor used on a conveyor belt is 85% efficient. If the overall efficiency is 75%, what is the efficiency of the conveyor belt assembly?
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
This is the 3rd time i'm asking this. SOLVE THIS AND FIND V0 , the last answer i was given is -2V which is not even one of the listed options. the listed options are: 12V,4V,24V,6V. first answer given to me was 4V but after i simulated on ltspice albeit i'm not sure if i simulated correct i got a different answer and when i solved it myself i got a different answer. this is my last remaining question. PLEASE SOLVE CORRECTLY AND PROPERLY. NODAL ANALYSIS IS BEST TO USE HERE. IT IS AN IDEAL OP-AMP. SIMULATE USING LTSPICE AND GIVE ME FINAL ANSWER IF POSSIBLE AS THAT IS ALL I CARE ABOUT NOT THE PROCESS. THANK YOU. WILL UPVOTE CORRECT ANSWER, but downvote wrong answer.
Find the exact value of V0. This question was already asked here and the answer was 4V i solved it myself and got a different answer and when i simulated it i also got a different answer.But i might be wrong. so please solve this for me and IF POSSIBLE simulate it so we can be 100% sure that the answer is correct as it's very important that i understand where i went wrong.
Find load flow Solution
1.2 20
Z12 = 0.01+jo.03 in
Z₁4=0.02+0.04
и
а
9.01+10.03
0.02+0.04 0.01+0.03
58-1
Vek 1.05
100 MVA
Pe=230 MW
150 MW w
140 MW
01012 +0.035
80 M√ar
723=0.01+0.03 90 mvare
Z34 = 0.012+ 10.035
Chapter 4 Solutions
Introductory Circuit Analysis (13th Edition)
Ch. 4 - What is the voltage across a 220 resistor if the...Ch. 4 - What is the current through a 2.20 resistor if the...Ch. 4 - How much resistance is required to limit the...Ch. 4 - At starting, what is the current drain on a 12 V...Ch. 4 - If the current through a 100k resistor is 3.6A...Ch. 4 - If a voltmeter has an internal resistance of 50k...Ch. 4 - If a refrigerator draws 2.2 A at 120 V, what is...Ch. 4 - If a clock has an internal resistance of 8k find...Ch. 4 - A washing machine is rated at 4.2 A at 120 V. What...Ch. 4 - A CD player draws 80 mA when 4.5 V is applied....
Ch. 4 - The input current to a transistor is 20A If the...Ch. 4 - Prob. 12PCh. 4 - If an electric heater draws 9.5 A when connected...Ch. 4 - In a TV camera, a current of 5.6 mA passes through...Ch. 4 - Plot the curve of I (vertical axis) versus...Ch. 4 - Plot the I-V curve for a 5 and a 20 resistor on...Ch. 4 - Prob. 17PCh. 4 - Sketch the internal resistance characteristics of...Ch. 4 - Plot the I-V characteristics of a 1k,10k, and a 1M...Ch. 4 - If 540 J of energy are absorbed by a resistor in...Ch. 4 - The power to a device is 40 joules per second...Ch. 4 - How many joules of energy does a 8 W nightlight...Ch. 4 - How long must a steady current of 1.4 A exist in a...Ch. 4 - What is the power delivered by a 12 V battery if...Ch. 4 - The current through a 4k resistor is 7.2 mA. What...Ch. 4 - The power consumed by a 2.2k resistor is 240 mW....Ch. 4 - What is the maximum permissible current in a 82,...Ch. 4 - The voltage drop across a transistor network is 22...Ch. 4 - If the power applied to a system is 10 kW, what is...Ch. 4 - A 1 W resistor has a resistance of 4.7M . What is...Ch. 4 - A 2.2k resistor in a stereo system dissipates 42...Ch. 4 - What are the hot resistance level and current...Ch. 4 - What are the internal resistance and voltage...Ch. 4 - A calculator with an internal 3 V battery draws...Ch. 4 - A 20k resistor has a rating of 100 W. What are the...Ch. 4 - What is the total horsepower rating of a series of...Ch. 4 - A 10 resistor is connected across a 12 V battery....Ch. 4 - How much energy in kilowatthours is required to...Ch. 4 - How long can a 1500 W heater be on before using...Ch. 4 - A 60 W bulb is on for 10 h. a. What is the energy...Ch. 4 - In 10 h an electrical system converts 1200 kWh of...Ch. 4 - At 12/kWh how long can you play a 250 W color...Ch. 4 - The electric bill for a family for a month is...Ch. 4 - How long can you use an Xbox 360 for $1 if it uses...Ch. 4 - The average plasma screen TV draws 339 W of power,...Ch. 4 - The average PC draws 78 W. What is the cost of...Ch. 4 - If a house is supplied with 120 V, 100 A service,...Ch. 4 - What is the total cost of using the following at...Ch. 4 - What is the total cost of using the following at...Ch. 4 - Prob. 50PCh. 4 - The motor of a power saw is rated 72% efficient....Ch. 4 - What is the efficiency of a dryer motor that...Ch. 4 - A stereo system draws 1.8 A at 120 V. The audio...Ch. 4 - Prob. 54PCh. 4 - Prob. 55PCh. 4 - An electric motor used in an elevator system has...Ch. 4 - The motor used on a conveyor belt is 85%...Ch. 4 - Prob. 58PCh. 4 - The overall efficiency of two systems in cascade...Ch. 4 - What is the total efficiency of three systems in...Ch. 4 - If the total input and output power of two systems...Ch. 4 - Using PSpice 0r Multisim, repeat the analysis of...Ch. 4 - Using PSpice or Multisim, repeat the analysis of...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- SD = 100 MVA 1.12° 150mw ← 0.01+0.03 10.02 -0.04 Too M P = 250 MW 0.02+0.04 0.012 jo.03 $ (V3)=1.05 P.4 -03 = = 200 MW 212=0.01+10.03 Zzze 0.02 +10.04 214=0.02+10.04 Z34 = 0.012+10.03arrow_forwardChoose the correct answer to the following questions: 1- What is the total power radiated in Watts for the power density W = a) 4π² b) 8m²/3 2- Fresnel zone is also called as sine W/m²? 3r² c) 4π²/3 d) 2π²/3 a) Near Field b) Far Field c) Electrostatic Field d) Reactive Field 3- The far-field distance at 900 MHz, if the maximum antenna dimension is 0.75 m is.... a) 3.375 m b) 3.5m c) 3.375 cm d) none 4- The antenna gain is on input power to antenna and on power due to ohmic losses. c) Independent, dependent d) a) Independent, independent b) Dependent, independent Dependent, dependent 5- If beam width of the antenna increases, then directivity. a) Decreases b) Increases c) Remains unchanged d) Depends on type of antennaarrow_forwardplease solve this and clarify each step. thanksarrow_forward
- The input reactance of 1/2 dipole with radius of 1/30 is given as shown in figure below, Assuming the wire of dipole is conductor 5.6*107 S/m, determine at f=1 GHz the a- Loss resistance, b- Radiation efficiency c- Reflection efficiency when the antenna is connected to T.L shown in the figure. Rr Ro= 50 2 Avg/4 RL -j100 [In(l/a) 1.5] tan(ẞ1)arrow_forwardFind Zeq here. i already had one solution written to me but it's wrong. my main question is. i know that i do the parallel connection first so 2x2 / 2+2 = 1ohm but what i'm asking is since it's an open terminal is R3,2(parallel resistors) in series to R1? or should i first do R3,2 // to ZL and then add R1 in series? PLEASE READ THIS. and solve properly. EXPLAIN WHAT I ASKED PROPERLY. UPVOTE WILL BE GIVEN.arrow_forwardThe E-field pattern of an antenna, independent of o, varies as follows: E = 0 7100 0° ≤0≤45° 45° < 0 ≤ 90° 90° < 0 ≤ 180° (a) What is the directivity of this antenna? (b) What is the radiation resistance of the antenna at 200 m from it if the field is equal to 10 V/m (rms) for 0 = 0° at that distance and the terminal current is 5 A (rms)?arrow_forward
- Find Zeq here. i already had one solution written to me but it's wrong. my main question is. i know that i do the parallel connection first so 2x2 / 2+2 = 1ohm but what i'm asking is since it's an open terminal is R3,2(parallel resistors) in series to R1? or should i first do R3,2 // to ZL and then add R1 in series? PLEASE READ THIS. and solve properly. EXPLAIN WHAT I ASKED PROPERLY. UPVOTE WILL BE GIVEN.arrow_forwardFind Zeq here, ignore the semi circle in the wiring i'm just bad at drawing circuits. ZL=JWL write Zeq in terms of JW and give me the final equation. (basically check the parallel and series combinations and give me the final answer.)Will upvote correct answer. Thanks!arrow_forwardFill in the chart and answer questions Answer problems 10, 11, and 12 using the following information:An addition is being planned to a school building. You have been asked to determine theload that will be added to the panelboard that will serve this addition.The addition will be a building 80 ft 3 50 ft. It will consist of four classrooms, every40 ft 3 20 ft and a corridor that is 10-ft wide The following loads will be installed:Each classroom:12 fluorescent luminaires, 2 ft 3 4 ft @ 85 VA each20 duplex receptaclesAC unit, 208-volt, 1-phase @ 5000 VACorridor:5 fluorescent luminaires, 1 ft 3 8 ft @ 85 VA each8 duplex receptaclesExterior:4 wall-mounted luminaires @ 125 VA each4 duplex receptacles 10. The calculated load is__________ VA.11. The connected load is__________ VA.12. The neutral load is_____________ VA.arrow_forward
- A 1200-ampere service was installed, consisting of three sets of 600 kcmil THHN/THWN copper conductors per phase. The electrical contractor was careful to cut theconductors the same length. When the utility crew made up the connections at theservice heads, they cut the conductors to different lengths to make their connectionssimpler. The actual lengths of the service-entrance conductors in a given phase ended up being20 ft (6.1 m), 22 ft (6.7 m), and 24 ft (7.3 m). The maximum ampacity of a 600-kcmilTHHN/THWN copper conductor is 420 amperes using the 75°C column of Table310.16. This is more than adequate for the calculated 1200 amperes when three conductors are run in parallel. Determine how the load of 1200 amperes would divide in each of the three paralleledconductors in a phase.arrow_forwardDetermine the conductor sizes for a feeder to a panelboard. It is a 120/240-volt,single-phase system. The OCPD has a rating of 100 amperes. The calculated load is15,600 VA. All the loads are 120 volts.arrow_forwardCalculate the neutral current in a 120/240-volt, single-phase system when the current inphase A is 20 amperes and the current in phase B is 40 amperes. The load is resistive. Calculate the neutral current in a 208Y/120-volt, 3-phase, 4-wire system when thecurrent in phase A is 0, in phase B is 40, and in phase C is 60 amperes. The load isresistivearrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Delmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningElectricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
What is an electric furnace and how does it work?; Author: Fire & Ice Heating and Air Conditioning Inc;https://www.youtube.com/watch?v=wjAWecPGi0M;License: Standard Youtube License