Question
Chapter 3, Problem 1R
To determine
Explain the meaning of calculated load.
Expert Solution & Answer
Explanation of Solution
Discussion:
The equivalent value of all the loads connected to a system is said to be calculated load. The power rating of loads differs for different applications. It is also defined as the estimated load for the nominal values.
According to article NEC 220, the calculations for branch circuit, feeder, and service load are made. When all the loads are considered with the proper multipliers, the calculated load is the final result that provides guidance to calculate various types of load. To calculate the loads, both the optimal and standard methods are provided.
Conclusion:
Thus, the meaning of calculated load is explained.
Want to see more full solutions like this?
Subscribe now to access step-by-step solutions to millions of textbook problems written by subject matter experts!
Students have asked these similar questions
How Rth connected with the load resistance, explain.
What is ampere circuital law?
Explain the advantage and disadvantage of Power Grid Extension
Chapter 3 Solutions
ELECTRICAL WIRING:RESIDENTAL-6 PLANS
Ch. 3 - Prob. 1RCh. 3 - How are branch circuits rated? See NEC 210.3._____Ch. 3 - Prob. 3RCh. 3 - Prob. 4RCh. 3 - What spaces are not included in the floor area...Ch. 3 - What is the unit load per square foot for dwelling...Ch. 3 - According to NEC 210.50(C), a laundry equipment...Ch. 3 - How is the total load in volt-amperes for lighting...Ch. 3 - How is the total lighting load in amperes...Ch. 3 - How is the required number of branch circuits...
Ch. 3 - What is the minimum number of 15-ampere lighting...Ch. 3 - How many lighting branch circuits are provided in...Ch. 3 - Prob. 13RCh. 3 - How is the load determined for outlets supplying...Ch. 3 - What type of circuits must be provided for...Ch. 3 - Prob. 16RCh. 3 - In a single-family dwelling, how is overcurrent...Ch. 3 - Prob. 18RCh. 3 - The minimum number of outdoor receptacles for a...Ch. 3 - The Code indicates the rooms in a dwelling that...Ch. 3 - Prob. 21RCh. 3 - Prob. 22RCh. 3 - Prob. 23RCh. 3 - Prob. 24RCh. 3 - Prob. 25RCh. 3 - Although the Code contains many exceptions to the...Ch. 3 - The rating of a branch circuit is based on (Circle...Ch. 3 - a. A 25-ampere branch-circuit conductor is derated...Ch. 3 - Prob. 29RCh. 3 - Prob. 30RCh. 3 - Prob. 31RCh. 3 - Prob. 32RCh. 3 - A split-level home has one stairway that has six...Ch. 3 - Prob. 34RCh. 3 - Prob. 35RCh. 3 - Prob. 36RCh. 3 - In the past, it was common practice to connect the...Ch. 3 - If a residence has two bathrooms, the Code states:...Ch. 3 - Prob. 39RCh. 3 - Prob. 40RCh. 3 - Prob. 41RCh. 3 - Prob. 42RCh. 3 - Prob. 43R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- 7. Describe the direct connection, series and parallel methods of measurements using Q-meters? Why and how do we use these methods, explain in brief.arrow_forwardDefine the terms "load shedding" and "voltage regulation" in the context of power systems. How do these aspects impact the stability and reliability of an electrical grid?arrow_forwardVoltage sags due to short circuit and earth faults are the cause for the vast majority of equipment problems. Electronics equipment become more susceptible to voltage sag, hence the companies experience production stoppages. Voltage sag analysis is very complex issue. Based on voltage sag randon factors describe on it.arrow_forward
- A power generation plant connected to bulk load of high voltage industries shown in Figure Q3 has specifications given in Table Q3. Each equipment reactance is expressed in per unit on a common base of 100 MVA. a) Find the fault level for each bus bar in the generation plant. GI G2 TI Figure Q3: Single line diagram of a power generation plant Table Q3: Specifications of power system components Power System Component Voltage Rating X MVA Rating (kV) (pu) GI 50 33 0.2 G2 40 33 0.18 50 33/11 0.1 T2 40 33/11 0.1arrow_forwardQuestion 1:a) State why voltage control and cable stranding are necessary in powersystemsb) Briefly explain where and how the following state variables ofa power supply grid are controlled.i) Frequencyii) Active powerili) Reactive poweriv Voltage.arrow_forwardWhich of the following Surge Diverter use non-linear resistances in its fabrication? Rod - Gape SD. Lightning Arrester SD. Expulsion Tube SD. O All of the above.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT