Principles of Instrumental Analysis
7th Edition
ISBN: 9781305577213
Author: Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Question
Chapter 29, Problem 29.10QAP
Interpretation Introduction
Interpretation:
The recovery process of analytes after an SFE is to be discussed.
Concept introduction:
When there is a use of supercritical fluid as an extracting solvent, the extraction process is termed as the supercritical fluid extraction method.
This type of extraction method is applied for separating essential oils, flavors, fat and other ingredients from the mixtures.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
analyte
concentration(C)(mg/ml)
injection volume (ul)
elution time (time)
peak DAD signal(mAU)
caffeine
1
1
4.67
302.85
aspartame
5
1
7.53
15.83
benzoic acid
1
1
8.14
89.98
saccharin
1
1
1.91
84.86
mixture(add everything above with 1:1:1:1 ratio)
1
4.47
69.58
How to get the concentration of the mixture in this case?
What can labs do to reduce error in GC- ms??
PLEASE Answer within 20-30 minutes. Thank you!
Knowledge Booster
Similar questions
- Suppose that a lead determination has a standard deviation of 3 mg. If the sample has a mean value of 60 mg, the CV is 5%. For a sample containing only 15 mg, the CV isarrow_forward■ True or False: in a TOF analyzer, a fragment of low mass reaches the detector first ▪ In GCMS when we know what analytes we are measuring we use not know what analytes are in the sample we use than scan. ▪ A) Scan; SIM ■ B)SIM; scan • C) SIM; SIM mode. When we do mode. SIM allows greater sensitivityarrow_forwardIf Jotaro Kujo measured the amount of current that passes through a sample to measure the amount of analyte in the sample, what kind of method did he use? Volumetric method Spectroscopic method Gravimetric method Electroanalytical methodarrow_forward
- #19 & 23arrow_forward1) Titrant 5 mg H2O/ mL Resolution 2.5 µg H2O/step Detection limit is 125 µg H2O for a 5 g sample (= 25 ppm) 2) Titrant 2 mg H2O/ mL Resolution 1 µg H2O/step Detection limit is 50 µg H2O for a 5 g sample (= 10 ppm) You have a 10 g sample which is expected to contain 200 µg H2O. True or false? 1. Titrant 5mg/mL is the preferred system over 2. Titrant 2mg/mL for this sample. True Falsearrow_forwardwhat is the concentration of the unknown sample using serial diluitions: 0.05M 1.7472nm, 0.025M 0.8569nm, 0.0125M 0.4167nm, 0.00625M 0.1958nm the epsilon value is 0.0101 and l is 1 cmarrow_forward
- A sample of explosives residue is dissolved in an appropriate solvent and is injected into HPLC. The column contains a non- polar stationary phase. The sample revealed three chemical compounds that are commonly present in homemade explosives. ТAТP DADP HMTD 1 2 3 4 5 6 7 8 Retention time (minutes) a) determine the retention time of TATP. b) which one elute first :DADP,TATP or HMTD? c) State and explain which compound is most polar. d) If you are investigating this terrorist attacks, state one way in which the information in the chromatogram would be useful.arrow_forwardWhat is the retention factor (Rf) of the most polar and least polar spot present in the standard ink? (Use 2 significant figures)arrow_forwardData Collection Kinetic Data Collection Time, t (s) Volume of added base (mL) First addition 40 0.50 Second addition 101 1.00 Third addition 160 1.52 Fourth addition 224 1.99 Fifth addition 278 2.49 Sixth addition 334 3.01 Seventh additlon 389 3.48 Calculations Concentration of NaOH stock solution: 0.01 M Concentration of t-BuCl stock solution: 0.2 M Volume of t-BuCl solution: 10 mL stock stock solution added to 25 mL acetone Table view List view Kinetic Data Volume of Moles of Amount of t-Bucl (mol) [-Buc] In[-BuC Time, t (s) added base added base (mL) (mol) First addition 40 0.50 Second additlon 101 1.00 Third addition 160 1.52 Fourth addition 224 1.99 Flfth additlon 278 2.49 Sixth additlon 334 3.01 Seventh addition 389 3.48 Use the data in the table above to plot In[t-BuC]]; vs time (s). Include labelled axis, a title, and a linear trendline. Upload your plot here.arrow_forward
- What is the percent error of the Ksp of Ca(OH)2 if the experimental value is 9.1 x 10^-5 and the accepted value is 5.5 x 10^-6?arrow_forwardHello please help with number 4.arrow_forwardII. b) What is the difference between liquid-liquid, solid-liquid and solid-phase extraction? Complete the table below and sort the following examples in the correct column: Steeping tea, washing an organic phase (workup), brewing beer, chemical desalting of crude oil, activated carbon sugar decolorization. liquid-liquid solid-liquid solid-phase Phase that contains analyte before extraction? Phase that contains analyte after extraction? Example(s)arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- General, Organic, and Biological ChemistryChemistryISBN:9781285853918Author:H. Stephen StokerPublisher:Cengage LearningOrganic And Biological ChemistryChemistryISBN:9781305081079Author:STOKER, H. Stephen (howard Stephen)Publisher:Cengage Learning,Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
General, Organic, and Biological Chemistry
Chemistry
ISBN:9781285853918
Author:H. Stephen Stoker
Publisher:Cengage Learning
Organic And Biological Chemistry
Chemistry
ISBN:9781305081079
Author:STOKER, H. Stephen (howard Stephen)
Publisher:Cengage Learning,
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning