(a)
Interpretation:
The kind of analytes respond for given liquid chromatography detector has to be found.
Ultra violet
Concept introduction:
Detector: The detector used in high performance liquid chromatography is to detect individual component from the mixture being eluted from the chromatography column.
The role of detector is convert the effluents to electric signal which is recorded by recorder.
The detector used in the liquid chromatography are,
- Ultraviolet
- Evaporative light scattering
- Refractive index
Electrochemical - Fluorescence
- Conductivity
- Nitrogen chemiluminescence
(b)
Interpretation:
The kind of analytes respond for given liquid chromatography detector has to be found.
Refractive index
Concept introduction:
Detector: The detector used in high performance liquid chromatography is to detect individual component from the mixture being eluted from the chromatography column.
The role of detector is convert the effluents to electric signal which is recorded by recorder.
The detector used in the liquid chromatography are,
- Ultraviolet
- Evaporative light scattering
- Refractive index
- Electrochemical
- Fluorescence
- Conductivity
- Nitrogen chemiluminescence
(c)
Interpretation:
The kind of analytes respond for given liquid chromatography detector has to be found.
Evaporative light scattering
Concept introduction:
Detector: The detector used in high performance liquid chromatography is to detect individual component from the mixture being eluted from the chromatography column.
The role of detector is convert the effluents to electric signal which is recorded by recorder.
The detector used in the liquid chromatography are,
- Ultraviolet
- Evaporative light scattering
- Refractive index
- Electrochemical
- Fluorescence
- Conductivity
- Nitrogen chemiluminescence
(d)
Interpretation:
The kind of analytes respond for given liquid chromatography detector has to be found.
Charged aerosol
Concept introduction:
Detector: The detector used in high performance liquid chromatography is to detect individual component from the mixture being eluted from the chromatography column.
The role of detector is convert the effluents to electric signal which is recorded by recorder.
The detector used in the liquid chromatography are,
- Ultraviolet
- Evaporative light scattering
- Refractive index
- Electrochemical
- Fluorescence
- Conductivity
- Nitrogen chemiluminescence
(e)
Interpretation:
The kind of analytes respond for given liquid chromatography detector has to be found.
Electrochemical
Concept introduction:
Detector: The detector used in high performance liquid chromatography is to detect individual component from the mixture being eluted from the chromatography column.
The role of detector is convert the effluents to electric signal which is recorded by recorder.
The detector used in the liquid chromatography are,
- Ultraviolet
- Evaporative light scattering
- Refractive index
- Electrochemical
- Fluorescence
- Conductivity
- Nitrogen chemiluminescence
(f)
Interpretation:
The kind of analytes respond for given liquid chromatography detector has to be found.
Fluorescence
Concept introduction:
Detector: The detector used in high performance liquid chromatography is to detect individual component from the mixture being eluted from the chromatography column.
The role of detector is convert the effluents to electric signal which is recorded by recorder.
The detector used in the liquid chromatography are,
- Ultraviolet
- Evaporative light scattering
- Refractive index
- Electrochemical
- Fluorescence
- Conductivity
- Nitrogen chemiluminescence
(g)
Interpretation:
The kind of analytes respond for given liquid chromatography detector has to be found.
Nitrogen chemiluminescence
Concept introduction:
Detector: The detector used in high performance liquid chromatography is to detect individual component from the mixture being eluted from the chromatography column.
The role of detector is convert the effluents to electric signal which is recorded by recorder.
The detector used in the liquid chromatography are,
- Ultraviolet
- Evaporative light scattering
- Refractive index
- Electrochemical
- Fluorescence
- Conductivity
- Nitrogen chemiluminescence
(h)
Interpretation:
The kind of analytes respond for given liquid chromatography detector has to be found.
Conductivity
Concept introduction:
Detector: The detector used in high performance liquid chromatography is to detect individual component from the mixture being eluted from the chromatography column.
The role of detector is convert the effluents to electric signal which is recorded by recorder.
The detector used in the liquid chromatography are,
- Ultraviolet
- Evaporative light scattering
- Refractive index
- Electrochemical
- Fluorescence
- Conductivity
- Nitrogen chemiluminescence

Want to see the full answer?
Check out a sample textbook solution
Chapter 25 Solutions
Quantitative Chemical Analysis 9e And Sapling Advanced Single Course For Analytical Chemistry (access Card)
- Use diagram to answer the following: 1.Is the overall rxn endo- or exothermic. Explain briefly your answer____________________2. How many steps in this mechanism?_____________3. Which is the rate determining step? Explain briefly your answer____________________4. Identify (circle and label) the reactants,the products and intermediate (Is a Cation, Anion, or a Radical?) Please explain and provide full understanding.arrow_forwardDraw the entire mechanism and add Curved Arrows to show clearly how electrons areredistributed in the process. Please explain and provide steps clearly.arrow_forward15) Create Lewis structure Br Brarrow_forward
- LIOT S How would you make 200. mL of a 0.5 M solution of CuSO4 5H2O from solid copper (II) sulfate? View Rubricarrow_forwardSteps and explantions pleasearrow_forwardMatch the denticity to the ligand. Water monodentate ✓ C₂O2 bidentate H₂NCH₂NHCH2NH2 bidentate x EDTA hexadentate Question 12 Partially correct Mark 2 out of 2 Flag question Provide the required information for the coordination compound shown below: Na NC-Ag-CN] Number of ligands: 20 Coordination number: 2✔ Geometry: linear Oxidation state of transition metal ion: +3 x in 12 correct out of 2 question Provide the required information for the coordination compound shown below. Na NC-Ag-CN] Number of ligands: 20 Coordination number: 2 Geometry: linear 0 Oxidation state of transition metal ion: +3Xarrow_forward
- Can you explain step by step behind what the synthetic strategy would be?arrow_forwardPlease explain step by step in detail the reasoning behind this problem/approach/and answer. thank you!arrow_forward2. Predict the product(s) that forms and explain why it forms. Assume that any necessary catalytic acid is present. .OH HO H₂N OHarrow_forward
- ChemistryChemistryISBN:9781305957404Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCostePublisher:Cengage LearningChemistryChemistryISBN:9781259911156Author:Raymond Chang Dr., Jason Overby ProfessorPublisher:McGraw-Hill EducationPrinciples of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
- Organic ChemistryChemistryISBN:9780078021558Author:Janice Gorzynski Smith Dr.Publisher:McGraw-Hill EducationChemistry: Principles and ReactionsChemistryISBN:9781305079373Author:William L. Masterton, Cecile N. HurleyPublisher:Cengage LearningElementary Principles of Chemical Processes, Bind...ChemistryISBN:9781118431221Author:Richard M. Felder, Ronald W. Rousseau, Lisa G. BullardPublisher:WILEY