Applied Statics and Strength of Materials (6th Edition)
6th Edition
ISBN: 9780133840544
Author: George F. Limbrunner, Craig D'Allaird, Leonard Spiegel
Publisher: PEARSON
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 18, Problem 18.43SP
Select the lightest extrastrong steel pipe section to support an axial compressive load of 90 kips. The column is pin-connected and has an unbraced length of 16 ft. Use the AISC column approach. Use Fy= 35 ksi.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Compute the design factor in the middle portion only of the rod AC if the steady vertical force on the boom is 2500 lb. The rod is rectangular, 1.50 in by 3.50 in, and is made from SAE 1144 cold-drawn steel. Include a mohr circle.
Select the lightest WT4 shape to be used as a 20 ft long tension member to resist the of dead load, D=40 k, live load, L=60 k, snow load, PS=25 k, and earthquake, E=110 k. The connection is two lines of bolts through the flange with three 3/4-in ∅ bolts in each line spaced at 3 in on center. Use A992 Grade 50 steel. Neglect block shear.
The column AB is connected to the frame through pin-joints as shown in Figure 1.
There exists a lateral support in the column at C only in the weak y-direction. Check if
a 200UB18.2 section of Grade 300 steel has adequate strength to be used as column
AB. If not, select an alternative UB section that has adequate strength.
Dead load, G = 40kN/m; Live load, Q = 20kN/m
2.8m
2.8m
B
1.2G+1.5Q
6m
A
Figure 1
Chapter 18 Solutions
Applied Statics and Strength of Materials (6th Edition)
Ch. 18 - Calculate the Euler buckling load for an axially...Ch. 18 - Calculate the Euler buckling load for a...Ch. 18 - A pin-connected axially loaded compression member...Ch. 18 - Prob. 18.4PCh. 18 - Plot a curve showing the relationship of feversus...Ch. 18 - A W1222 structural steel wide-flange section is...Ch. 18 - Prob. 18.7PCh. 18 - Calculate the allowable axial compressive load for...Ch. 18 - A W20059 structural steel wide-flange section is...Ch. 18 - Use Euler’s formula and a factor of safety of 2.5...
Ch. 18 - For Problems 18.11 through 18.17, unless otherwise...Ch. 18 - For Problems 18.11 through 18.17, unless otherwise...Ch. 18 - For Problems 18.11 through 18.17, unless otherwise...Ch. 18 - For Problems 18.11 through 18.17, unless otherwise...Ch. 18 - For Problems 18.11 through 18.17, unless otherwise...Ch. 18 - For Problems 18.11 through 18.17, unless otherwise...Ch. 18 - Prob. 18.17PCh. 18 - For Problems 18.18 through 18.21, use the...Ch. 18 - For Problems 18.18 through 18.21, use the...Ch. 18 - For Problems 18.18 through 18.21, use the...Ch. 18 - For Problems 18.18 through 18.21, use the...Ch. 18 - For Problems 18.22 through 18.26, assume normal...Ch. 18 - For Problems 18.22 through 18.26, assume normal...Ch. 18 - For Problems 18.22 through 18.26 assume normal...Ch. 18 - For Problems 18.22 through 18.26, assume normal...Ch. 18 - For Problems 18.22 through 18.26, assume normal...Ch. 18 - For the following computer problems, any...Ch. 18 - For the following computer problems, any...Ch. 18 - Calculate the Euler buckling load for an axially...Ch. 18 - 18.32 Calculate the Euler buckling load for an...Ch. 18 - 18.33 A structural steel shape of ASTM A992 steel...Ch. 18 - Calculate the Euler buckling load for a...Ch. 18 - 18.35 Rework Problem 18.34 assuming that the...Ch. 18 - 18.36 A built-up steel column is made by welding a...Ch. 18 - A 2-in-diameter standard-weight steel pipe is used...Ch. 18 - A structural steel column is 30 ft long and must...Ch. 18 - 18.39 Compute the allowable axial compressive load...Ch. 18 - 18.40 Determine the allowable axial compressive...Ch. 18 - 18.41 Using the AISC column approach, compute the...Ch. 18 - Using the AISC column equations, select the...Ch. 18 - Select the lightest extrastrong steel pipe section...Ch. 18 - 18.44 Compute the required diameter of a steel...Ch. 18 - 18.45 A 19-mm-diameter steel rod is 350 mm in...Ch. 18 - 18.46 A pin-connected linkage bar is 16 in. long...Ch. 18 - Prob. 18.47SPCh. 18 - Prob. 18.48SPCh. 18 - Prob. 18.49SPCh. 18 - Prob. 18.50SPCh. 18 - Prob. 18.51SP
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Please do this question for me and I’ll upvote your answer if it is correctarrow_forwardNeed right complete solutionarrow_forwardCompute the internal diameter of the 10 m length hollow cast iron column. If the externaldiameter is two times the internal diameter and the safe compressive load on a hollowcast iron column with one end rigidly fixed and other end hinged is 60 kN. Use Euler’sformula with a factor of safety of 3 and E = 90 kN/mm2arrow_forward
- Write legibly, provide manual step by step solution, and diagram for below given problem. A column supports a compressive load of 360KN. Determine the outside diameter of column if inside diameter is 195mm and compressive stress of 90Mpa. (Ans. Do = 20.7.65mm)arrow_forward(a) Explain FIVE (5) factors that may influence the optimum column design under an axial compressive load. (b) A 3.6 m long pin-ended column is formed from an A-36 steel circular hollow section with an outer diameter of 75 mm. Determine the minimum thickness, t (to the nearest integer in mm) of the circular hollow section so that the column can safely support the load of 200 kN without buckling. If the outer diameter of the steel circular hollow section is reduced to 62 mm and the ends are pinned-fixed supported, analyse whether the column with the same applied load and the sectional thickness computed above will cause a buckling failure.arrow_forwardA circular bar is used as a column carrying a load of 8500 lb with pinned ends. The length of the bar is 50 in. Use SAE 4140 OQT1000 steel and design factor of 3.0. (E for steel = 30,000 ksi) Determine the required diameter of the column D = in (Must show calculations and attach the worksheets in the last question)arrow_forward
- To calculate the maximum axial loads for a column based on yielding and buckling about both axes, and allowing for factors of safety. The critical load P for buckling of a column depends on the vertical distance between supports and how the column is connected to those supports. The length L in the T'EI formula Per =- is the distance between points of zero moment. For a pin- L2 supported column, this is the full height of the column. For a column that is not pinned at both ends, the points of zero moment are not at the supports. The equation for the critical load can be modified to use an effective length Le = KL, where K depends on the support conditions. For a column fixed at both ends, K = 0.5. For a column fixed at one end and pinned at the other, K = 0.7 (Figure 1). The equation for the critical load then becomes ’EI Pa (KL)²arrow_forwardUuestion 1: Calculate the axial load of spiral column with respect to first and second peaks. Materials used are C25 and S420 for longitudinal bars of 8- 024 and for spirals. Use the design strength of concrete and steel. 2. A, fywk 0, = D (s) 4. Ao P. = D (s) fa = f+4.0-0, GAP fa 4. f ynk (A min p, = 0.45. , min p, = 0.12. ywk D=550 mm H=600 mm Spiral : 010/85 mm 200 mmarrow_forwardQuestion: 35 35 The one end of a hollow square bar whose side is (10 +) in with (1 +) in thickness is under 100. 100 a tensile stress 102,500 psi and the other end is connected with a U bracket using a double-pin system. Find the minimum diameter of pin is used according to shear strength. Take the factor of safety as 1.5 and oau = 243 ksi for pin material. Notes: - Never change the template and only write your own identity data. - Your N value is in the list below and is unique to you. - Take at least 3 digits after the decimal point. - Specify the units. - You can use Word Equation or paste your solution on the page(s). - If you are preparing the application homework with your handwriting, be sure to take the photo with the paper in front view. Terms may not be selected for angled shots.arrow_forward
- Question 4 of 10 -/ 10 Current Attempt in Progress AWT205 x 30 structural steel section (see Appendix B for cross-sectional properties) is used for a 6.6 mcolumn. Assume pinned connections at each end of the column. Determine: (a) the slenderness ratio. (bi the Euler buckling load. Use E- 200 GPa for the steel. (c) the asdal stress in the columnwhen the Euler load is applied. Part 1 Use Appendix B to lookup the cross-sectional area, the area moment of inertia, and the radius of gyration for a WT205 x 30 structural steel section. Answer A x 10 mm mm x 10 mm mmarrow_forwardA structural support for a machine will be subjected to a static tensile load of 16.0 kN. It is planned to fabricate the support from a square rod made from SAE 1020 hot-rolled steel. Specify suitable dimensions for the cross section of the rod.arrow_forwardPlease give the given, required, and the solution. Draw the free body diagram and label properly.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Mechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage Learning
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning
Everything About COMBINED LOADING in 10 Minutes! Mechanics of Materials; Author: Less Boring Lectures;https://www.youtube.com/watch?v=N-PlI900hSg;License: Standard youtube license