Question
Chapter 12, Problem 21E
(a)
To determine
The power factor of the source for the given condition.
(b)
To determine
The total power supplied by the source for the given condition.
(c)
To determine
The power factor and the total power delivered by the source for the given condition.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Three Impedances each of (12 -j18)N are connected in mesh across a three-phase 420V ac supply.
Determine the phase current, line current, active power, reactive power drawn from the supply.
phase current (Ip)
Line current
real power
reactive power
A balanced delta-connected load is supplied by a 60 Hz
3-phase source with a line voltage of 240 V. Each load
phase draws 6kW at a lagging power factor of 0.8.
Calculate:
a. The load impedance per phase
b. The line current
c. The value of the capacitance needed to be
connected in parallel with each load to minimize
the current from the source (PF=1)
Given the circuit fed by 3 phases 380V phase to phase voltage, with 50HZ.
a) Draw the power triangle of each of the loads (P, Q and S).
b) Find the total equivalent (P, Q and S).
c) Find the Value of Capacitor bank in order to have a unity power factor.
d) Find the complex power supplied by the source after adding the capacitor bank.
e) Explain why higher power factor is better for the installation
3 phases
380 v
50 Hz
Load 1
Load 1
15 KVA
25 KVA
0.75 Lagging
0.85 Lagging
Chapter 12 Solutions
Loose Leaf for Engineering Circuit Analysis Format: Loose-leaf
Ch. 12.1 - Let and . Find (a) Vad; (b) Vbc; (c) Vcd.Ch. 12.2 - Prob. 2PCh. 12.2 - Modify Fig. 12.9 by adding a 1.5 resistance to...Ch. 12.3 - A balanced three-phase three-wire system has a...Ch. 12.3 - A balanced three-phase three-wire system has a...Ch. 12.3 - Three balanced Y-connected loads are installed on...Ch. 12.4 - Each phase of a balanced three-phase -connected...Ch. 12.4 - Prob. 8PCh. 12.5 - Determine the wattmeter reading in Fig. 12.24,...Ch. 12.5 - Prob. 10P
Ch. 12 - Prob. 1ECh. 12 - Prob. 2ECh. 12 - Prob. 3ECh. 12 - Describe what is meant by a polyphase source,...Ch. 12 - Prob. 5ECh. 12 - Prob. 6ECh. 12 - Prob. 7ECh. 12 - Prob. 8ECh. 12 - Prob. 9ECh. 12 - Prob. 10ECh. 12 - The single-phase three-wire system of Fig. 12.31...Ch. 12 - Prob. 12ECh. 12 - Referring to the balanced load represented in Fig....Ch. 12 - Prob. 14ECh. 12 - Prob. 15ECh. 12 - Consider a simple positive phase sequence,...Ch. 12 - Assume the system shown in Fig. 12.34 is balanced,...Ch. 12 - Repeat Exercise 17 with Rw = 10 , and verify your...Ch. 12 - Prob. 19ECh. 12 - Prob. 20ECh. 12 - Prob. 21ECh. 12 - Prob. 22ECh. 12 - A three-phase system is constructed from a...Ch. 12 - Prob. 24ECh. 12 - Each load in the circuit of Fig. 12.34 is composed...Ch. 12 - Prob. 26ECh. 12 - Prob. 27ECh. 12 - A three-phase load is to be powered by a...Ch. 12 - For the two situations described in Exercise 28,...Ch. 12 - Prob. 30ECh. 12 - Prob. 31ECh. 12 - Prob. 32ECh. 12 - Repeat Exercise 32 if Rw = 1 . Verify your...Ch. 12 - Prob. 34ECh. 12 - Prob. 35ECh. 12 - Prob. 36ECh. 12 - A wattmeter is connected into the circuit of Fig....Ch. 12 - Find the reading of the wattmeter connected in the...Ch. 12 - (a) Find both wattmeter readings in Fig. 12.39 if...Ch. 12 - Circuit values for Fig. 12.40 are , , , , . Find...Ch. 12 - Prob. 41ECh. 12 - Prob. 42ECh. 12 - (a) Is the load represented in Fig. 12.41...Ch. 12 - Prob. 44E
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- HW9 12.31 A balanced delta-connected load is supplied by a 60-Hz three-phase source with a line voltage of 240 V. Each load phase draws 6 kW at a lagging power factor of 0.8. Find: (a) the load impedance per phase (b) the line current (c) the value of capacitance needed to be connected in parallel with each load phase to minimize the current from the sourcearrow_forward12.25 In the circuit of Fig. 12.54, if Vab = 220/10°, Vc = 220/-110°, Vca = 220/130° V, find the line ps currents. %3D %3D 3+j20 I a Vab 10 - j8 2 3+j20 I 10 – j8 2 10 - j8 2 3+j20 Iarrow_forwardanswer last 2 pleasearrow_forward
- Question 1: Find the line currents Ia, Ib, and Ic in the three-phase network of Fig. 12.53 below. Take Z₁ = 12 - j15 0, Zy = 4 + j6 , and Z₁ = 2 . Z₁ Ia 440/120° V 440/-120° V 440/0° V Z₁ Z₁ Ic B 20 Zy A ZA Zy N Zy ZA Carrow_forwardPlease only expert should solve this question onlyarrow_forward12 3 loads, each of resistance of 40 Ω and inductance of 160.2 mH are connected in delta with a 3-phase supply. Frequency is 50 Hz. Find the inductive reactance (XL) of the each phase. a. 40 Ω b. 50.33 Ω c. 25.16 Ω d. 12.58 Ωarrow_forward
- Three Impedances each of (8 - j24)2 are connected in mesh across a three-phase 420V ac supply. Determine the phase current, line current, active power, reactive power drawn from supply. Also draw the Phasor diagram for the mesh connection and marks the Line current ,phase current line voltage and phase angle between phase current and pahse voltage. phase current (Ip) Line current real power reactive powerarrow_forwardA 200 V single phase circuit has an apparent power of 5 KVA and reactive power of 4 KVAr. Then find (i) power factor (ii) impedance (iii) resistance (iv) reactance.arrow_forwardYou have a three-phase Y-connected load where each branch consists of a 3 [w] resistor and a j4 [W] inductor connected in series. If the line-to-neutral voltage is 500 [V, the approximate total reactive power supplied to the three- phase load is:arrow_forward
- Find the line currents in the unbalanced three-phase circuit of Fig. 12.26 and the real power absorbed by the load. 220-120° rms V Figure 12.26 220/0° rms V 220/120⁰ rms V b -j5Q B A www j1092 1092 Carrow_forwardThree loads are connected in parallel across a 12.47 kV, 60Hz three-phase supply. Load 1: Inductive load, 60 kW at 0.75 power factor. Load 2: Capacitive load, 300 kW at 0.8 power factor. Load 3: Resistive load of 60 kW. a) Find the total complex power, power factor, and the supply current. b) A Y-connected capacitor bank is connected in parallel with the loads. Find the total kvar and the capacitance per phase to improve the overall power factor to 0.95 lagging. c) What is the new line current for the 0.95 lagging pf condition?arrow_forwardTwo loads are connected in parallel across a line to line voltage 13 kV three-phase supply (Y-connected). Load 1: Inductive load, 60 kW and 660 KVAR. Load 2: Capacitive load, 240 kW at 0.8 power factor. a) If a Y-connected capacitor bank is connected in parallel with the loads. Find the the capacitance per-phase in uF to improve the overall power factor to 0.8 lagging. b) Compare the line current before and after power factor correctionarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
What is the Difference Between Single Phase and Three Phase???; Author: Electrician U;https://www.youtube.com/watch?v=FEydcr4wJw0;License: Standard Youtube License