Textbook Question
Chapter 12, Problem 13E
Referring to the balanced load represented in Fig. 12.33, if it is connected to a three-wire balanced source operating at 50 Hz such that VAN = 115 V, (a) determine the power factor of the load if the capacitor is omitted; (b) determine the value of capacitance C that will achieve a unity power factor for the total load.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Problem 2
For the system shown in Figure 12.5:
a) Find Is.
b) Find the average power delivered to each element.
c) Find the reactive power associated with each element.
d) Find PT, QT, and ST.
e) Find the power factor seen by the
source E.
R₁
ww
392
+
E = 50 V/60°
R3
ww
492
R₂
12 Ω Χ
16Ω
Xc
802
Figure 12.5
plz find the problem in less than 30 min plz.
Help
Chapter 12 Solutions
ENGINEERING CIRCUIT...(LL)>CUSTOM PKG.<
Ch. 12.1 - Let and . Find (a) Vad; (b) Vbc; (c) Vcd.Ch. 12.2 - Prob. 2PCh. 12.2 - Modify Fig. 12.9 by adding a 1.5 resistance to...Ch. 12.3 - A balanced three-phase three-wire system has a...Ch. 12.3 - A balanced three-phase three-wire system has a...Ch. 12.3 - Three balanced Y-connected loads are installed on...Ch. 12.4 - Each phase of a balanced three-phase -connected...Ch. 12.4 - Prob. 8PCh. 12.5 - Determine the wattmeter reading in Fig. 12.24,...Ch. 12.5 - Prob. 10P
Ch. 12 - Prob. 1ECh. 12 - Prob. 2ECh. 12 - Prob. 3ECh. 12 - Describe what is meant by a polyphase source,...Ch. 12 - Prob. 5ECh. 12 - Prob. 6ECh. 12 - Prob. 7ECh. 12 - Prob. 8ECh. 12 - Prob. 9ECh. 12 - Prob. 10ECh. 12 - The single-phase three-wire system of Fig. 12.31...Ch. 12 - Prob. 12ECh. 12 - Referring to the balanced load represented in Fig....Ch. 12 - Prob. 14ECh. 12 - Prob. 15ECh. 12 - Consider a simple positive phase sequence,...Ch. 12 - Assume the system shown in Fig. 12.34 is balanced,...Ch. 12 - Repeat Exercise 17 with Rw = 10 , and verify your...Ch. 12 - Prob. 19ECh. 12 - Prob. 20ECh. 12 - Prob. 21ECh. 12 - Prob. 22ECh. 12 - A three-phase system is constructed from a...Ch. 12 - Prob. 24ECh. 12 - Each load in the circuit of Fig. 12.34 is composed...Ch. 12 - Prob. 26ECh. 12 - Prob. 27ECh. 12 - A three-phase load is to be powered by a...Ch. 12 - For the two situations described in Exercise 28,...Ch. 12 - Prob. 30ECh. 12 - Prob. 31ECh. 12 - Prob. 32ECh. 12 - Repeat Exercise 32 if Rw = 1 . Verify your...Ch. 12 - Prob. 34ECh. 12 - Prob. 35ECh. 12 - Prob. 36ECh. 12 - A wattmeter is connected into the circuit of Fig....Ch. 12 - Find the reading of the wattmeter connected in the...Ch. 12 - (a) Find both wattmeter readings in Fig. 12.39 if...Ch. 12 - Circuit values for Fig. 12.40 are , , , , . Find...Ch. 12 - Prob. 41ECh. 12 - Prob. 42ECh. 12 - (a) Is the load represented in Fig. 12.41...Ch. 12 - Prob. 44E
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Problem 4 Two loads are connected in parallel across a 1000-V rms, 60-Hz source. One load absorbs 450 kW at 0.6 power factor lagging, and the second load absorbs 500 kW and 400 KVAR. Determine the value of the capacitor that should be added in parallel with the two loads to improve the overall power factor to 0.9 lagging.arrow_forwardA threephase, balanced load is star (wye) connected and consumes 180 kW from the grid (400Vrms@50Hz). A capacitor bank (also balanced) of 65 kVAr is connected in parallel. As a result the total power factor equals 0.90. a) Determine the power factor of the load (so without capacitor bank. b) The capacitor bank is delta connected. Determine the capacitance of the capacitors.arrow_forwardA 230 V, 50 Hz power source is connected to the some loads, where: • Load-1: R = 4.5 Q and in series connection with L = 8 mH. • Load-2: 10 kVA of power factor 0.6 lagging. • Load-3: 5 KVAR of power factor 0.5 lagging. (i) Determine the active power and reactive power of the Load-1. (ii) Determine the total current delivers by the supply and the total power factor. (iii) Calculate the required capacitor in order to increase the power factor to unity.arrow_forward
- Example: A balanced positive-sequence wye-connected 60 Hz three-phase source has line-to- line voltages of V,=1000 V. This source is connected to a balanced wye-connected load. Each phase of the load consists of a 0.2 H inductance in series with a 100 0 resistance. Find the line-to-neutral voltages, the line currents, the power, and the reactive power delivered to the load. Assume that the phase of Van is zero.arrow_forwardPart g,harrow_forward1) Determine the total current supplied by the source and the current in each branch. 2) Sketch a fully labelled phasor diagram showing all voltage and currents in the circuit. 3) Determine the active power delivered by the source voltage. 4) Determine the reactive power. 5) Sketch the power triangle. 6) Comment on the significance of the power factor and briefly state how it can be improved.arrow_forward
- A 3-phase identical load is connected in delta and consist of a resistance of 160 n and an inductance of 0.382 H in each phase. This load is supplied by 3-phase system of 5 kV, 50 Hz Find: a) The line current b) The active power c) The reactive power d) Tne apparent powerarrow_forwardA balanced positive-sequence wye-connected 60-Hz three-phase source has line-to-line voltages of VL = 440 V rms. This source is connected to a balanced wye-connected load. Each phase of the load consists of a 0.5-H inductance in series with a 30-Ω resistance. Assume that the phase of VanVan is zero. FIND Ia,Ib,Ic, Find the power delivered to the load And Find the reactive power delivered to the load.arrow_forwardA single-phase, 60-Hz supply is connected to a load consisting of a 100 Ω resistor in parallel with a 50-µF capacitor. Find the source power factor. (Make sure to indicate leading or lagging PF)arrow_forward
- Lrms/wgk = 202-30°A Vms/wgk 22020°V 50 Hzarrow_forwardPlease answer quickly "In series-connected ac circuit, the total voltage across the circuit is always equal to the sum of the magnitude (only) of the individual voltage across each element." True False The power factor is equal to cosine of the phase difference. True False A leading power factor means that the circuit is predominantly capacitive in nature. True False "Since most loads are resistive in nature (e.g. motors), improvement of power factor is done by connecting capacitor banks or a synchronous condenser " True Falsearrow_forwardTwo loads are connected in parallel to a source of emf whose voltage is (110 + j63.5). if the branch currents are ?1= (8 – j8) & ?2= (7.5 + j10). Calculate the following items below. a. Total current b. Equivalent impedance c. Total power d. Reactive powerarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
Capacitors Explained - The basics how capacitors work working principle; Author: The Engineering Mindset;https://www.youtube.com/watch?v=X4EUwTwZ110;License: Standard YouTube License, CC-BY