Refrigerant-134a enters the condenser of a residential heat pump at 800 kPa and 50°C at a rate of 0.022 kg/s and leaves at 750 kPa subcooled by 3°C. The refrigerant enters the compressor at 200 kPa superheated by 4°C. Determine (a) the isentropic efficiency of the compressor, (b) the rate of heat supplied to the heated room, and (c) the COP of the heat pump. Also, determine (d) the COP and the rate of heat supplied to the heated room if this heat pump operated on the ideal vapor-compression cycle between the pressure limits of 200 and 800 kPa.
FIGURE P11–42
(a)
The isentropic efficiency of the compressor.
Answer to Problem 42P
The isentropic efficiency of the compressor is
Explanation of Solution
Show the T-s diagram for process as in Figure (1).
From Figure (1), write the specific enthalpy at state 3 is equal to state 4 due to throttling process.
Here, specific enthalpy at state 3 and 4 is
Express isentropic efficiency of the compressor.
Here, specific enthalpy at state 1, 2 and 2s is
Express the temperature at state 3.
Here, saturated temperature at pressure of
Express the temperature at state 1.
Here, saturated temperature at pressure of
Express quality at state 2s.
Here, specific entropy at saturated liquid and evaporation and
Express specific enthalpy at state 2s.
Here, specific enthalpy at saturated liquid and evaporation and
Conclusion:
Perform unit conversion of pressure at state 2 from
Refer Table A-13, “superheated refrigerant 134a”, and write the specific enthalpy at state 2 corresponding to pressure at state 2 of
Refer Table A-12, “saturated refrigerant-134a-pressure table” and write saturated temperature at pressure of
Substitute
Refer Table A-12, “saturated refrigerant-134a-pressure table” and write specific enthalpy at state 3 corresponding to pressure at state 3 of
Write the formula of interpolation method of two variables.
Here, the variables denote by x and y is temperature at state 3 and specific enthalpy at state 3 respectively.
Show the specific enthalpy at state 3 corresponding to temperature as in Table (1).
Temperature at state 3 |
Specific enthalpy at state 3 |
26.69 | 88.82 |
26.06 | |
29.06 | 92.22 |
Substitute
Since the specific enthalpy at state 3 is equal to state 4 due to throttling process.
Refer Table A-12, “saturated refrigerant-134a-pressure table” and write saturated temperature at pressure of
Substitute
Refer Table A-12, “saturated refrigerant-134a-pressure table” and write specific enthalpy and entropy at state 1 corresponding to pressure at state 1 of
Here, specific entropy at state 1 is
The specific entropy at state 1 is equal to specific entropy at state 1.
Here, specific entropy at state 2 is
Refer Table A-12, “saturated refrigerant-134a-pressure table” and write the properties corresponding to pressure at state 2 of
Substitute
Substitute
Substitute
Hence, the isentropic efficiency of the compressor is
(b)
The rate of heat supplied to the heated room.
Answer to Problem 42P
The rate of heat supplied to the heated room is
Explanation of Solution
Express the rate of heat supplied to the heated room.
Here, mass flow rate is
Conclusion:
Substitute
Hence, the rate of heat supplied to the heated room is
(c)
The COP of the heat pump.
Answer to Problem 42P
The COP of the heat pump is
Explanation of Solution
Express the rate of work input.
Express coefficient of performance of heat pump.
Conclusion:
Substitute
Substitute
Hence, the COP of the heat pump is
(d)
The COP and the rate of heat supplied to the heated room.
Answer to Problem 42P
The COP and the rate of heat supplied to the heated room is
Explanation of Solution
Show the T-s diagram for ideal vapor compression cycle as in Figure (2).
From Figure (2), write the specific enthalpy at state 3 is equal to state 4 due to throttling process.
Express the coefficient of performance.
Express the rate of heat supplied to the heated room.
Conclusion:
Refer Table A-12, “saturated refrigerant-134a-pressure table”, and write the properties corresponding to initial pressure of
Here, specific entropy at state 1 is
Refer Table A-13, “superheated refrigerant 134a”, and write the specific enthalpy at state 2 corresponding to pressure at state 2 of
Show the specific enthalpy at state 2 corresponding to specific entropy as in Table (2).
Specific entropy at state 2 |
Specific enthalpy at state 2 |
0.9185 | 267.34 |
0.9379 | |
0.9481 | 276.46 |
Use Excels and substitute the values from Table (2) in Equation (VI) to get,
Refer Table A-12, “saturated refrigerant-134a-pressure table”, and write the specific enthalpy at state 3 corresponding to pressure at state 3
Here, specific enthalpy at saturated liquid is
Since the specific enthalpy at state 3 is equal to state 4 due to throttling process.
Substitute
Substitute
Hence, the COP and the rate of heat supplied to the heated room is
Want to see more full solutions like this?
Chapter 11 Solutions
THERMODYNAMICS LLF W/ CONNECT ACCESS
- 3. Refrigerant-134a enters the condenser of a residential heat pump at 800 kPa and 35°C at a rate of 0.018 kg/s and leaves at 800 kPa as a saturated liquid. If the compressor consumes 1.2 kW of power, determine: (a) the COP of the heat pump and (b) the rate of heat absorption from the outside air. OH 800 kPa 800 kPa 35°C x=0 Condenser Evaporator Q Expansion valve Compressorarrow_forwardRefrigerant- 134a enters the condenser of a residential heat pump at 200 kPa and 35°C at a rate of 0.161 kg/s and leaves at 200 kPa as saturated liquid. If the compressor consumes 2.5 kW of power, determine (a) the COP of the heat pump and (b) the rate of heat absorption from outside air COP = 10.657 & QL = 10 998 kW COP = 6346 & QL = 15.758 KW COP = 12.658 & QL = 12.667 kW COP = 15.773 & QL = 36.931 kWarrow_forwardRefrigerant-134a enters the compressor of a refrigerator at 0.14MPa and -10°C at a rate of 0.05 kg/s and leaves at 0.8 MPa and 50°C. The refrigerant is cooled in the condenser to 26°C and 0.72 MPa and is throttled to 0.15 MPa. Determine (a) the rate of heat removal from the refrigerated space and the power input to the compressor, (b) the isentropic efficiency of the compressor, and (c) the coefficient of performance of the refrigerator. Answers: (a) 7.93 kW, 2.02 kW, (b) 0.939, (c) 3.93arrow_forward
- A heat pump uses R-134a as the refrigerant. The refrigerant enters the adiabatic compressor as saturated vapor at 120 kPa and exits it (the compressor) at 800 kPa and 50°C. The refrigerant exits the condenser as saturated liquid at 800 kPa. Then, the refrigerant flows through an adiabatic expansion valve, reducing the pressure back to the evaporator pressure of 120 kPa. The compressor power is 1.25 kW. a) Calculate the mass flow rate of the refrigerant (R-134a) in kg/s or g/s. b) Calculate the heat power delivered from the condenser in kW. c) Calculate the coefficient of performance (COP) of the heat pump, COP_HP.d) Calculate the refrigerant’s vapor quality entering the evaporator.arrow_forwardA heat pump using refrigerant-134a heats a house by using underground water at 8°C as the heat source. The house is losing heat at a rate of 60,000 kJ/h. The refrigerant enters the compressor at 280 kPa and 0°C, and it leaves at 1 MPa and 60°C. The refrigerant exits the condenser at 30°C. Investigate the effect of varying the compressor isentropic efficiency over the range [60 to 100 percent]. Plot the power input to the compressor and the electric power saved by using a heat pump rather than electric resistance heating as functions of compressor efficiency and discuss the results.arrow_forwardRefrigerant-134a enters the condenser of a residential heat pump at 200 kPa and 35°C at a rate of 0.161 kg/s and leaves at 200 kPa as saturated liquid. If the compressor consumes 2.5 kW of power, determine (a) the COP of the heat pump and (b) the rate of heat absorption from outside air COP = 10 657 & QL = 10 998 kW COP = 6 346 & QL = 15 758 kW COP = 12 658 & QL = 12 667 kW COP= 15 773 & QL = 36.931 kWarrow_forward
- can any one help ?arrow_forwardRefrigerant-134a enters the condenser of a residential heat pump at 1400 kPa and 65°C at a rate of 0.062 kgis and leaves at 1400 kPa as saturated liquid. If the compressor consumes 1.6 KW of power, determine (a) the COP of the heat pump and (b) the rate of heat absorption from outside air COP 3.651V& QL 4 465 kW COP 6.356 & QL 8.570 kW COP = 5432 & QL 9.653 kW COP 1.346& QL= 2.784 kWarrow_forward: Refrigerant 134a enters a compressor of a vapour compression of a refrigeration cycle at 120Kpa as a saturated vapour and leaves at 900 Kpa and 75oc. The refrigerant leaves the condenser as a saturated liquid. The rate of cooling provided by the system is 18000 Btu/hr. Determine (1) Mass flow rate of R134a (2) The Cop of the cycle (3) Also determine the Cop of the cycle if the expansion valve is replaced by an isentropic turbine. Do you recommend such a replacement for the refrigeration system? (4) Determine the Cop if the evaporator pressure is 160Kpa and otheer values remains the same. (5) Determine the Cop if the condenser pressure is 800 Kpa and other values remain the same.arrow_forward
- A heat pump using refrigerant-134a heats a house by using underground water at 8°C as the heat source. The house is losing heat at a rate of 60,000 kJ/h. The refrigerant enters the compressor at 280 kPa and 0°C, and it leaves at 1 MPa and 60°C. The refrigerant exits the condenser at 30°C. Determine (a) the power input to the heat pump, (b) the rate of heat absorption from the water, and (c) the increase in electric power input if an electric resistance heater is used instead of a heat pump. Answers: (a) 3.55 kW (b) 13.12 kW (c) 13.12 kWarrow_forwardA heat pump using refrigerant-134a heats a house by using underground water at 8°C as the heat source. The house is losing heat at a rate of 60,000 kJ/h. The refrigerant enters the compressor at 280 kPa and 0°C, and it leaves at 1 MPa and 60°C. The refrigerant exits the condenser at 30°C. Determine (a) the power input to the heat pump, (b) the rate of heat absorption from the water, and (c) the increase in electric power input if an electric resistance heater is used instead of a heat pump. Using appropriate software such as EXCEL, investigate the effect of varying the compressor isentropic efficiency over the range 60 to 100 percent by plotting the power input to the compressor and the electric power saved by using a heat pump rather than electric resistance heating as functions of compressor efficiency.arrow_forwardA refrigerator uses refrigerant-134a as the working fluid and operates on an ideal vapourcompression refrigeration cycle between 0.12 MPa and 0.7 MPa. The mass flow rate of therefrigerant is 0.05 kg/s. Show the cycle on a T-s diagram with respect to saturation lines.Determine;(a) The rate of heat removal from the refrigerated space and the power input to thecompressor,(b) The rate of heat rejection to the environment, and(c) The coefficient of performance.arrow_forward
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY