Question
Chapter 11, Problem 11.9QAP
Interpretation Introduction
Interpretation:
Differentiate between isobaric interference and polyatomic ion interference in ICPMS.
Concept introduction:
ICPMS stands for inductively coupled plasma mass spectrography. This is an important type of
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
outline the general procedure for determining a substance spectrophotometrically
Explain why an internal standard is required during sample preparation in quantitative analysis when using atomic spectroscopy?
A Raman spectrum of undoped GaAs at room temperature is performed with a 514.5 nm laser. The spectrum of scattered light exhibits peaks at wavelengths of 507.1 nm and 591.6 nm due to interaction of the incident light with LO phonons. Calculate the LO phonon frequency and the ratio of the intensity of scattered light at 507.1 nm to that at 591.6 nm.
Chapter 11 Solutions
Principles of Instrumental Analysis
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Similar questions
- Fluorometry is more selective and more sensitive than absorption spectrometry.Tell what is meant by selectivity and sensitivity.arrow_forwardInductively coupled plasma-optical emission spectroscopy (ICP-OES) is a quantitative method for determining trace elements in liquid samples. ICP-OES and other methods of spectrochemical analysis are typically subject to errors due to the present of interferences. It had been reported that ICP-OES is significantly affected by spectral interference, but relatively less affected by the chemical interferences. (i) Explain why ICP-OES is significantly affected by spectral interference but less affected by chemical interferences.arrow_forwardi) Find the differences between the AES and XPS in terms of principle and information obtained from the spectra. ii) Why AFM is mostly utilized microscopic method for the determination of the thickness of the film?arrow_forward
- Flame Atomic Absorption Spectroscopy (FAAS) method is selected due to its wide applicability for metal ion analysis in drinking water samples. Provide appropriate discussion to determine the concentration of selected heavy metals (Cu and Cr) in the unknown tap water sample.arrow_forward3arrow_forwardWhat are the interferences in AAS technique? Give examples and corrective measuresarrow_forward
- 3. Explain the main differences between flame atomic absorption spectrophotometry and UV-VIS molecular absorption spectrophotometry in terms of: (a) (b) energy levels and transitions; main instrumental features.arrow_forwardSuppose a student is preparing a set of standard solutions for use in a spectrophotometric study. If percent transmittance, %T, were measured in the standard solutions before the color had a chance to fully develop, the measured value would be compared with solutions that have allowed the color to fully develop.arrow_forward(a) What is the main difference between a UV-Vis spectrophotometer and a spectrofluorometer? (b) What is the main advantage of using a spectrofluorometer in quantitative analysis?arrow_forward
- 1. State the difference between transmittance, absorbance, molar absorptivity, and fluorescence. Which one(s) is proportional to analyte concentration?arrow_forwardAlexa Fluor 568 is a fluorescent dye that in aqueous solution displays a maximum absorbance at 576 nm, a quantum yield of 0.69, a lifetime of 3.60 ns and a Stokes shift of 24 nm. (i) Show a schematic of a typical fluorimeter and its main components. Briefly explain the role of each component. (ii) Explain what is the "Stokes shift" and what physical processes underpin the observation of such shifts; use diagrams and/or equations as appropriate in your explanation. (iii) Calculate the radiative decay constant of Alexa Fluor 568.arrow_forward6 Why standard solutions are used in Atomic absorption Spectroscopy (AAS) whereas UV-Vis molecular absorbance only extinction coefficient is necessary?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage LearningChemistry for Engineering StudentsChemistryISBN:9781285199023Author:Lawrence S. Brown, Tom HolmePublisher:Cengage Learning
- Principles of Modern ChemistryChemistryISBN:9781305079113Author:David W. Oxtoby, H. Pat Gillis, Laurie J. ButlerPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
Chemistry for Engineering Students
Chemistry
ISBN:9781285199023
Author:Lawrence S. Brown, Tom Holme
Publisher:Cengage Learning
Principles of Modern Chemistry
Chemistry
ISBN:9781305079113
Author:David W. Oxtoby, H. Pat Gillis, Laurie J. Butler
Publisher:Cengage Learning