Question
Chapter 11, Problem 11.2QAP
Interpretation Introduction
Interpretation:
A linear TOF mass spectrometer needs to be compared with an orthogonal TOF instrument. The advantages and limitations of the two geometries needs to be determined.
Concept introduction:
The measurement of time which is taken by a wave, object, or particle to travel the given distance with the help of a medium is called time-of-flight. Time-of-flight mass spectrometry is a technique, which helps in determining the ratio of mass-to-charge of an ion with the help of time-of-flight measurements.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Q6. (a) Describe the differences between a linear TOF mass spectrometer and an orthogonal
TOF instrument? What are the advantages and limitations of these two geometries? *
(b) What function does the ICP torch have in ICPMS?
(c) Why has ICPMS become an important and widely used analytical method?
What is the purpose of a matrix modifier in atomic spectroscopy?
What are the differences between a mass spectrometer and a IR spectrometer?
Chapter 11 Solutions
Principles of Instrumental Analysis
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Similar questions
- Why is 133C-133C spin-spin splitting not observed in ordinary organic compounds?arrow_forwardDescribe the units of IR in relation to frequency and energy and describe the functions of an FT-IR spectrometer.arrow_forwardA student calibrated the mini-spectrophotometer with a blank solution, and then went to check their solution. They got a fingerprint on the cuvette while filling it. Because of this, the expected reading for the absorbance would be too high which would cause the calculated value of K, to be too higharrow_forward
- Answer the questions regarding a single Fourier transform infrared spectroscopy (FTIR) experiment. The interferogram was sampled at a retardation interval (8) of 0.0001297 cm. What wavenumber range is possible with a sample retardation interval (8) of 0.0001297 cm? Aỹ = cm- For a spectrum acquired in 8-bit space (256 data points sampled) for ô = -A to d = +A , determine the value of maximum retardation (A) and the resolution (R). A = cm R = cm-1 What is the interferometer mirror velocity if each data point required 267 us (tintt) to obtain? Vint = cm/sarrow_forward5. Show that 'H nuclei with large chemical shifts relative to TMS have small shielding constants.arrow_forwardImagine you are trying to analyze Zn2* in a multivitamin. 7. Discuss with your group: what are other ions which may be in a multivitamin that could make the quantitation of Zn2+ difficult? analyte signal = F (standard signal S samp = KĄCA Sspike = kA (CAVotVad Vo V std + Cstd [analyte] [standard] Vo+V stdarrow_forward
- Chemistry Questionarrow_forwardIn a mass spectrometer, two beams of singly ionized isotopes of uranium 23592U and 23892U are injected with velocity 1.4*105m/s into a magnetic field of strength 0.7 T normally. Compute the distance d between the two trace lines of the isotopes after they complete one semi-circle. (Given: masses of the isotopes are m235 = 3.9*10-25 kg and m238 = 3.95*10-25) a) 1.26 cm b) 0.63 cm c) 0.32 cm d) none of these.arrow_forward4. When plotting a standard curve in absorption spectrophotometry, one uses Abs values instead of %T values. Explain why you need to use Abs values instead of %T values when constructing a standard curve (or a linear Beer's law Plot)arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage LearningPrinciples of Modern ChemistryChemistryISBN:9781305079113Author:David W. Oxtoby, H. Pat Gillis, Laurie J. ButlerPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
Principles of Modern Chemistry
Chemistry
ISBN:9781305079113
Author:David W. Oxtoby, H. Pat Gillis, Laurie J. Butler
Publisher:Cengage Learning