Principles of Instrumental Analysis
7th Edition
ISBN: 9781305577213
Author: Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 11, Problem 11.8QAP
Interpretation Introduction
Interpretation:
Description of distance of flight mass spectrometer and the difference between flight mass spectrometer and TOF instrument.
Concept introduction:
Distance of flight mass spectrometer or DOFMS helps in separating the ions which are of different mass-to-charge (m/z) by the distance which is traveled in a given point of time after acceleration.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Quantitative Analysis by External Standard Method
Calcium in a juice sample is determined by atomic absorption spectrophotometry.
A stock solution of calcium is prepared by dissolving 1.834 g of CaCl, 2H20 in water and diluting to 1000.0 mL.
A substock calcium solution was prepared by transferring 10.00 mL of the stock to a 100.00 mL volumetric
flask and diluting to the mark. Three standard solutions of calcium were prepared by transferring 2.500 mL.
5.00 mL and 10.00 mL of substock to 50.00 mL volumetric flasks and diluting to the mark.
The sample is prepared by transferring 1.000 mL of fruit juice from the original bottle to a 25.00 mL flask and
diluting to the mark.
Strontium chloride is added to all solutions before dilution to avoid phosphate interference. Instrumental
response of the standards is measured against the blank, and the following readings are recorded: 9.10, 18.6
and 37.0. The sampie reading is 28.1.
Using the multipoint method, find the concentration of calcium in…
If a TOF mass spectrometer needs to scan an m/z of 600, what is the speed of this ion if it is accelerated through 4000 volts? How long will this ion (at the speed calculated) take to drift 2.00 m through the spectrometer? How many mass spectra can be taken each second if a new cycle begins each time this ion reaches the detector?
Chemistry
Common Isotopes and Mass spectrum of element Mo are given below
Most common isotopes: Mo-98; Mo-96 Mo-95; Mo-92; Mo-97 ; Mo-100; Mo-94
Calculate the average atomic mass of Mo
How the MS determined the relative intensity (Scale of 100) and Isotope abundance (%)?
Why absolute intensity was not used?
Can detector sensitivity, ICPMS temperature influence the relative intensity? Explain
Chapter 11 Solutions
Principles of Instrumental Analysis
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Similar questions
- I need the chart filled out with an explanation please :))arrow_forwardshow-all-working-explaining-detailly-each-step Answer should be typewritten using a computer keyboard.arrow_forwardThe validation process comprises four main steps that are : hardware validation, software validation, method validation and system suitability. To evaluate a spectrophotometer’s accuracy by measuring absorbance, a solution of 60.06 mg/L K2Cr2O7 in 0.0050M H2SO4 was carefully prepared together with a 0.0050 M H2SO4 as a reagent blank. If the spectrometer’s signal is properly calibrated, it has been reported that this solution should provide an absorbance of 0.640 +- 0.010 at wavelength 350 nm. Which one of the validations mentioned above had been involved in this process? Explain your choicearrow_forward
- In the process of performing a spectrophotometric determination of Fe, an analyst prepares a calibration curve using a single-beam spectrometer, such as a Spec-20. After preparing the calibration curve, the analyst drops the cuvette used for the method blank and the standards. The analyst acquires a new cuvette, measures the absorbance of the sample, and determines the %w/w Fe in the sample. Will the change in cuvette lead to a determinate error in the analysis? Explain.arrow_forwardIf the standard addition intercept is the major source of uncertainty, find the uncertainty in the concentration of Sr in tooth enamel in parts per million. Find the 95% confidence interval for Sr in tooth enamel.arrow_forwardWhen LC is coupled with mass spectrometry (MS), what are the advantages (compared to LC only) in terms of analyte identification and quantitation in the sample?arrow_forward
- For an ASTM grain size of 9, approximately how many grains would there be per square inch (a) at a magnification of 100? (b) without any magnification?arrow_forwardThe maximum number of spectra that can be recorded per second by ToF-MS is limited by the time taken by the slowest ions to go from the source to the detector. If the slowest ion took 45.6 microsecond to travel, at what frequency could you record spectra if a new extraction cycle were begun each time this heaviest ion reached the detector? 30000 spectra/s 10000 spectra/s 11000 spectra/s 500 spectra/s 22000 spectra/sarrow_forwardThe ppm concentration of Pb2+ in a blood sample were measured with Spectrophotometry. 5.00 mL of a blood sample were taken and this sample gave a signal of 0.301 a.u.. Another 5.00 mL of a blood sample were mixed with 0.50 mL og 1.75 ppm Pb2+. Then, this mixture was diluted to 25.00 mL and this diluted mixture gave a signal of 0.406 a.u.. What is the ppm concentration of a blood sample?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning