Principles of Instrumental Analysis
7th Edition
ISBN: 9781305577213
Author: Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Question
Chapter 11, Problem 11.5QAP
Interpretation Introduction
Interpretation:
The reason for ICPMS to be an important and widely used analytical method needs to be explained.
Concept introduction:
ICPMS is a kind of
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
What is the purpose of a calibration curve in analytical chemistry?
Briefly explain method validation in analytical chemistry? Discuss typical validation characteristics which could be considered. Name some international organisations offering guidelines on method
validation
What are method blanks and method detection limit used in analytical chemistry? Explain thoroughly
Chapter 11 Solutions
Principles of Instrumental Analysis
Knowledge Booster
Similar questions
- use analytical separation and analyses to outline analytical separation method protocols that can be employed to recover extremely high deposit of heavy metals and particulate matter in the river making wholesome for drinking in illegal mining communities .arrow_forwardDiscuss three practical applications of solvent extraction in analytical chemistry.arrow_forwardGas Chromatography (GC) is one of the useful techniques in analytical chemistry. Give two important components in GC.arrow_forward
- What are the advantages and disadvantages of volumetric and gravimetric analysis?arrow_forwardWhat are the differences between systematic and random errors and how do they effect accuracy and precision? In what circumstances would you use standard addition (versus a normal calibration curve) to determine the amount of an analyte in a sample? A urine sample, containing analyte Z is analysed by the standard addition method where 5 mL of the original sample was mixed with increasing amounts of a Z standard and each solution diluted to a volume of 50 mL prior to analysis. A plot of the final concentration of the standard in each of the 50 mL samples (x axis) versus The measured signal from the analysis of each 50 mL sample (on y axis) produced a straight line with the general equation: y = 44.72x + 4.06 what was the final concentration of Z in the 50 mL standard addition sample? what was the initial concentration of Z in the original urine sample?arrow_forwardDifferentiate between qualitative analysis and quantitive analysis?arrow_forward
- Can paper chromatography be used to separate and identify very volatile substances? Why? Please explain comprehensively.arrow_forwardOne method for the quantitative determination of the concentration of constituents in a sample analyzed by gas chromatography is area normalization. Here, complete elution of all the sample constituents is necessary. The area of each peak is then measured and corrected for differences in detector response to the different eluates. This correction involves dividing the area by an empirically determined correction factor. The concentration of the analyte is found from the ratio of its corrected area to the total corrected area of all peaks. For a chromatogram containing three peaks, the relative areas were found to be 16.4, 45.2 and 30.2, in order of increasing retention time. Calculate the percentage of each compound if the relative detector responses were 0.60, 0.78 and 0.88, respectively.arrow_forwardExplain the differences between the following calibration methods and why they are needed. a) External standard; b) Standard addition; c) Internal standardarrow_forward
- What is the importance of the following analytical methods in chemical analysis? i. UV-vis spectrophotometry ii. HPLC iii. GCarrow_forwardList three typical examples applications of SFC analysis.arrow_forwardThe amount of caffeine in an analgesic tablet was determined by HPLC using a normal calibration curve. Standard solutions of caffeine were prepared and analyzed using a 10-µL fixed-volume injection loop. Results for the standards are summarized in the following table. Concentration of Standards Signal (arbitrary units) (ppm) 50.0 8354 100.0 16925 150.0 25218 200.0 33584 250.0 42002 The sample was prepared by placing a single analgesic tablet in a small beaker and adding 10 mL of methanol. After allowing the sample to dissolve, the contents of the beaker, including the insoluble binder, were quantitatively transferred to a 25-mL volumetric flask and diluted to volume with methanol. The sample was then filtered, and a 1.00-mL aliquot was transferred to a 10-mL volumetric flask and diluted to volume with methanol. When analyzed by HPLC, the signal for the caffeine was found to be 21469. Report the number of milligrams of caffeine in the analgesic tablet.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning