With the principles of GFC, which of the following statements is incorrect? a. For small molecules, their elution volume, Ve > VO b. For a very large molecule, its elution volume, Ve = Vo c. Blue dextran is used to determine the void volume because it is too large  and cannot get into the beads and therefore excluded from the gel. d. Low molecular weight molecules are freely accessible to the gel particles,  and elute at a volume equal to the internal pore volume. In an SDS-PAGE experiment, protein X has an Rf = 0.75, while protein Y has an Rf  = 0.30. Which of the following statements are FALSE during the electrophoretic  run? I. X has a greater charge-to-mass ratio than Y, since X has a smaller MW. II. X has a lower MW, and thus experiences less friction with the gel matrix. III. X has more hydrophobic groups, thus is in a more linearized state. IV. X is globular, while protein Y is rod-like, thus X has higher mobility. V. X is affected by less magnitude of electric field because of smaller MW. a. I and V b. II and IV c. II, III, and IV d. I, III, IV, and V

Biochemistry
9th Edition
ISBN:9781319114671
Author:Lubert Stryer, Jeremy M. Berg, John L. Tymoczko, Gregory J. Gatto Jr.
Publisher:Lubert Stryer, Jeremy M. Berg, John L. Tymoczko, Gregory J. Gatto Jr.
Chapter1: Biochemistry: An Evolving Science
Section: Chapter Questions
Problem 1P
icon
Related questions
Question

With the principles of GFC, which of the following statements is incorrect?
a. For small molecules, their elution volume, Ve > VO
b. For a very large molecule, its elution volume, Ve = Vo
c. Blue dextran is used to determine the void volume because it is too large 
and cannot get into the beads and therefore excluded from the gel.
d. Low molecular weight molecules are freely accessible to the gel particles, 
and elute at a volume equal to the internal pore volume.

In an SDS-PAGE experiment, protein X has an Rf = 0.75, while protein Y has an Rf 
= 0.30. Which of the following statements are FALSE during the electrophoretic 
run?
I. X has a greater charge-to-mass ratio than Y, since X has a smaller MW.
II. X has a lower MW, and thus experiences less friction with the gel matrix.
III. X has more hydrophobic groups, thus is in a more linearized state.
IV. X is globular, while protein Y is rod-like, thus X has higher mobility.
V. X is affected by less magnitude of electric field because of smaller MW.
a. I and V
b. II and IV
c. II, III, and IV
d. I, III, IV, and V

Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Biochemistry
Biochemistry
Biochemistry
ISBN:
9781319114671
Author:
Lubert Stryer, Jeremy M. Berg, John L. Tymoczko, Gregory J. Gatto Jr.
Publisher:
W. H. Freeman
Lehninger Principles of Biochemistry
Lehninger Principles of Biochemistry
Biochemistry
ISBN:
9781464126116
Author:
David L. Nelson, Michael M. Cox
Publisher:
W. H. Freeman
Fundamentals of Biochemistry: Life at the Molecul…
Fundamentals of Biochemistry: Life at the Molecul…
Biochemistry
ISBN:
9781118918401
Author:
Donald Voet, Judith G. Voet, Charlotte W. Pratt
Publisher:
WILEY
Biochemistry
Biochemistry
Biochemistry
ISBN:
9781305961135
Author:
Mary K. Campbell, Shawn O. Farrell, Owen M. McDougal
Publisher:
Cengage Learning
Biochemistry
Biochemistry
Biochemistry
ISBN:
9781305577206
Author:
Reginald H. Garrett, Charles M. Grisham
Publisher:
Cengage Learning
Fundamentals of General, Organic, and Biological …
Fundamentals of General, Organic, and Biological …
Biochemistry
ISBN:
9780134015187
Author:
John E. McMurry, David S. Ballantine, Carl A. Hoeger, Virginia E. Peterson
Publisher:
PEARSON