Q7// 11-MW steam power plant of overall efficiency of 32% is operating using coal (33 MJ/kg) as a fuel. The plant utilizes a steam generator that produces steam at 40bar and 300 °C at a rate of 10.5 kg/s. The temperature of the feed water is raised from 40 °C to 125 °C in the economizer and the ambient air is drawn to the boiler at a rate of 16 kg/s at 20 °C. The temperature of flue gases (Cp=1 kJ/kg.K) leaving the chimney is 160 °C and the dryness fraction of steam collected in the steam drum is 0.95. Determine the boiler efficiency and set the heat balance sheet(all in kJ/kgf). Answ( 85.4%, 12.5kg steam/kg fuel, 39.6%, Eeco -3597kJ/kgf, Eeva=22064.7kJ/kgf, Esup=2495.5 kJ/kgf, Eexh=2289.7 kJ/kg)

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question
Q7// 11-MW steam power plant of overall efficiency of 32% is operating using coal (33 MJ/kg) as a fuel.
The plant utilizes a steam generator that produces steam at 40bar and 300 °C at a rate of 10.5 kg/s. The
temperature of the feed water is raised from 40 °C to 125 °C in the economizer and the ambient air is
drawn to the boiler at a rate of 16 kg/s at 20 °C. The temperature of flue gases (Cp=1 kJ/kg.K) leaving
the chimney is 160 °C and the dryness fraction of steam collected in the steam drum is 0.95. Determine
the boiler efficiency and set the heat balance sheet(all in kJ/kgf). Answ( 85.4%, 12.5kg steam/kg fuel,
39.6%, Eeco -3597kJ/kgf, Eeva=22064.7kJ/kgf, Esup=2495.5 kJ/kgf, Eexh=2289.7 kJ/kg)
Transcribed Image Text:Q7// 11-MW steam power plant of overall efficiency of 32% is operating using coal (33 MJ/kg) as a fuel. The plant utilizes a steam generator that produces steam at 40bar and 300 °C at a rate of 10.5 kg/s. The temperature of the feed water is raised from 40 °C to 125 °C in the economizer and the ambient air is drawn to the boiler at a rate of 16 kg/s at 20 °C. The temperature of flue gases (Cp=1 kJ/kg.K) leaving the chimney is 160 °C and the dryness fraction of steam collected in the steam drum is 0.95. Determine the boiler efficiency and set the heat balance sheet(all in kJ/kgf). Answ( 85.4%, 12.5kg steam/kg fuel, 39.6%, Eeco -3597kJ/kgf, Eeva=22064.7kJ/kgf, Esup=2495.5 kJ/kgf, Eexh=2289.7 kJ/kg)
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY