Q3: The Figure shown a HPLC chromatogram of two compound.Calculate the following values using the data in this chromatogram. Detector signal a. The adjusted retention time of uracil and guanine. b. The peak widths for uracil and guanine. c. The retention factor for uracil and guanine. d. The selectivity factor for uracil and guanine. e. The resolution for these two compounds. f. The column efficiency parameters, N and H, if the column length is 10cm. 0.6- 05- 04 03- 02- 0.1 15 30 45.0 s void 45 60 76 كليل الك 90 1800 s uracil 247.5s guanine 105 120 135 150 166 180 195 210 225 240 255 270 296 Time, seconds

Chemistry
10th Edition
ISBN:9781305957404
Author:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Chapter1: Chemical Foundations
Section: Chapter Questions
Problem 1RQ: Define and explain the differences between the following terms. a. law and theory b. theory and...
icon
Related questions
Question
كرة HPLC
Q3: The Figure shown a HPLC chromatogram of two compound .Calculate the
following values using the data in this chromatogram.
Detector signal
a. The adjusted retention time of uracil and guanine.
b. The peak widths for uracil and guanine.
The retention factor for uracil and guanine.
C.
d.
The selectivity factor for uracil and guanine.
e. The resolution for these two compounds.
f. The column efficiency parameters, N and H, if the column length is 10cm.
0.6-
05
04
03
0.2
0.1-
45.0 s
vold
A
15 30 45
تختبر تحليل الى
180.0 s
Auracil
90
60 76
2475s
guanine
105-120 135 150 166 180 195 210 225 240 255 270 296
Time, seconds
Transcribed Image Text:كرة HPLC Q3: The Figure shown a HPLC chromatogram of two compound .Calculate the following values using the data in this chromatogram. Detector signal a. The adjusted retention time of uracil and guanine. b. The peak widths for uracil and guanine. The retention factor for uracil and guanine. C. d. The selectivity factor for uracil and guanine. e. The resolution for these two compounds. f. The column efficiency parameters, N and H, if the column length is 10cm. 0.6- 05 04 03 0.2 0.1- 45.0 s vold A 15 30 45 تختبر تحليل الى 180.0 s Auracil 90 60 76 2475s guanine 105-120 135 150 166 180 195 210 225 240 255 270 296 Time, seconds
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Analytical Separations
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Chemistry
Chemistry
Chemistry
ISBN:
9781305957404
Author:
Steven S. Zumdahl, Susan A. Zumdahl, Donald J. DeCoste
Publisher:
Cengage Learning
Chemistry
Chemistry
Chemistry
ISBN:
9781259911156
Author:
Raymond Chang Dr., Jason Overby Professor
Publisher:
McGraw-Hill Education
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning
Organic Chemistry
Organic Chemistry
Chemistry
ISBN:
9780078021558
Author:
Janice Gorzynski Smith Dr.
Publisher:
McGraw-Hill Education
Chemistry: Principles and Reactions
Chemistry: Principles and Reactions
Chemistry
ISBN:
9781305079373
Author:
William L. Masterton, Cecile N. Hurley
Publisher:
Cengage Learning
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemistry
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY