Q1:- A 3-phase induction motor has an output a 37KW at this load the stator copper loss and rotor copper loss each equal the stator iron loss. The mechanical losses are one - third of on load loss. Calculate the slip at this load ? when efficiency = 90%

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
أسئلة سنوات سابقة
Q1:- A 3-phase induction motor has an output a 37KW at this load the stator
copper loss and rotor copper loss each equal the stator iron loss. The
mechanical losses are one - third of on load loss. Calculate the slip at this
load ? when efficiency = 90%
Q2 :- A 3-phase, 4 pole, 50 Hz , slip ring I.M it is full load speed is 1440 rpm if
the rotor resistance is 0.25 ohm/phase. Find the value external resistance to
be connected to the rotor winding to reduce speed to 1200 rpm ( the torque
is remain constant)
Q3:- A 3-phase, 4 pole, 400 V , 50HZ , 20KW , IM , it is full load speed is 1470
rpm at critical slip the rotor copper losses increased 8 times compared with
full load value find Mm and Ms ( neglect Z1 and Pfw )
Q4:- 3-phase, 6 pole, 400V 50HZ , I.M , has the stand still impedance of
( 0.04 +j 0.44 ) ohm/phase and emf between open slip ring 100 . Find Ms ,
output power , Torque .when Mm = 2
Q5:- A 3-phase, 8 pole, 380 V , 50HZ , I.M it is stator winding is delta
connected and rotor Y-connected with T1/T2 = 2 if Z1=Z2= 0.3 + j2.5 .find
1- Developed torque at 735 rpm
2- The addition resistance to be added to rotor winding to reduce the
rotor speed to 675 rpm at the same torque.
Q6- A 6-pole generator having a 3-phase ,star connected winding. To
induce a line voltage of ( 3300 V ) at no load if required flux of 33.15 mWb/pol
at 50 HZ frequency. Find total number of slot and the number of conductor
per slot if the slot pitch is 20 and coils of full span
Q7:- A 3-phase, 4 pole, I.M,developing a maximum torque at speed 1320
rpm .The resistance of star connected winding is 0.3 ohm/phase. Determine
the value of the resistance of be connected to the rotor winding make the
starting torque 60% of maximum torque
Q8:- A 3-phase,6ploe ,400V,50HZ,I.M, it is rotor winding
Transcribed Image Text:أسئلة سنوات سابقة Q1:- A 3-phase induction motor has an output a 37KW at this load the stator copper loss and rotor copper loss each equal the stator iron loss. The mechanical losses are one - third of on load loss. Calculate the slip at this load ? when efficiency = 90% Q2 :- A 3-phase, 4 pole, 50 Hz , slip ring I.M it is full load speed is 1440 rpm if the rotor resistance is 0.25 ohm/phase. Find the value external resistance to be connected to the rotor winding to reduce speed to 1200 rpm ( the torque is remain constant) Q3:- A 3-phase, 4 pole, 400 V , 50HZ , 20KW , IM , it is full load speed is 1470 rpm at critical slip the rotor copper losses increased 8 times compared with full load value find Mm and Ms ( neglect Z1 and Pfw ) Q4:- 3-phase, 6 pole, 400V 50HZ , I.M , has the stand still impedance of ( 0.04 +j 0.44 ) ohm/phase and emf between open slip ring 100 . Find Ms , output power , Torque .when Mm = 2 Q5:- A 3-phase, 8 pole, 380 V , 50HZ , I.M it is stator winding is delta connected and rotor Y-connected with T1/T2 = 2 if Z1=Z2= 0.3 + j2.5 .find 1- Developed torque at 735 rpm 2- The addition resistance to be added to rotor winding to reduce the rotor speed to 675 rpm at the same torque. Q6- A 6-pole generator having a 3-phase ,star connected winding. To induce a line voltage of ( 3300 V ) at no load if required flux of 33.15 mWb/pol at 50 HZ frequency. Find total number of slot and the number of conductor per slot if the slot pitch is 20 and coils of full span Q7:- A 3-phase, 4 pole, I.M,developing a maximum torque at speed 1320 rpm .The resistance of star connected winding is 0.3 ohm/phase. Determine the value of the resistance of be connected to the rotor winding make the starting torque 60% of maximum torque Q8:- A 3-phase,6ploe ,400V,50HZ,I.M, it is rotor winding
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Single Phase Induction Motor
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,