There are 72 slots in a 3-phase, 8-pole, 50 Hz, star connected alternator. There are 2 conductors in each slot and all the conductors in a phase are connected in series. Coil span is 150° electrical and the flux per pole is 0.05 Weber sinusoidally distributed. Calculate the emf induced per phase.
Synchronous Generator
In comparison to an asynchronous generator, it is a machine where the rotor speed is equal to the rotating magnetic field produced by the stator, i.e., mechanical speed is equal to the electrical speed, thus called synchronous, and not asynchronous.
Salient Pole Rotor
Salient pole rotor includes a large number of exposed poles mounted on a magnetic wheel. The construction of a bright pole is as shown in the image on the left. The proposed poles are made of metal laminations. The rotor winding is provided on these poles and is supported by pole shoes.
There are 72 slots in a 3-phase, 8-pole, 50 Hz, star connected alternator. There are 2 conductors in each slot and all the conductors in a phase are connected in series. Coil span is 150° electrical and the flux per pole is 0.05 Weber sinusoidally distributed. Calculate the emf induced per phase.
Step by step
Solved in 2 steps with 2 images