PV station 8.6 Consider the microgrid given in Figure 8.56. The positive sequence impedance of the transmission lines is given in the one-line diagram (Figure 8.56). The system data are as follows: PV generating station: 2 MW, 460 V AC; positive, negative, and zero sequence impedance of each line is equal to 10%. The gas turbine gen- erating station is rated at 10 MVA, 3.2 kV, with positive sequence reac- tance of 10%. The generator negative sequence impedance is equal to the positive sequence, and the zero sequence impedance is equal to half (1/2) of the positive sequence impedance. Transformers' positive sequence impedance is equal to the negative sequence and equal to the zero sequence impedance. DC/AC 3 CB T₁ AC PV bus YA 6 1+/10 20 CB CB CB m 0.5+15 личи 5 A S5 2 Gas turbine 0.3+16 7 ww NA Local S6 ST utility Figure 8.56 A one-line diagram for Problem 8.6.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter8: Symmetrical Components
Section: Chapter Questions
Problem 8.23P
icon
Related questions
Question
PV
station
8.6 Consider the microgrid given in Figure 8.56.
The positive sequence impedance of the transmission lines is given in
the one-line diagram (Figure 8.56). The system data are as follows:
PV generating station: 2 MW, 460 V AC; positive, negative, and zero
sequence impedance of each line is equal to 10%. The gas turbine gen-
erating station is rated at 10 MVA, 3.2 kV, with positive sequence reac-
tance of 10%. The generator negative sequence impedance is equal to
the positive sequence, and the zero sequence impedance is equal to half
(1/2) of the positive sequence impedance. Transformers' positive
sequence impedance is equal to the negative sequence and equal to
the zero sequence impedance.
DC/AC
3
CB
T₁
AC PV bus YA
6
1+/10
20
CB
CB
CB
m
0.5+15
личи
5
A
S5
2
Gas
turbine
0.3+16
7 ww
NA
Local
S6
ST
utility
Figure 8.56 A one-line diagram for Problem 8.6.
Transcribed Image Text:PV station 8.6 Consider the microgrid given in Figure 8.56. The positive sequence impedance of the transmission lines is given in the one-line diagram (Figure 8.56). The system data are as follows: PV generating station: 2 MW, 460 V AC; positive, negative, and zero sequence impedance of each line is equal to 10%. The gas turbine gen- erating station is rated at 10 MVA, 3.2 kV, with positive sequence reac- tance of 10%. The generator negative sequence impedance is equal to the positive sequence, and the zero sequence impedance is equal to half (1/2) of the positive sequence impedance. Transformers' positive sequence impedance is equal to the negative sequence and equal to the zero sequence impedance. DC/AC 3 CB T₁ AC PV bus YA 6 1+/10 20 CB CB CB m 0.5+15 личи 5 A S5 2 Gas turbine 0.3+16 7 ww NA Local S6 ST utility Figure 8.56 A one-line diagram for Problem 8.6.
Expert Solution
steps

Step by step

Solved in 2 steps with 20 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning