B2. An office, 12m x 5m x 3.5m (W×L×H) in dimension using 600mm x 600mm ceiling tiles, is to be illuminated by 4 × 36W 1200 luminaires, mounted at ceiling. The required lighting level is 500 lux. Assuming the working plane is at 0.8m AFFL. Maintenance factor is 0.8 and the ratio of reflectances at ceiling, wall and floor are 0.7, 0.5 and 0.2. Each 36W lamp gives a light output of 3000 lm. (Note: AFFL is Above Finished Floor Level) Light Output Ratio Up 0.45 Max. Spacing to Height Ratio Down 0.35 SHR MAX 1.79 Total 0.80 SHR MAX TR 2.20 Utilization Factors UF (F) SHR NOM = 1.75 Reflectances Room Index C W F 0.70 0.50 0.20 0.30 0.29 0.10 0.25 0.50 0.50 0.20 0.29 0.34 0.38 0.41 0.45 0.30 0.24 0.30 0.34 0.37 0.42 0.10 0.21 0.27 0.31 0.34 0.30 0.50 0.20 0.24 0.28 0.31 0.34 0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00 0.34 0.41 0.46 0.50 0.55 0.58 0.61 0.64 0.66 0.35 0.40 0.44 0.50 0.54 0.57 0.61 0.63 0.31 0.36 0.40 0.46 0.50 0.53 0.58 0.61 0.48 0.50 0.45 0.47 0.50 0.53 0.39 0.42 0.45 0.48 0.51 0.40 0.53 0.55 0.37 0.39 0.43 0.44 0.30 0.10 0.20 0.25 0.28 0.31 0.34 0.37 0.38 0.41 0.42 0.18 0.23 0.26 0.28 0.32 0.35 0.37 0.39 0.41 0.00 0.00 0.00 0.12 0.16 0.18 0.19 0.22 0.23 0.25 0.26 0.28

EBK ELECTRICAL WIRING RESIDENTIAL
19th Edition
ISBN:9781337516549
Author:Simmons
Publisher:Simmons
Chapter33: Residential Utility-interactive Photovoltaic Systems
Section: Chapter Questions
Problem 6R: To size conductors and overcurrent devices for source circuits, you must multiply the module string...
icon
Related questions
Question

Questions:

a) Calculate the minimum number of luminaires required to achieve the required lighting level.
b) Calculate the final lighting level based upon the result at B2 (a).
c) Propose a suitable lighting arrangement column x row
d) Sketch the lighting layout according to the result at B2 (c).
e) Calculate the space-to height ratio(s) and comment on the result.

B2.
An office, 12m x 5m x 3.5m (W×L×H) in dimension using
600mm x 600mm ceiling tiles, is to be illuminated by 4 × 36W
1200 luminaires, mounted at ceiling. The required lighting level is 500
lux. Assuming the working plane is at 0.8m AFFL. Maintenance factor is
0.8 and the ratio of reflectances at ceiling, wall and floor are 0.7, 0.5 and
0.2. Each 36W lamp gives a light output of 3000 lm. (Note: AFFL is
Above Finished Floor Level)
Light Output Ratio
Up 0.45
Max. Spacing to Height Ratio
Down 0.35
SHR MAX 1.79
Total 0.80
SHR MAX TR 2.20
Utilization Factors UF (F)
SHR NOM = 1.75
Reflectances
Room Index
C
W
F
0.70
0.50 0.20
0.30
0.29
0.10
0.25
0.50 0.50 0.20
0.29
0.34
0.38
0.41 0.45
0.30
0.24
0.30
0.34
0.37
0.42
0.10
0.21
0.27
0.31
0.34
0.30
0.50 0.20
0.24
0.28 0.31
0.34
0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00
0.34 0.41 0.46 0.50 0.55 0.58 0.61 0.64 0.66
0.35 0.40 0.44 0.50 0.54 0.57 0.61 0.63
0.31 0.36 0.40 0.46 0.50 0.53
0.58 0.61
0.48 0.50
0.45 0.47 0.50 0.53
0.39 0.42 0.45 0.48 0.51
0.40
0.53 0.55
0.37
0.39
0.43 0.44
0.30
0.10
0.20 0.25 0.28 0.31
0.34
0.37 0.38
0.41
0.42
0.18 0.23 0.26 0.28
0.32
0.35
0.37
0.39
0.41
0.00 0.00 0.00
0.12
0.16
0.18
0.19
0.22
0.23
0.25 0.26 0.28
Transcribed Image Text:B2. An office, 12m x 5m x 3.5m (W×L×H) in dimension using 600mm x 600mm ceiling tiles, is to be illuminated by 4 × 36W 1200 luminaires, mounted at ceiling. The required lighting level is 500 lux. Assuming the working plane is at 0.8m AFFL. Maintenance factor is 0.8 and the ratio of reflectances at ceiling, wall and floor are 0.7, 0.5 and 0.2. Each 36W lamp gives a light output of 3000 lm. (Note: AFFL is Above Finished Floor Level) Light Output Ratio Up 0.45 Max. Spacing to Height Ratio Down 0.35 SHR MAX 1.79 Total 0.80 SHR MAX TR 2.20 Utilization Factors UF (F) SHR NOM = 1.75 Reflectances Room Index C W F 0.70 0.50 0.20 0.30 0.29 0.10 0.25 0.50 0.50 0.20 0.29 0.34 0.38 0.41 0.45 0.30 0.24 0.30 0.34 0.37 0.42 0.10 0.21 0.27 0.31 0.34 0.30 0.50 0.20 0.24 0.28 0.31 0.34 0.75 1.00 1.25 1.50 2.00 2.50 3.00 4.00 5.00 0.34 0.41 0.46 0.50 0.55 0.58 0.61 0.64 0.66 0.35 0.40 0.44 0.50 0.54 0.57 0.61 0.63 0.31 0.36 0.40 0.46 0.50 0.53 0.58 0.61 0.48 0.50 0.45 0.47 0.50 0.53 0.39 0.42 0.45 0.48 0.51 0.40 0.53 0.55 0.37 0.39 0.43 0.44 0.30 0.10 0.20 0.25 0.28 0.31 0.34 0.37 0.38 0.41 0.42 0.18 0.23 0.26 0.28 0.32 0.35 0.37 0.39 0.41 0.00 0.00 0.00 0.12 0.16 0.18 0.19 0.22 0.23 0.25 0.26 0.28
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
EBK ELECTRICAL WIRING RESIDENTIAL
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:
9781337516549
Author:
Simmons
Publisher:
CENGAGE LEARNING - CONSIGNMENT
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning