An electric supply company having a maximum load of 50 MW generates 18x 10^7 units per annum and the supply consumers have an aggregate demand of 75 MW. The annual expenses including capital charges are: For fuel = Rs 90 lakhs Fixed charges concerning generation = Rs 28 lakhs Fixed charges concerning transmission= Rs 32 lakhs and distribution Assuming 90% of the fuel cost is essential to running charges and the loss in transmission and distribution as 15% of kWh generated, deduce a two part tariff to find the actual cost of supply to the consumers.
Short Transmission Line
A short transmission line is a transmission line that has a length less than 80 kilometers, an operating voltage level of less than 20 kV, and zero capacitance effect.
Power Flow Analysis
Power flow analysis is a topic in power engineering. It is the flow of electric power in a system. The power flow analysis is preliminary used for the various components of Alternating Current (AC) power, such as the voltage, current, real power, reactive power, and voltage angles under given load conditions and is often known as a load flow study or load flow analysis.
Complex Form
A power system is defined as the connection or network of the various components that convert the non-electrical energy into the electric form and supply the electric form of energy from the source to the load. The power system is an important parameter in power engineering and the electrical engineering profession. The powers in the power system are primarily categorized into two types- active power and reactive power.
I need Full answer with details solution
An electric supply company having a maximum load of 50 MW generates 18x 10^7 units per annum and the supply consumers have an aggregate demand of 75 MW. The annual expenses including capital charges are:
For fuel = Rs 90 lakhs
Fixed charges concerning generation = Rs 28 lakhs
Fixed charges concerning transmission= Rs 32 lakhs and distribution
Assuming 90% of the fuel cost is essential to running charges and the loss in transmission and distribution as 15% of kWh generated, deduce a two part tariff to find the actual cost of supply to the consumers.
Step by step
Solved in 3 steps