1.3 For the radial power system shown in Figure 1.17, calculate the line-to-ground fault current flowing in each of the circuit breakers for faults at each of the buses. The system data are given in the accompanying table. Also determine the corresponding faulted phase voltage, assuming that the generator is ideal, with a terminal voltage of 1.0 pu. 1 2 3 4 5 6 中 + 中 + H B₁₁ B2 B3 B4 B5 Figure 1.17 Problem 1.3 System data for Figure 1.17 From To Positive sequence Zero sequence 23456 12345 impedance 0.01 +j0.05 3 0.003 + j0.04 0.008+ j0.04 0.01 + j0.05 0.003+j0.02 6 0.04 + j0.15 0.03+j0.15 0.01 + j0.06 impedance 0.02 + j0.13 0.01 + j0.16

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter8: Symmetrical Components
Section: Chapter Questions
Problem 8.34P
icon
Related questions
Question
Explain in each detail this question
1.3 For the radial power system shown in Figure 1.17, calculate the line-to-ground fault current
flowing in each of the circuit breakers for faults at each of the buses. The system data are
given in the accompanying table. Also determine the corresponding faulted phase voltage,
assuming that the generator is ideal, with a terminal voltage of 1.0 pu.
1
2
3
4
5
6
中
+
中
+
H
B₁₁
B2
B3
B4
B5
Figure 1.17 Problem 1.3
System data for Figure 1.17
From
To
Positive sequence
Zero sequence
23456
12345
impedance
0.01 +j0.05
3 0.003 + j0.04
0.008+ j0.04
0.01 + j0.05
0.003+j0.02
6
0.04 + j0.15
0.03+j0.15
0.01 + j0.06
impedance
0.02 + j0.13
0.01 + j0.16
Transcribed Image Text:1.3 For the radial power system shown in Figure 1.17, calculate the line-to-ground fault current flowing in each of the circuit breakers for faults at each of the buses. The system data are given in the accompanying table. Also determine the corresponding faulted phase voltage, assuming that the generator is ideal, with a terminal voltage of 1.0 pu. 1 2 3 4 5 6 中 + 中 + H B₁₁ B2 B3 B4 B5 Figure 1.17 Problem 1.3 System data for Figure 1.17 From To Positive sequence Zero sequence 23456 12345 impedance 0.01 +j0.05 3 0.003 + j0.04 0.008+ j0.04 0.01 + j0.05 0.003+j0.02 6 0.04 + j0.15 0.03+j0.15 0.01 + j0.06 impedance 0.02 + j0.13 0.01 + j0.16
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning