Textbook Question
Chapter 52, Problem 7SQ
How tightly should V-belts be adjusted?
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
A factory has the following load with power factor of 0.85 lagging in each phase.
Between the red and yellow phases 40 A, between the yellow and blue phases 50 A,
and between the blue and red phases 60 A. If the supply is 415 V, three-phase,
calculate the line currents. Draw a phasor diagram for phase and line quantities. Ensure to draw all necessary diagrams
ANS: IR
= 87.178<-68.380 A; IY = 78.102<-178.120 A; IB = 95.394<61.210 A.
Answer question D only using by hand
first darw cylinder then calculate show me st
The phase currents in a delta-connected three-phase
load are as follows: between the red and yellow lines,
30 A at p.f. 0.707 leading; between the yellow and blue
lines, 20 A at unity p.f.; between the blue and red
lines, 25 A at p.f. 0.866 lagging. Calculate the line
currents and draw the complete phasor diagram.
ANS:
21.6 A in R, 49.6 A in Y, 43.5 A in B
Chapter 52 Solutions
Electric Motor Control
Ch. 52 - What are the disadvantages of low-speed, directly...Ch. 52 - What type of AC motor can be directly coupled at...Ch. 52 - What three alignment checks should be made to...Ch. 52 - What special tools, not ordinarily carried by an...Ch. 52 - Prob. 5SQCh. 52 - Prob. 6SQCh. 52 - How tightly should V-belts be adjusted?Ch. 52 - Prob. 8SQCh. 52 - A machine delivered for installation has a 2-inch...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- . Two wattmeters connected to measure the input to a balanced three-phase circuit indicate 2500 W and 500 W respectively. Find the power factor of the circuit: (a) when both readings are positive; (b) when the latter reading is obtained after reversing the con nections to the current-coil of one instrument. Draw the phasor and connection diagrams. ANS: 0.655, 0.359arrow_forwardExplain the advantage of connecting the low-voltage winding of distribution transformers in star. A factory has the following load with power factor of 0.9 lagging in each phase. Red phase 40 A, yellow phase 50 A and blue phase 60 A. If the supply is 400 V, three phase, four-wire, calculate the current in the neutral and the total active power. Draw a phasor diagram for phase and line quantities. Assume that, relative to the current in the red phase, the current in the yellow phase lags by 120° and that in the blue phase leads by 120°. ANS: 17.3 A, 31.2 kWarrow_forwardA three-phase, 400 V system has the following load connected in delta: between the red and yellow lines, a non-reactive resistor of 100 Ω; between the yellow and blue lines, a coil having a reactance of 60 Ω and negligible resistance; between the blue and red lines, a loss-free capacitor having a reactance of 130 Ω. Calculate: (a) the phase currents; (b) the line currents. Assume the phase sequence to be R–Y, Y–B and B–R. Also, draw the complete phasor diagram. ANS: 4.00 A, 6.67 A, 3.08 A, 6.85 A, 10.33 A, 5.8 Aarrow_forward
- With the aid of a circuit diagram, show that two wattmeters can be connected to read the total power in a three-phase, three-wire system. Two wattmeters connected to read the total power in a three-phase system supplying a balanced load read 10.5 kW and −2.5 kW respectively. Calculate the total active power. Drawing suitable phasor diagrams, explain the significance of: (a) equal wattmeter readings; (b) a zero reading on one wattmeter. ANS: 8 kWarrow_forwardA factory has the following load with power factor of 0.9 lagging in each phase. Red phase 40 A, yellow phase 50 A and blue phase 60 A. If the supply is 400 V, three-phase, four-wire, calculate the current in the neutral and the total active power. Draw a phasor diagram for phase and line quantities. Assume that, relative to the current in the red phase, the current in the yellow phase lags by 120° and that in the blue phase leads by 120°.arrow_forwardFundimentals of Energy Systems Q8arrow_forward
- Two wattmeters are used to measure power in a three phase, three-wire network. Show by means of connection and complexor (phasor) diagrams that the sum of the wattmeter readings will measure the total active power. Two such wattmeters read 120 W and 50 W when connected to measure the active power taken by a balanced three-phase load. Find the power factor of the load. If one wattmeter tends to read in the reverse direction, explain what changes may have occurred in the circuit ANS: 0.815arrow_forwardFundimentals of Energy Systems Q7arrow_forwardFundimentals of Energy Systems Q6arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Electricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage LearningEBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
- Delmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage Learning
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
Single Phase Induction Motor, How it works ?; Author: Lesics;https://www.youtube.com/watch?v=awrUxv7B-a8;License: Standard Youtube License