Electrical Wiring Residential
18th Edition
ISBN: 9781285170954
Author: Ray C. Mullin, Phil Simmons
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Question
Chapter 4, Problem 15R
To determine
List the differences between Type AC and Type ACT armored cables.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Service-lateral conductors are required to be insulated except for the grounded neutral conductor when it is___.
A. Bare copper used in a raceway
B. Bare copper & part of a cable assembly that is identified for ground use
C. copper-clad Aluminum
D. A or B
19. What size copper bonding jumper must be used in an AC electrical system that has 500 kcmil copper phase conductors?
A. 4/0 B. 1/0 C. 2/0 D. 3/0
20. A neutral disconnect link is usually in the form of a _______ in larger service equipment. A. screwB. wireC. clamp
D. busbar
11. Specific rules apply for the installation of _______, but no identification requirements for them exists.A. grounding electrode conductorsB. grounding electrodes.C. main bonding jumpers.D. equipment grounding conductors.
Chapter 4 Solutions
Electrical Wiring Residential
Ch. 4 - The largest size solid conductor generally...Ch. 4 - What is the minimum branch-circuit wire size that...Ch. 4 - What exceptions, if any, are there to the answer...Ch. 4 - What determines the ampacity of a wire?Ch. 4 - What unit of measurement is used for the diameter...Ch. 4 - What unit of measurement is used for the...Ch. 4 - What is the voltage rating of the conductors in...Ch. 4 - Indicate the allowable ampacity of the following...Ch. 4 - Prob. 9RCh. 4 - What are the colors of the conductors in...
Ch. 4 - For nonmetallic-sheathed cable, may the...Ch. 4 - Prob. 12RCh. 4 - Under what condition may nonmetallic-sheathed...Ch. 4 - a. What is the maximum distance permitted between...Ch. 4 - Prob. 15RCh. 4 - Prob. 16RCh. 4 - Prob. 17RCh. 4 - Prob. 18RCh. 4 - Prob. 19RCh. 4 - Circle the correct answer to the following...Ch. 4 - When running Type NM cable through a bored hole in...Ch. 4 - Where is the main service-entrance panel located...Ch. 4 - Is it permitted to use flexible metal conduit over...Ch. 4 - Liquidtight flexible metal conduit may serve as a...Ch. 4 - It is permissible for an electrician to connect...Ch. 4 - Terminals of switches and receptacles marked...Ch. 4 - Wire connectors marked AL/CU are suitable for use...Ch. 4 - A wire connector bearing no marking or reference...Ch. 4 - When Type NM cable is run through a floor, it must...Ch. 4 - When nonmetallic-sheathed cables are bunched or...Ch. 4 - In diagrams A and B, nonmetallic-sheathed cable is...Ch. 4 - The marking on the outer jacket of a...Ch. 4 - A 120-volt branch circuit supplies a resistive...Ch. 4 - In problem 35, it is desired to keep the voltage...Ch. 4 - Prob. 37RCh. 4 - The allowable ampacity of a 4 AWG THHN from Table...Ch. 4 - If, because of some obstruction in a wall space,...Ch. 4 - The recessed fluorescent luminaires installed in...Ch. 4 - Prob. 41RCh. 4 - What size overcurrent device protects the...Ch. 4 - May the 20-ampere small-appliance branch circuits...Ch. 4 - A 30-ampere branch circuit is installed for an...Ch. 4 - In many areas, metal framing members are being...Ch. 4 - Are set screwtype connectors permitted to be used...Ch. 4 - Most armored cable today has 90C conductors. What...Ch. 4 - If you saw two different types of SE cables, how...Ch. 4 - Circle the correct answer defining the type of...
Knowledge Booster
Similar questions
- If a grounding electrode conductor is connected at the first system disconnecting means or overcurrent device, the bonding jumper is sized the same as the ____. Select one: A. EQUIPMENT BONDING JUMPER B. POSITIVE CONDUCTOR C. SUPPLY-SIDE BONDING JUMPER D. NEUTRAL CONDUCTORarrow_forwardTo interconnect grounding electrode and form grounding electrode system, connect the________ to a busbar. A. Neutral Disconnect link and their grounding electrode conductor B. Grounding electrode conductor and their bond jumpers C. Bounding jumpers and their equipment grounding conductors D. Equipment grounding conductors and their neutral Disconnect linkarrow_forward- Loads, Service, and Overcurrent Protection 6.a. The general lighting load is based on a _______ per square foot basis.A. kilowattB. number of circuitsC. volt-ampereD. general illumination6.b. What's the primary disadvantage of using copper conductors?A. AvailabilityB. WeightC. CostD. Durabilityarrow_forward
- A(n) _________ is a reliable conductor used to ensure the required electrical conductivity between metal parts required to be electrically connected. a) Equipment bonding jumper b) Bonding conductor of jumper c) Main bonding jumper d) Equipment grounding conductorarrow_forwardThe course is power transmission system and the topic is Underground cables. Question : pressure cable are of two types. (i) oil filled cables. (ii) gas pressure cables What is the difference between two? Which one is good? Kindly explain the difference in detailarrow_forward4 Describe the various methods of laying underground cables. What are the relative advantages anddisadvantages of each method?arrow_forward
- The term "____" is defined in NEC® Article 100 as "connected to establish electrical continuity and conductivity." Select one: A. BENDED (BENDING) B. BONDED (BONDING) C. SHUNTED (SHUNTING) D. GROUNDED (GROUNDING)arrow_forwardEquipment Grounding 10. Which of the following statements about ground faults is true?A. They usually occur between any grounded circuit conductor and the equipment grounding conductor. B. They're often normal and typically intentional.C. They can't result from human error.D. They can happen if a conductive tool is dropped in an energized equipment's electrical enclosure.arrow_forwardWhen connecting a multiwire (3-wire) circuit to a single phase panel, one ungrounded conductor must be connected to the ____ phase and the other ungrounded conductor must be connected to the ____ phase. Select one: a. A, A b. B, B c. A, B d. doesn’t matterarrow_forward
- A? Conductor is defined in NEC 240.2 as a conductor, other than a service conductor, having overcurrent protection ahead of its point of supply that exceeds the value permitted for similar conductors that are not taps. A. Faulted b. Tap c. Magnetic d. Copper-likearrow_forwardwhat is grading of cables, explain proper in details with block diagramarrow_forward10. Main bonding jumpers are required to be made of _______ or other corrosion-resistant material.A. copperB. aluminumC. copper-clad aluminumarrow_forward