Electrical Wiring Residential
18th Edition
ISBN: 9781285170954
Author: Ray C. Mullin, Phil Simmons
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 4, Problem 39R
If, because of some obstruction in a wall space, it is impossible to keep a Type NM cable at least 1¼ in. (32 mm) from the edge of the stud, then it shall be protected by a metal plate at least in. thick.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Shackle type insulators are used for voltage
in the order of
... ..
Answer:
Q2/A- what are the main cases of insulator failures?
B-what are type testing of insulator?
Find the probability of exactly 2 flaws on 1mm of wire. Use 3 significant
figures *
For the case of the thin copper wire, suppose that
the number of flaws follows a Poisson distribution
With a mean of 2.3 flaws per mm. Find the
probability of exactly 2 flaws in 1 mm of wire.
Chapter 4 Solutions
Electrical Wiring Residential
Ch. 4 - The largest size solid conductor generally...Ch. 4 - What is the minimum branch-circuit wire size that...Ch. 4 - What exceptions, if any, are there to the answer...Ch. 4 - What determines the ampacity of a wire?Ch. 4 - What unit of measurement is used for the diameter...Ch. 4 - What unit of measurement is used for the...Ch. 4 - What is the voltage rating of the conductors in...Ch. 4 - Indicate the allowable ampacity of the following...Ch. 4 - Prob. 9RCh. 4 - What are the colors of the conductors in...
Ch. 4 - For nonmetallic-sheathed cable, may the...Ch. 4 - Prob. 12RCh. 4 - Under what condition may nonmetallic-sheathed...Ch. 4 - a. What is the maximum distance permitted between...Ch. 4 - Prob. 15RCh. 4 - Prob. 16RCh. 4 - Prob. 17RCh. 4 - Prob. 18RCh. 4 - Prob. 19RCh. 4 - Circle the correct answer to the following...Ch. 4 - When running Type NM cable through a bored hole in...Ch. 4 - Where is the main service-entrance panel located...Ch. 4 - Is it permitted to use flexible metal conduit over...Ch. 4 - Liquidtight flexible metal conduit may serve as a...Ch. 4 - It is permissible for an electrician to connect...Ch. 4 - Terminals of switches and receptacles marked...Ch. 4 - Wire connectors marked AL/CU are suitable for use...Ch. 4 - A wire connector bearing no marking or reference...Ch. 4 - When Type NM cable is run through a floor, it must...Ch. 4 - When nonmetallic-sheathed cables are bunched or...Ch. 4 - In diagrams A and B, nonmetallic-sheathed cable is...Ch. 4 - The marking on the outer jacket of a...Ch. 4 - A 120-volt branch circuit supplies a resistive...Ch. 4 - In problem 35, it is desired to keep the voltage...Ch. 4 - Prob. 37RCh. 4 - The allowable ampacity of a 4 AWG THHN from Table...Ch. 4 - If, because of some obstruction in a wall space,...Ch. 4 - The recessed fluorescent luminaires installed in...Ch. 4 - Prob. 41RCh. 4 - What size overcurrent device protects the...Ch. 4 - May the 20-ampere small-appliance branch circuits...Ch. 4 - A 30-ampere branch circuit is installed for an...Ch. 4 - In many areas, metal framing members are being...Ch. 4 - Are set screwtype connectors permitted to be used...Ch. 4 - Most armored cable today has 90C conductors. What...Ch. 4 - If you saw two different types of SE cables, how...Ch. 4 - Circle the correct answer defining the type of...
Additional Engineering Textbook Solutions
Find more solutions based on key concepts
What types of coolant are used in vehicles?
Automotive Technology: Principles, Diagnosis, And Service (6th Edition) (halderman Automotive Series)
Using your text editor, enter (that is, type in) the C++ program shown in Display 1.8. Be certain to type the f...
Problem Solving with C++ (10th Edition)
Comprehension Check 7-14
The power absorbed by a resistor can be given by P = I2R, where P is power in units of...
Thinking Like an Engineer: An Active Learning Approach (4th Edition)
How is the hydrodynamic entry length defined for flow in a pipe? Is the entry length longer in laminar or turbu...
Fluid Mechanics: Fundamentals and Applications
A byte is made up of eight a. CPUs b. addresses c. variables d. bits
Starting Out with Java: From Control Structures through Objects (7th Edition) (What's New in Computer Science)
Which of the following are illegal variable names in Python, and why? x 99bottles july2009 theSalesFigureForFis...
Starting Out with Python (4th Edition)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- When Type NM cable is run through a floor, it must be protected by at least ______ in. (_____ mm) of ________arrow_forwardWhen running Type NM cable through a bored hole in a stud, the nearest edge of the bored hole shall not be less than ________ in. from the face of the stud unless the cable is protected by a 116 in. (1.6 mm) metal steel plate(s).arrow_forward3. A 2-wire d.c. distributor AB 500 metres long is fed from point .4 and is loaded as under: Distance from feeding point.4 (in metres) Load (amperes) If the specific resistance of copper is 1-7x 10 Sm what must be the cross-section of each wire in order that the voltage drop in the dismbutor shall not exceed 10 volts ? 100 300 400 500 20 40 40 50 [1 734 cm]arrow_forward
- 2arrow_forward3. A 2-wire d.c. distributor AB 500 metres long is fed from point A and is loaded as under : Distance from feeding point A (in metres) 100 300 400 500 Load (amperes) If the specific resistance of copper is 1-7 x 10 Qm, what must be the cross-section of each wire in order that the voltage drop in the distributor shall not exceed 10 volts ? 20 40 40 50 [1-734 cm]arrow_forwardI Need the answer as fast as possible pleasearrow_forward
- State the main constituent elements of electrical cables, as well as the materials from which they may be made. Describe the following designations: H05VV-U 1G4 mm? and LSXAV 3x16 mm?.arrow_forwardHow IGBT is classified based on its layer of construction? Compare the characteristics of the device (Minimum Four Points) with cross sectional views of the type.arrow_forwardWhat is the advantage of using erasing shieldarrow_forward
- What unit of measurement is used for fhe diameter of fhe wiresarrow_forwardA cylindrical 00 AWG copper wire is coated with NEMA class B insulation. The normal operating temperature of the wire is 40°C. What is the maximum current the wire can carry for 1 second without exceeding the NEMA temperature rating?arrow_forwardA semiconductor is a material that has _____ energy band gap. a)no b)wide c)narrow d)nucleararrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTElectricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
Types of House Wiring - Types of Electrical Wiring - Electrical Wiring; Author: Learning Engineering;https://www.youtube.com/watch?v=A5P-buWX-dA;License: Standard Youtube License