The Defibrillator A defibrillator is designed to pass a large current through a patient’s torso in order to stop dangerous heart rhythms. Its key part is a capacitor that is charged to a high voltage. The patient’s torso plays the role of a resistor in an RC circuit. When a switch is closed, the capacitor discharges through the patient’s torso. A jolt from a defibrillator is intended to be intense and rapid; the maximum current is very large, so the capacitor discharges quickly. This rapid pulse depolarizes the heart, stopping all electrical activity. This allows the heart’s internal nerve circuitry to reestablish a healthy rhythm. A typical defibrillator has a 32 μ F capacitor charged to 5000 V. The electrodes connected to the patient are coated with a conducting gel that reduces the resistance of the skin to where the effective resistance of the patient’s torso is 100 Ω. If a patient receives a series of jolts, the resistance of the torso may increase. How does such a change affect the initial current and the time constant of subsequent jolts? A. The initial current and the time constant both increase. B. The initial current decreases, the time constant increases. C. The initial current increases, the time constant decreases. D. The initial current and the time constant both decrease.
The Defibrillator A defibrillator is designed to pass a large current through a patient’s torso in order to stop dangerous heart rhythms. Its key part is a capacitor that is charged to a high voltage. The patient’s torso plays the role of a resistor in an RC circuit. When a switch is closed, the capacitor discharges through the patient’s torso. A jolt from a defibrillator is intended to be intense and rapid; the maximum current is very large, so the capacitor discharges quickly. This rapid pulse depolarizes the heart, stopping all electrical activity. This allows the heart’s internal nerve circuitry to reestablish a healthy rhythm. A typical defibrillator has a 32 μ F capacitor charged to 5000 V. The electrodes connected to the patient are coated with a conducting gel that reduces the resistance of the skin to where the effective resistance of the patient’s torso is 100 Ω. If a patient receives a series of jolts, the resistance of the torso may increase. How does such a change affect the initial current and the time constant of subsequent jolts? A. The initial current and the time constant both increase. B. The initial current decreases, the time constant increases. C. The initial current increases, the time constant decreases. D. The initial current and the time constant both decrease.
A defibrillator is designed to pass a large current through a patient’s torso in order to stop dangerous heart rhythms. Its key part is a capacitor that is charged to a high voltage. The patient’s torso plays the role of a resistor in an RC circuit. When a switch is closed, the capacitor discharges through the patient’s torso. A jolt from a defibrillator is intended to be intense and rapid; the maximum current is very large, so the capacitor discharges quickly. This rapid pulse depolarizes the heart, stopping all electrical activity. This allows the heart’s internal nerve circuitry to reestablish a healthy rhythm.
A typical defibrillator has a 32 μF capacitor charged to 5000 V. The electrodes connected to the patient are coated with a conducting gel that reduces the resistance of the skin to where the effective resistance of the patient’s torso is 100 Ω.
If a patient receives a series of jolts, the resistance of the torso may increase. How does such a change affect the initial current and the time constant of subsequent jolts?
A. The initial current and the time constant both increase.
B. The initial current decreases, the time constant increases.
C. The initial current increases, the time constant decreases.
D. The initial current and the time constant both decrease.
While cruising down University Boulevard you are stopped by a cop who states that you ran a red traffic light. Because you don't
want to pay the stiff fine, you are attempting a physics defense. You claim that due to the relativistic Doppler effect, the red color of
the light λ=616 nm appeared green '=531 nm to you. The cop makes a quick calculation of his own and rejects your defense.
How fast, in terms of your speed u divided by the speed of light in vacuum c, would you have to drive to justify your claim? Note
that the speed u is taken to be a positive quantity.
U 4.0
C
220 V is supplied to 800 primary turns of an autotransformer. What will the outputvoltage be across 200 secondary turns?
2. A filament transformer has a turns ratio of 1:20. What current must be supplied to theprimary windings if 5 A is required by the filament?
3. The filament transformer in the previous question is supplied with 150 V to theprimary side. What is the secondary voltage?
4. 440 V is supplied to 1000 primary turns of an autotransformer. If the desired outputvoltage is 100 V how many secondary turns must be tapped?
Chapter 23 Solutions
College Physics: A Strategic Approach Technology Update, Books a la Carte Plus Mastering Physics with Pearson eText -- Access Card Package (3rd Edition)
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, physics and related others by exploring similar questions and additional content below.
How To Solve Any Resistors In Series and Parallel Combination Circuit Problems in Physics; Author: The Organic Chemistry Tutor;https://www.youtube.com/watch?v=eFlJy0cPbsY;License: Standard YouTube License, CC-BY