Chapter 22.1, Problem 4R
a.
To determine
Mention the number of wires required to connect the wall switches and the heat/vent/light loads.
b.
To determine
Mention the size of wires required for the heat/vent/light loads.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
QUESTION 9
When a ground wire is connected to an interior gas piping system and the underground portion of the gas pipe into the building is plastic, which of the following is (or are) true?
a
A.This would be approved by code as the gas pipe is only being bonded to the electrical system.
b
B.This installation would be approved by code, as the gas pipe is not a grounding electrode.
c
C.Both A and B
d
D.Neither A nor B
Grounding Lighting Fixtures. There are specific requirements for grounding lighting fixtures. How must they be grounded and with what size conductors? Be sure and cite the code in your answers.
A device used in kitchen serving hotels dining rooms club houses and restaurants is__________.
a.) Grease basin b.) Yard basin c.) Garage basin d.) Oil catch basin
Chapter 22 Solutions
ELECTRICAL WIRING:RESIDENTAL-6 PLANS
Ch. 22.1 - Prob. 1RCh. 22.1 - Prob. 2RCh. 22.1 - Prob. 3RCh. 22.1 - Prob. 4RCh. 22.1 - Prob. 5RCh. 22.1 - Prob. 6RCh. 22.1 - Prob. 7RCh. 22.1 - Prob. 8RCh. 22.1 - Prob. 9RCh. 22.1 - Prob. 10R
Ch. 22.1 - Prob. 11RCh. 22.1 - Prob. 12RCh. 22.2 - Prob. 1RCh. 22.2 - Prob. 2RCh. 22.2 - Prob. 3RCh. 22.2 - Prob. 4RCh. 22.2 - Prob. 5RCh. 22.2 - Prob. 6RCh. 22.2 - Prob. 7RCh. 22.2 - Prob. 8RCh. 22.2 - Prob. 9RCh. 22.2 - Prob. 10RCh. 22.2 - Prob. 11RCh. 22.2 - Prob. 12RCh. 22.3 - Prob. 1RCh. 22.3 - Which of the following statements Meets Code?...Ch. 22.3 - Prob. 3RCh. 22.3 - Prob. 4RCh. 22.3 - Prob. 5RCh. 22.3 - Prob. 6RCh. 22.3 - Prob. 7RCh. 22.3 - Prob. 8R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Fill in the blanks. One of electrical wiring design procedure is that circuit all ____________ and __________ to the appropriate panels and prepare the panel schedule.arrow_forward___________ is an Area on a device characteristic where the ratio between applied voltage and resulting current is constant.arrow_forwardIf a recessed luminary without an integral junction boxes installed what extra wiring must be providedarrow_forward
- 1. A14/2 type copper used for a general lighting branch circuit. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 2.Three 8 AWG copper conductors with THHN insulation Installed in garage in electrical metallic tubing (EMT). The ambient temperature in the garage can reach as high as 110'F. All termination points for this circuit are rated 60'C. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 3.Four 4 AWG copper conductor with THWN insulation imstalled in EMT in a basement. All termination points are rated at 60'C. Ampacity:______________ Maximum Fuse or Circuit Breakers Sizes:________________ 4. An 8/3 Type UF copper cable installed underground from a house to a detached garage to feed a 120/240-volt subpanel. All termination points are rated at 60'C.…arrow_forwardFour electricians are discussing wiring under raised floors in information technology equipment rooms. Electrician A says that wiring under the raised floor requires fire-resistant walls, floors, and ceilings between other occupancies. Electrician B says that wiring under the raised floor requires fire resistant halfway up the walls and floors between other occupancies. Electrician C says that the room must employ a disconnecting means that removes half of the power to all equipment in the room. Electrician D says that a disconnecting means isn't necessary for the room. Which of the following statements is correct? A. Electrician B is correct. B. Electrician D is correct. C. Electrician A is correct. D. Electrician C is correct.arrow_forward2. Imagine that you're asked to install an auxiliary grounding electrode at the base of a lighting pole in aparking lot. This auxiliary grounding electrode will be connected to theA. lighting pole's electrical service equipment grounding conductor.B. electrical service's grounding electrode conductor.C. next lighting pole's auxiliary grounding electrode.D. lighting pole's neutral conductor.arrow_forward
- 1.1 PV modules can be wired together in an array using ______ connections to increase voltage. a. Terminating b. Series c. Parallel d. AC 1.2 A PV module, also called a solar panel, is comprised of individual photovoltaic _______ wired and mounted together as an integrated unit. a. Capsules b. Compartments c. Chips d. Cells 1.3 A __________ system uses a storage system that stores the generated electricity so it can provide during times when the system’s panels are not receiving solar energy. a. Direct coupled b. Self regulating c. Charge controlled d. Indirectly connected 1. 4 __________ energy may have the potential to supply all of the world's energy needs, but at this time, it provides a very small percentage. a. Coal b. Natural Gas c. Diesel d. Solararrow_forwardWhich of the following statements about equipment grounding conductors (EGCs) is true?A. The National Electrical Code permits the EGC to also perform as a grounding electrode conductor.B. More than one EGC must be used if multiple circuits are installed in a single raceway, cable, or cable tray.C. No current should be present in the EGC during normal operation.D. EGCs are required to be decreased in size to address voltage drop.arrow_forward6.a. A run of conduit that will carry several conductors is installed inside a wall. The wall is later finished sothat the run of conduit is no longer visible. This is an example of a(n)A. load.B. device.C. NEC violation.D. concealed raceway.6.b. Since the voltages across each branch circuit in a residence are the same, these circuits areA. connected in series.B. connected in parallel.C. controlled circuit configurations.D. complex circuit configurations.arrow_forward
- Electrical Engineering Give correct answer UPSs measured in ____________ and ______________. __________________ are what your system uses and ____________________________ are what UPS can deliver in a perfect world.arrow_forwardThe circuit breaker cubicles illustrated in your reading material each contain____circuit breakers. A. Two B. Three C. Four D. Sixarrow_forward6.a. Extreme _______ may cause some nonmetallic conduits to become brittle and therefore moresusceptible to damage from physical contact.A. coldB. corrosionC. voltageD. heat6.b. Snap switches are permitted to be grouped or ganged in an enclosure provided the voltage between theadjacent snap switches does not exceed ___ V.A. 400B. 300C. 200D. 100arrow_forward
arrow_back_ios
SEE MORE QUESTIONS