Chapter 22.1, Problem 3R
To determine
Explain the reason for the usage of the given equipment for the switch assembly of heat/vent/light loads.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
If a recessed luminary without an integral junction boxes installed what extra wiring must be provided
A device used in kitchen serving hotels dining rooms club houses and restaurants is__________.
a.) Grease basin b.) Yard basin c.) Garage basin d.) Oil catch basin
In order to wire a post light, a homeowner purchased some single-conductor cable that was marked as suitable for direct burial in the ground. A separate equipment grounding conductor to the post light was not carried. Instead, the bottom of the metal post, buried 2 ft (0.6 m) into the ground, was used as a ground for the post light. The inspector “red tagged” (turned down) the installation. Who is right—the homeowner or the electrical inspector?
Explain.
Chapter 22 Solutions
ELECTRICAL WIRING:RESIDENTAL-6 PLANS
Ch. 22.1 - Prob. 1RCh. 22.1 - Prob. 2RCh. 22.1 - Prob. 3RCh. 22.1 - Prob. 4RCh. 22.1 - Prob. 5RCh. 22.1 - Prob. 6RCh. 22.1 - Prob. 7RCh. 22.1 - Prob. 8RCh. 22.1 - Prob. 9RCh. 22.1 - Prob. 10R
Ch. 22.1 - Prob. 11RCh. 22.1 - Prob. 12RCh. 22.2 - Prob. 1RCh. 22.2 - Prob. 2RCh. 22.2 - Prob. 3RCh. 22.2 - Prob. 4RCh. 22.2 - Prob. 5RCh. 22.2 - Prob. 6RCh. 22.2 - Prob. 7RCh. 22.2 - Prob. 8RCh. 22.2 - Prob. 9RCh. 22.2 - Prob. 10RCh. 22.2 - Prob. 11RCh. 22.2 - Prob. 12RCh. 22.3 - Prob. 1RCh. 22.3 - Which of the following statements Meets Code?...Ch. 22.3 - Prob. 3RCh. 22.3 - Prob. 4RCh. 22.3 - Prob. 5RCh. 22.3 - Prob. 6RCh. 22.3 - Prob. 7RCh. 22.3 - Prob. 8R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- QUESTION 9 When a ground wire is connected to an interior gas piping system and the underground portion of the gas pipe into the building is plastic, which of the following is (or are) true? a A.This would be approved by code as the gas pipe is only being bonded to the electrical system. b B.This installation would be approved by code, as the gas pipe is not a grounding electrode. c C.Both A and B d D.Neither A nor Barrow_forwardA means shall be provided in each metal box over 100 cubic inches for the connection of an equipment grounding conductor. The means shall be permitted to be ______. a tapped hole the cover screw III. a screw used to mount the box (a.) I only (c.) I & II only (b.) II only (d.) I, II or IIIarrow_forwardAn open in one of the heated rear window grid elements can be repaired by ______. a. pealing the heat grid off the glass with a heat gun and installing a new grid element b. applying a thin strip of a repair compound to the damaged area c. bridging the damaged area with rosin core solder d. replacing the window glassarrow_forward
- Answer the following: A) Type of clipper circuit per level of clipping. 1. ___________ 2. ___________ 3. ___________ B) Type of clipper circuit per non-linear devices used. 1. ___________ 2. ___________ C) Other term for clipper circuit. 1. ___________ 2. ___________ 3. ___________arrow_forwardPlease provide Handwritten answer Question: NEC Reference Answer __________ __________ _____ is a jack or terminal that serves as the collection point for redundant grounding of electric appliances serving a patient care vicinity or for grounding other items in order to eliminate electromagnetic interference problems.Question: NEC Reference Answer __________ __________ _____ is a jack or terminal that serves as the collection point for redundant grounding of electric appliances serving a patient care vicinity or for grounding other items in order to eliminate electromagnetic interference problems.arrow_forward13. If an equipment bonding jumper is run external to a raceway, it must be less than _______ feet.A. 6B. 2C. 4D. 5arrow_forward
- When used as service equipment, a panelboard (load center) must be ______________________ that is suitable for use as service equipment, 230.66. If the panelboard (load center) contains the main service disconnect, it must be clearly marked ____________________________________, 230.70(B).arrow_forwardf.1. Since the footing or foundation is generally part of the grounding electrode system, the _______electrode is one of the first electrodes installed.A. metal water pipeB. plateC. concrete-encasedD. ground ringf.2. When you're connecting the grounding electrode conductor to a metal water pipe as it enters a building,the connection must be made within _______ feet of the pipe's entrance to the building.A. 10B. 5C. 15D. 7f.3. Which National Electrical Code table is used for sizing grounding electrode conductors?A. Table 250.102(C)(1)B. Table 250.66C. Table 250.122D. Table 250.118(6)(a)arrow_forwardFollow the procedures in troubleshooting the defects and faults of an electric fan by filling in the missing steps.Doesn't rotate 1.___________ 2.____________ Check for Open AC cord or wiring3. ___________4.___________ Defective switch/electronic system control 5. _____________Defective module (system control).arrow_forward
- To answer the question, type your answers in RED or paste the image of your handwriting solution Given the circuit #1 presented above, answer the following questions: Determine the value of the VD (voltage forward of the LED) for the LEDs RED, VDRED, GREEN, VDGREEN and BLUE, VDBLUE, when the current through the LEDs is 10mA, VDRED = ____________ ; VDGREEN = ____________ ; VDBLUE = ____________ Is the LED in Circuit #1, connected in the way that will be lighting up or not – Justify your answer Type your answer here Calculate the value of the resistance Rled in Circuit #1, to ensure that a RED LED will have a current of 10 mA Type your answer here or paste the image of your handwriting solution here Calculate the value of the resistance Rled in Circuit #1, to ensure that a GREEN LED will have a current of 10 mA Type your answer here or paste the image of your handwriting solution here Calculate the value of the resistance Rled in Circuit #1, to ensure that…arrow_forward1)The NEC Style Manual indicates that if a term in the NEC appears in more than two articles, it qualifies for a definition in which of the following. a) The articles where the term appears b) Article 90 c) Article 100 d) Table of Contents 2)Definitions of terms related to grounding and bonding and used only in Article 250 are located in ________.a) Article 100 b) Article 200 c) Chapter 9 d) Section 250.2 3)As a general rule, when installing ground rod electrodes, two must be installed always unless a single ground rod provides not more than 25 ohms’ resistance to ground. a) True b) Falsearrow_forwardThe minimum working space width in front of service equipment installed in a house must be ______ inches wide or the width of the equipment, whichever is greater. The minimum amount of clear space in front of service equipment must be at least ______ feet. This space must be maintained to a height from the floor of ______ feet. Name the NEC® section that covers these requirementsarrow_forward