Question
Chapter 22.3, Problem 8R
To determine
Choose a suitable option from the given options.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
QUESTION 3
We are running 3 wires and a ground in a RMC to a control panel with a 60 amp circuit breaker disconnect in the control panel. The conduit is run along the ceiling where the ambient air temperature is 100 degrees. The control panel feeds our secondary cooling pump. What size are the ungrounded conductors? All conductors have typeTHHN insulation.
8. Connect the Electronic VOM, set to the ammeter function on the 15mAdc range,between points A and D.9. Close switch S1. Measure current IAB.
IAB = 19.5 mAdc
10. Measure current IAD flowing through resistor R1.
IAD = 14.8 mAdcAre currents IAB and IAD entering or leaving point A? __________
Is the sum of currents IAB and IAD equal to total current IT? __________Is the current IAB entering or leaving a junction point B? __________
A feeder is installed to feed a sub panel. The feeder starts at a 400-amp breaker, utilizing (2) parallel
4/0 THWN-2 copper conductors in the same conduit. What size is the copper equipment grounding
conductor required to be?
OA. Parallel (2) #1/0
B. #3
OC. #1/0
OD. Parallel (2) #4/0
Chapter 22 Solutions
ELECTRICAL WIRING:RESIDENTAL-6 PLANS
Ch. 22.1 - Prob. 1RCh. 22.1 - Prob. 2RCh. 22.1 - Prob. 3RCh. 22.1 - Prob. 4RCh. 22.1 - Prob. 5RCh. 22.1 - Prob. 6RCh. 22.1 - Prob. 7RCh. 22.1 - Prob. 8RCh. 22.1 - Prob. 9RCh. 22.1 - Prob. 10R
Ch. 22.1 - Prob. 11RCh. 22.1 - Prob. 12RCh. 22.2 - Prob. 1RCh. 22.2 - Prob. 2RCh. 22.2 - Prob. 3RCh. 22.2 - Prob. 4RCh. 22.2 - Prob. 5RCh. 22.2 - Prob. 6RCh. 22.2 - Prob. 7RCh. 22.2 - Prob. 8RCh. 22.2 - Prob. 9RCh. 22.2 - Prob. 10RCh. 22.2 - Prob. 11RCh. 22.2 - Prob. 12RCh. 22.3 - Prob. 1RCh. 22.3 - Which of the following statements Meets Code?...Ch. 22.3 - Prob. 3RCh. 22.3 - Prob. 4RCh. 22.3 - Prob. 5RCh. 22.3 - Prob. 6RCh. 22.3 - Prob. 7RCh. 22.3 - Prob. 8R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- 1.1 PV modules can be wired together in an array using ______ connections to increase voltage. a. Terminating b. Series c. Parallel d. AC 1.2 A PV module, also called a solar panel, is comprised of individual photovoltaic _______ wired and mounted together as an integrated unit. a. Capsules b. Compartments c. Chips d. Cells 1.3 A __________ system uses a storage system that stores the generated electricity so it can provide during times when the system’s panels are not receiving solar energy. a. Direct coupled b. Self regulating c. Charge controlled d. Indirectly connected 1. 4 __________ energy may have the potential to supply all of the world's energy needs, but at this time, it provides a very small percentage. a. Coal b. Natural Gas c. Diesel d. Solararrow_forwardAn electrician installs five 3 AWG THWN copper current-carrying conductors in a raceway located in a garage. The garage area is subject to an ambient temperature of 100°F. All terminations are rated at 75°C.Ampacity: __________ Maximum Fuse or Circuit Breaker Size: __________.(NO CHAT GPT, ONLY NEAT HAND WRITTEN SOLUTION PLEASE.)arrow_forwardQuestion 6 B Thevenin’s Theorem RL what VTH RTH Full explain this question very fast solution sent me step by step Not:- Text typing work only and Don't ignore any part all part work uarrow_forward
- If a recessed luminary without an integral junction boxes installed what extra wiring must be providedarrow_forwardAssignment on Threaded jointsDue date:__________________ ___________________ ________________ Surname Given names IDA power line tower is erected to support a high-voltage power line (see figure below),which includes six phase conductors and three Earth shield wires. The tower isfabricated as a steel structure resting on four square supporting feet bolted to aconcrete foundation with four Anker bolts at each support (see figure below). Theresultant tension force FT from cables on each side of the tower is applied at point m,and can be at 60o to the horizontal plane (sagging downwards) if the tower is installedon a plane or at 30o to the horizontal plane pointed upwards if the tower is installed on ahilly landscape. The gusty wind load, which could be represented with a resultant forceof Fw is applied at the geometric centre of the tower n in any direction in the horizontalplane (see figure below) and tends to shift the tower sideways and topple it. In the caseof an accident when all…arrow_forwardThe recessed fluorescent luminaires installed in the ceiling of the recreation room of this residence are connected with trade size flexible metal conduit. These flexible connections are commonly referred to as fixture whips. Does the flexible metal conduit provide adequate grounding for the luminaires, or must a separate equipment grounding conductor be installed? ________________arrow_forward
- a. The Code requires a minimum of two small-appliance circuits in a kitchen. Is it permitted to connect a receptacle in a dining room to one of the kitchen small-appliance circuits? _______________ What Code section applies to this situation? _______________ b. Are outdoor weatherproof receptacles permitted to be connected to a 20-ampere small-appliance circuit? _______________ c. Receptacles located above the countertops in the kitchen must be supplied by at least _______________ 20-ampere small-appliance circuits.arrow_forwardanswer number 4 only.arrow_forwardTo testing installation of grounds, the usual procedure is to connect one lead of the megohmmeter to one of the conductors, then the other lead is___. A, connected to another conductor b, connected to the conduit or raceway c. Connected to a special grounding electrode on the megohmmeter d. Left unconnectedarrow_forward
- Two 12-2 AWG and two 14-2 AWG nonmetallic-sheathed cables enter a box. Each cable has an equipment grounding conductor. The 12 AWG conductors are connected to a receptacle. Two of the 14 AWG conductors are connected to a toggle switch. The other two 14 AWG conductors are spliced together because they serve as a switch loop. The box contains two cable clamps. Calculate the minimum cubic-inch volume required for the box.arrow_forwardIn order to wire a post light, a homeowner purchased some single-conductor cable that was marked as suitable for direct burial in the ground. A separate equipment grounding conductor to the post light was not carried. Instead, the bottom of the metal post, buried 2 ft (0.6 m) into the ground, was used as a ground for the post light. The inspector “red tagged” (turned down) the installation. Who is right—the homeowner or the electrical inspector? Explain.arrow_forwardQUESTION 5 A duplex receptacle is installed on a 4-inch square raised metal cover and mounted on a 4-inch square metal box.If the grounding terminal of the receptacle is connected to the grounded metal box, which of the following requirements would also apply to the installation of the duplex receptacle? a It must be secured by at least two screws. b The single 6/32 screw holding it in the cover must be tight. c It must be secured directly to the 4 inch square box. d It is not permitted to be installed in raised covers.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS