Principles of Instrumental Analysis
7th Edition
ISBN: 9781305577213
Author: Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 20, Problem 20.18QAP
Interpretation Introduction
Interpretation:
The ions which results in the four peaks having larger mass-to-charge ratios than the M+ peak in given should be identified.
Concept introduction:
Mass spectrometry is a powerful analytical technique which is used to elucidate structure of compounds, quantify materials, identify unknown compounds etc. In mass spectrophotometer the molecule is ionized by giving it a positive charge by removing an electron or by adding a proton. The molecule may break into several positively charged fragments according to the ionization method used. Then in a mass analyzer these cationic molecular fragments are separated based on their mass and detected by the detector. Only positively charged molecular fragments are detected by the detector.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
The intensities of peaks at 69 m/z, 70 m/z, and 71 m/z are 1.2, 31.2, and 1.7, respectively. How
many carbons does the compound have?
100
MS-NU-1334
80
40
20
10
15
25
30
35
40
45
50
55
60
65
70
m/z
Relative Intensity
20
A student prepared several solutions of Molecule Bright, each at a different concentration. The absorbance of each solution was measured at 405 nm with a path length of 0.730 cm. The student then plotted the absorbance of each sample vs. its concentration (in mM), and found a best-fit line of y = 3.726x + 0.828. Calculate the molar absorptivity of the Molecule Bright (in M-1 cm-1).
Assign the peaks and identify what the structure is.
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Similar questions
- 2 What can be described if a sample analyzed by AAS shows the following results:arrow_forwardIn an ideal mass spectrum of a compound, the following data (intensity) is given: M* = 80% %3D M +1 = 8.8% How many carbons are expected to be present in the parent molecule? 0 7 0 8 O 10arrow_forwardShow COMPLETE solutions. Round-off FINAL answer to the 4th decimal The absorption coefficient of Sample Z at 340 nm is 600 Mol-1cm-1. What absorbance will be observed when light at 340 nm passes through a 1 cm cuvette containing 0.001M Sample zk A solution put in a 1.5 cm container transmits 55% incident light. Calculate the concentration of the solution, given that ɛ = 6x10-3 Mol-1cm-1. A solution shows a transmittance of 39.72%, when taken in a container measuring 3.5 cm thickness. Calculate its concentration, if the molar absorption coefficient is 3x10-2 Mol-1cm- 1.arrow_forward
- What does the "(<1%)" in the mass spectrum mean?arrow_forward4. what are the major peaks of the spectrum and what chemical is madearrow_forwardSuppose you are analyzing mercury ions (Hg2+) in drinking water samples with atomic absorption spectroscopy. If the Hg2+ signal varies by a matrix of sample, which of the following should be used as a standard for calibration? Either cations or anions can be used if they are different from Hg2+, 0 H20 Any anions can be used if they are different from Hg2+ Any cations can be used if they are different from Hg?". Hg2+arrow_forward
- Fluorometry is more selective and more sensitive than absorption spectrometry.Tell what is meant by selectivity and sensitivity.arrow_forwardDetermine the isotopic peak scheme for [ReCl]+ fragment in the mass spectrum? 185Re: %37 ; 187Re: %63; 35Cl: %76; 37Cl: %24arrow_forwardWhat is peak multiplicity and how does multiplicity arise?arrow_forward
- The molecular weight for His is 155.1546. At what mass would you observe the positive ion peak for His in the protonation state with a +2 charge in an ESI-mass spectrum?arrow_forwardA student prepared several solutions of an unknown molecule, each at a different concentration. The absorbance of each solution was measured at 630 nm with a path length of 0.760 cm. The student then plotted the absorbance of each sample vs. its concentration (in uM), and found a best-fit line of y = 0.00626x + 0.00732. Calculate the molar absorptivity of the unknown molecule (in M-1 cm-1).arrow_forward1arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage LearningMacroscale and Microscale Organic ExperimentsChemistryISBN:9781305577190Author:Kenneth L. Williamson, Katherine M. MastersPublisher:Brooks Cole
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning
Macroscale and Microscale Organic Experiments
Chemistry
ISBN:9781305577190
Author:Kenneth L. Williamson, Katherine M. Masters
Publisher:Brooks Cole