- a. When more than three current-carrying conductors are installed in one raceway, their allowable ampacities must be reduced according to NEC __________.
- b. The following is a project. We need four 15-ampere branch circuits. We will use two 3-wire multiwire branch circuits and 14 AWG THHN conductors. We will install the conductors in EMT. The room temperature will not exceed 86°F (30°C). The connected load is nonmotor and is noncontinuous.
- 1. What is the minimum trade size EMT? __________
- 2. What is the ampacity of the conductors before derating? __________
- 3. What is the ampacity of the conductors after derating? __________
- 4. What is the maximum overcurrent protection permitted for these conductors? __________
- c. Let’s increase the conductor size to 12 AWG THHN for the same installation to see what happens.
- 1. What is the minimum trade size EMT? __________
- 2. What is the ampacity of the conductors before derating? __________
- 3. What is the ampacity of the conductors after derating? __________
- 4. What is the maximum overcurrent protection permitted for these conductors? __________
- d. It (is) (is not) necessary to count equipment grounding conductors, a neutral conductor that carries the unbalanced current from other conductors of the same circuit, and/or “travelers” when installing 3-way and 4-way switches for the purposes of derating the ampacity of these conductors. Circle the correct answer. Explain.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
h.1. In an alternating-current system, the maximum size for a copper grounding electrode conductor isA. 250 kcmil.B. 3/0.C. 500 kcmil.D. 4/0.
h.2. The figure shows a fault condition in an ungrounded electrical system. Which of the following will occurbecause of the fault in this system?A. Only the overcurrent protector at Point A will trip open.B. The ground fault will heavily damage the service.C. Nothing will happen until a second ground fault occurs.D. The overcurrent protection will trip, shutting off all the line side power.
i need the answer quickly
Four No. 12 and four No. 10 conductors are to be installed in a EMT conduit 600 V jacketed. What size EMT conduit is required if a. The conductors are Type T90 Nylon? b. The conductors are Type RW90?
Chapter 18 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 18 - a. What circuit supplies the workshop lighting?...Ch. 18 - Prob. 2RCh. 18 - a. How is EMT fastened to masonry? _______________...Ch. 18 - What type of luminaires are installed on the...Ch. 18 - Prob. 5RCh. 18 - To what circuit are the smoke detectors connected?...Ch. 18 - Is it a Code requirement to connect smoke...Ch. 18 - Prob. 8RCh. 18 - Prob. 9RCh. 18 - Prob. 10R
Ch. 18 - Adjustment factors for conductor ampacities must...Ch. 18 - Prob. 12RCh. 18 - Prob. 13RCh. 18 - Calculate the total current draw of Circuit A17 if...Ch. 18 - Prob. 15RCh. 18 - A conduit body may contain splices if marked with...Ch. 18 - What size box would you use where Circuit A17...Ch. 18 - List the proper trade size of electrical metallic...Ch. 18 - According to the Code, what trade size EMT is...Ch. 18 - a. When more than three current-carrying...Ch. 18 - Prob. 21RCh. 18 - For laundry equipment in basements, what sort of...Ch. 18 - Prob. 23RCh. 18 - A Type NM cable carries a branch circuit to the...Ch. 18 - Prob. 25RCh. 18 - The following is a layout of the lighting circuits...Ch. 18 - Prob. 27RCh. 18 - Prob. 28R
Additional Engineering Textbook Solutions
Find more solutions based on key concepts
17–1C A high-speed aircraft is cruising in still air. How does the temperature of air at the nose of the aircra...
Thermodynamics: An Engineering Approach
The following C++ program will not compile because the lines have been mixed up. cout Success\n; cout Success...
Starting Out with C++ from Control Structures to Objects (9th Edition)
What types of coolant are used in vehicles?
Automotive Technology: Principles, Diagnosis, And Service (6th Edition) (halderman Automotive Series)
A byte is made up of eight a. CPUs b. addresses c. variables d. bits
Starting Out with Java: From Control Structures through Objects (7th Edition) (What's New in Computer Science)
What is an uninitialized variable?
Starting Out with Programming Logic and Design (5th Edition) (What's New in Computer Science)
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Seven 8 AWG copper conductors are run in conduit. Each conductor has type THHN insulation. The conduit is located in an area with an ambient temperature of 138oF. What is the ampacity of each conductors?arrow_forward10. Main bonding jumpers are required to be made of _______ or other corrosion-resistant material.A. copperB. aluminumC. copper-clad aluminumarrow_forwardWhat is the voltage rating of the conductors in Type NMC cable? _______________arrow_forward
- Define service-drop conductors.arrow_forwardDefine an equipment grounding conductor.arrow_forwardc.1. Which of the following is one of the three essential functions of an equipment grounding conductor?A. Provide an arc-fault current pathB. Establish groundingC. Establish bondingD. Ensure the system is groundedc.2. What's another name for the three-point method of Earth resistance testing?A. Fall-of-potentialB. Line surgeC. Spatial shieldingD. Leakage current c.3. If the National Electrical Code provides a requirement to ground equipment, it generally implies thatthere will be a direct connection to the Earth of a connection through a/anA. grounding electrode conductor.B. equipment grounding conductor.C. equipotential bonding conductor.D. bonding conductor.arrow_forward
- A circuit breaker is rated as 132 KV, 4000 MVA. What will be the Asymmetrical breaking current capacity if DC component is assumed to be 70% ?arrow_forward5arrow_forward8.a. A _______ conductor does not carry current during normal operation.A. neutralB. groundingC. phaseD. grounded8.b. "The complete path of an electric current" describes an electric(al)A. fault.B. circuit.C. source.D. component.arrow_forward
- Twenty-two 14 AWG copper conductors are run in conduit. Each conductor has type THHN insulation. the conduit is located in an area with an ambient temperature of 101oF. What is the ampacity of each conductors?arrow_forwardpure dc will have ____ ripplearrow_forwardA? Conductor is defined in NEC 240.2 as a conductor, other than a service conductor, having overcurrent protection ahead of its point of supply that exceeds the value permitted for similar conductors that are not taps. A. Faulted b. Tap c. Magnetic d. Copper-likearrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENTPower System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage LearningElectricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
FMPR-103 pt1 l Power Systems Protection v1; Author: L&D for Protection and Control;https://www.youtube.com/watch?v=ELWncjsh5uE;License: Standard Youtube License