Textbook Question
Chapter 18, Problem 24R
A Type NM cable carries a branch circuit to the outside of a building, where it terminates in a metal weatherproof junction box. From this box, a short length of EMT is installed upward to another metal weatherproof junction box on which is attached a cluster of outdoor floodlights. The first box is located approximately 24 in. (600 mm) above the ground. To “Meet Code,” do the metal boxes and metal raceway have to be grounded? Yes _______________ No _______________ NEC _______________.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
3.a. When feeders or branch circuits are installed to supply a separate building or structure, a/an _______must also be installed.A. snap switchB. junction boxC. equipment grounding conductorD. supply conductor3.b. How many system bonding jumpers normally are there for a separately derived system that's grounded?A. TwoB. OneC. ZeroD. Three
L1. Boxes are classified by type, construction, andA. installation location.B. luminaire support capability.C. number of knockouts.D. power rating
L2. Which of the following devices must be placed at each end of an armored cable to prevent damage tothe conductors?A. An insulating sliderB. An insertion couplingC. An antishort bushingD. A metal loop fitting
L3. Which of the following is the maximum cross-sectional conductor fill area for underfloor raceways?A. 50%B. 60%C. 40%D. 30%
Equipment Grounding
10. Which of the following statements about ground faults is true?A. They usually occur between any grounded circuit conductor and the equipment grounding conductor. B. They're often normal and typically intentional.C. They can't result from human error.D. They can happen if a conductive tool is dropped in an energized equipment's electrical enclosure.
Chapter 18 Solutions
EBK ELECTRICAL WIRING RESIDENTIAL
Ch. 18 - a. What circuit supplies the workshop lighting?...Ch. 18 - Prob. 2RCh. 18 - a. How is EMT fastened to masonry? _______________...Ch. 18 - What type of luminaires are installed on the...Ch. 18 - Prob. 5RCh. 18 - To what circuit are the smoke detectors connected?...Ch. 18 - Is it a Code requirement to connect smoke...Ch. 18 - Prob. 8RCh. 18 - Prob. 9RCh. 18 - Prob. 10R
Ch. 18 - Adjustment factors for conductor ampacities must...Ch. 18 - Prob. 12RCh. 18 - Prob. 13RCh. 18 - Calculate the total current draw of Circuit A17 if...Ch. 18 - Prob. 15RCh. 18 - A conduit body may contain splices if marked with...Ch. 18 - What size box would you use where Circuit A17...Ch. 18 - List the proper trade size of electrical metallic...Ch. 18 - According to the Code, what trade size EMT is...Ch. 18 - a. When more than three current-carrying...Ch. 18 - Prob. 21RCh. 18 - For laundry equipment in basements, what sort of...Ch. 18 - Prob. 23RCh. 18 - A Type NM cable carries a branch circuit to the...Ch. 18 - Prob. 25RCh. 18 - The following is a layout of the lighting circuits...Ch. 18 - Prob. 27RCh. 18 - Prob. 28R
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- 19. What size copper bonding jumper must be used in an AC electrical system that has 500 kcmil copper phase conductors? A. 4/0 B. 1/0 C. 2/0 D. 3/0 20. A neutral disconnect link is usually in the form of a _______ in larger service equipment. A. screwB. wireC. clamp D. busbararrow_forwardIf a grounding electrode conductor is connected at the first system disconnecting means or overcurrent device, the bonding jumper is sized the same as the ____. Select one: A. EQUIPMENT BONDING JUMPER B. POSITIVE CONDUCTOR C. SUPPLY-SIDE BONDING JUMPER D. NEUTRAL CONDUCTORarrow_forwardPlease answer in typing formatarrow_forward
- Service-lateral conductors are required to be insulated except for the grounded neutral conductor when it is___. A. Bare copper used in a raceway B. Bare copper & part of a cable assembly that is identified for ground use C. copper-clad Aluminum D. A or Barrow_forwardExpansion fittings and telescoping sections of metal raceways shall be made electrically continuous by _____ or other means. Select one: A. GROUNDING ELECTRODE B. GROUNDED CURRENT CARRYING CONDUCTOR C. EQUIPMENT BONDING JUMPERarrow_forwardhorizontal runs of IMC supported by openings through framing members at intervals not exceeding _____ ft and securely fastened within _____ ft of termination points shall be permitted. Select one: A. 1.5,4.5 B. 3,10 C. 2,5 D. 10,3arrow_forward
- equipment grounding 1. The only exception to the need for all information technology equipment to be satisfactorily grounded is where the equipment is A. DC powered.B. backup generator powered. C. double-insulated.D. isolated equipment. 2. Which section of the National Electrical Code lists sizing requirements for wire-type equipment grounding conductors? A. 250.66 B. 250.118 C. 250.4 D. 250.122arrow_forwardList the methods by which an equipment grounding conductor is connected to a device box.arrow_forwardA plug and connector used for cable termination is identified as 6P6C. The "6C" indicates that the connector has 6 contacts available. has 6 contacts installed. is the sixth connector. is for modems. Most of the loads supplied by an equipment branch are _______ V, three-phase. 480 120 360 240 A/An _______ is a type of hazardous location protective equipment that allows non-explosionproof motors to be used in Class I locations by supplying a continuous flow of clean air to remove flammable vapors. gas detection system explosionproof apparatus dust-ignition-proof apparatus purged and pressurized apparatus If you're installing a generator that's rated to provide 100 A of current, the conductors you use must have a minimum capacity of 142 A. 135 A. 115 A. 150 A.arrow_forward
- - Loads, Service, and Overcurrent Protection 6.a. The general lighting load is based on a _______ per square foot basis.A. kilowattB. number of circuitsC. volt-ampereD. general illumination6.b. What's the primary disadvantage of using copper conductors?A. AvailabilityB. WeightC. CostD. Durabilityarrow_forward1. What is the ideal line percent regulation rating? 2. Shunt voltage regulators require __________ samplingarrow_forward1. The only exception to the need for all information technology equipment to be satisfactorily grounded is where the equipment is A. DC powered.B. backup generator powered. C. double-insulated.D. isolated equipment. 2. Which section of the National Electrical Code lists sizing requirements for wire-type equipment grounding conductors? A. 250.66 B. 250.118 C. 250.4 D. 250.122 3. Which of the following statements about grounding electrical equipment is true?A. If no wire-type equipment grounding conductors are present with the branch circuits, the equipment grounding terminal bar isn't required.B. Grounding electrical equipment increases the possibility of metal parts remaining energized.C. The nonmetal parts of some electrical equipment are required to be connected to an equipment grounding conductor. D. Equipment grounding conductors can be spliced together outside of a grounded metal box. 4. Which of the following is a condition that must be met in order to qualify for the exemption…arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- EBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Types of Protective Relays and Design Requirements, Part 1a.; Author: GeneralPAC: Power System Tutorials;https://www.youtube.com/watch?v=JYil4T5VSDM;License: Standard Youtube License