Concept explainers
Saturated humid air at 70 psia and 200°F is cooled to 100°F as it flows through a 3-in-diameter pipe with a velocity of 50 ft/s and at constant pressure. Calculate the rate at which liquid water is formed inside this pipe and the rate at which the air is cooled.
The rate at which liquid water is formed inside this pipe and the rate at which the air is cooled.
Answer to Problem 86P
The rate at which liquid water is formed inside this pipe is
Explanation of Solution
The amount of moisture in the air remains constant as it flows through the heating section as process involves no dehumidification or humidification.
Here, specific humidity at state 1 and 2 is
Express initial partial pressure.
Here, relative humidity at state 1 is
Express initial humidity ratio.
Here, pressure at state 1 is
Express initial enthalpy.
Here, specific heat at constant pressure is
Express specific volume at state 1.
Here, gas constant of air is
Express final partial pressure.
Here, relative humidity at state 2 is
Express final humidity ratio.
Here, pressure at state 2 is
Express final enthalpy.
Here, final specific enthalpy saturated vapor at temperature of
Express volume flow rate of the dry air at inlet.
Here, velocity at state 1 is
Express mass flow rate of air.
As the process is a steady flow and thus the mass flow rate of dry air remains constant during the entire process.
Here, the mass flow rate of air at inlet is
Express the rate at which liquid water is formed inside this pipe by using an water mass balance.
Here, mass flow rate of water at inlet and exit is
Express the rate at which the air is cooled by using an energy balance.
Here, the rate of total energy entering the system is
Conclusion:
Refer Table A-2E, “ideal-gas specific heats of various common gases”, and write the properties of air.
Refer Table A-4E, “saturated water-temperature table”, and write the saturation pressure and initial specific enthalpy saturated vapor at temperature of
Substitute
Substitute
Substitute
Substitute
Refer Table A-4E, “saturated water-temperature table”, and write the saturation pressure and final specific enthalpy saturated vapor at temperature of
Substitute
Substitute
Substitute
Substitute
Substitute
Substitute
Hence, the rate at which liquid water is formed inside this pipe is
Refer Table A-4E, “saturated water-temperature table”, and write the enthalpy of saturation liquid at temperature of
Here, enthalpy of saturation liquid at temperature of
Substitute
Hence, the rate at which the air is cooled is
Want to see more full solutions like this?
Chapter 14 Solutions
CONNECT FOR THERMODYNAMICS: AN ENGINEERI
Additional Engineering Textbook Solutions
EBK FUNDAMENTALS OF THERMODYNAMICS, ENH
Automotive Technology: Principles, Diagnosis, And Service (6th Edition) (halderman Automotive Series)
Engineering Mechanics: Statics & Dynamics (14th Edition)
Fox and McDonald's Introduction to Fluid Mechanics
Fluid Mechanics Fundamentals And Applications
Vector Mechanics for Engineers: Dynamics
- Cold air enters the mixing chamber at 85°C and 105 kPa at a rate of 0.55 m /s, while warm air enters at 487°C and 105 kPa and the exit temperature of air leaving the chamber is 370.3 K. What is the ratio of the mass flow rates of the cold to hot air streams (m /m)arrow_forwardSaturated refrigerant-134a vapor at 34°C is to be condensed as it flows in a 1-cm-diameter tube at a rate of 0.1 kg/min. Determine the rate of heat transfer from the refrigerant. What would your answer be if the condensed refrigerant is cooled to 20°C?arrow_forwardA four-stage evaporator is used to evaporate sugar juice in the sugar manufacturing plant to produce syrup. Entering sugarcane juice is saturated liquid at 38.99kg/s with temperature of 104°C and leaves at 8.32kg/s. 10.22kg/s of juice is evaporated per stage. Steam entering the first stage has an enthalpy of 2489.40kJ/kg and has a mass flow rate of 40.32kg/s. The temperatures for the 4 stages are the following: 103.5°C, 94.5°C, 78.5°C, and 55°C. Determine the enthalpy of steam leaving the last stage. 2374.25kJ/kg 2563.24kJ/kg 2312.49kJ/kg 2687kJ/kgarrow_forward
- Air at a dry bulb temperature of 40℃ and a wet bulb temperature of 20℃ is first heated in a heater to a dry bulb temperature of 90℃. Then it is passed through a bed of apricot slices to dry them. The air exiting from the top of the apricot bed is at a dry bulb temperature of 60℃. Clearly show the various paths of the process on a psychrometric chart! Determine the amount of moisture removed, in grams of water/second from the apricot bed!arrow_forwardSteam at 40°C condenses on the outside of a 5-m-long, 3-cm-diameter thin horizontal copper tube by cooling water that enters the tube at 25°C at an average velocity of 2 m/s and leaves at 35°C. Determine the rate of condensation of steam.arrow_forwardSaturated water vapor at 40°C is to be condensed as it flows through a tube at a rate of 0.20 kg/s. The condensate leaves the tube as a saturated liquid at 40°C. The rate of heat transfer from the tube is (a) 34 kJ/s (b) 481 kJ/s (c) 2406 kJ/s (d) 514 kJ/s (e) 548 kJ/sarrow_forward
- Determine the enthalpy of steam at 127oC, at 75% quality, and flowing at the rate of 70 kg/h, if it is used to heat fluid soup. What is the volume in m3 of steam required per hour of operation?arrow_forward0.2kg of steam with an initial dryness of 0.7 is heated at constant pressure of 700kpa until volume is doubled determine the heat flow during the processarrow_forwardThe moist air with barometric pressure of 101.325 kPa enters a chamber at 2.5°C Wet bulb temperature and 5°C dry bulb temperature at the rate of 90 m3/min. While passing through the chamber, the air absorbs sensible heat at the rate of 42 kW and picks up 0.01 kg/sec of saturated steam at 105°C. Determine the dry bulb and wet bulb temperatures of the leaving air.arrow_forward
- Dry saturated steam at 8 bar expands in a convergent nozzle to a pressure of 0.5 bar and 0.8 dryness fraction. Determine the exit velocity of the steam if the initial velocity of the stream is 125m/sarrow_forwardA steam supply at 1.4MPA is formed from a mixture of steam at 1.4MPA and dryness fraction 0.9 and steam at 1.4MPA and temperature 250°C in the ratio 1:2 by mass. The mixture is then throttled down to a pressure of 0.28MPA. Determine a-the density of the mixture before throttling b-the temperature of steam after throttling. Take the specific heat of superheated steam as 2 kJ/kg K.arrow_forwardThe desired final conditions of the air in the room are 22 °C and 65% relative humidity. To achieve these conditions, outdoor air at 10 °C and 40% relative humidity is firstly heated to 18 °C and then humidified by steam injection. For an airflow rate of 50 m3/min, determine the rate of heat supplied and the mass flow rate of steam required for humidification. Make use of psychrometric charts.arrow_forward
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY