Thermodynamics: An Engineering Approach
8th Edition
ISBN: 9780073398174
Author: Yunus A. Cengel Dr., Michael A. Boles
Publisher: McGraw-Hill Education
expand_more
expand_more
format_list_bulleted
Question
Chapter 14.7, Problem 56P
To determine
The contribution of people to the total cooling load of the store.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Heat is produced by computers while they run. Do you have any questions concerning computer cooling systems?
The cooling load calculations on a theatre show that at design conditions the sensible heat load is 200 kw and the latent heat load is 70 kw. The indoor design conditions are 26°C dry bulb and50% relative humidity. Air is to be supplied to the theatre at 16°C while the outside airis at 30°C dry bulb and 60% relative humidity. Take ventilating air as 25% of the supply air. Calculate the tons of refrigeration required by the conditioner.
Are there any ways to overcome the limitations of natural ventilation such as unpredictable airflow and temperature differences? Is it more beneficial than not?
Chapter 14 Solutions
Thermodynamics: An Engineering Approach
Ch. 14.7 - What is the difference between dry air and...Ch. 14.7 - What is the difference between the specific...Ch. 14.7 - Can the water vapor in air be treated as an ideal...Ch. 14.7 - Is the relative humidity of saturated air...Ch. 14.7 - Is it possible to obtain saturated air from...Ch. 14.7 - Moist air is passed through a cooling section...Ch. 14.7 - How will (a) the specific humidity and (b) the...Ch. 14.7 - Prob. 8PCh. 14.7 - Consider a tank that contains moist air at 3 atm...Ch. 14.7 - Why are the chilled water lines always wrapped...
Ch. 14.7 - A tank contains 15 kg of dry air and 0.17 kg of...Ch. 14.7 - Prob. 12PCh. 14.7 - Prob. 13PCh. 14.7 - 14–13 A room contains air at 20°C and 98 kPa at a...Ch. 14.7 - A room contains air at 85F and 13.5 psia at a...Ch. 14.7 - An 8-m3 tank contains saturated air at 30C, 105...Ch. 14.7 - Prob. 17PCh. 14.7 - Prob. 18PCh. 14.7 - Prob. 19PCh. 14.7 - Andy and Wendy both wear glasses. On a cold winter...Ch. 14.7 - In summer, the outer surface of a glass filled...Ch. 14.7 - In some climates, cleaning the ice off the...Ch. 14.7 - Prob. 23PCh. 14.7 - Prob. 24PCh. 14.7 - Prob. 25PCh. 14.7 - Prob. 26PCh. 14.7 - A thirsty woman opens the refrigerator and picks...Ch. 14.7 - Prob. 28PCh. 14.7 - The air in a room has a dry-bulb temperature of...Ch. 14.7 - Prob. 31PCh. 14.7 - Prob. 32PCh. 14.7 - How do constant-enthalpy and...Ch. 14.7 - At what states on the psychrometric chart are the...Ch. 14.7 - How is the dew-point temperature at a specified...Ch. 14.7 - Can the enthalpy values determined from a...Ch. 14.7 - Prob. 37PCh. 14.7 - Prob. 39PCh. 14.7 - Prob. 41PCh. 14.7 - Prob. 42PCh. 14.7 - Prob. 43PCh. 14.7 - Prob. 44PCh. 14.7 - What does a modern air-conditioning system do...Ch. 14.7 - How does the human body respond to (a) hot...Ch. 14.7 - Prob. 47PCh. 14.7 - How does the air motion in the vicinity of the...Ch. 14.7 - Consider a tennis match in cold weather where both...Ch. 14.7 - Prob. 50PCh. 14.7 - Prob. 51PCh. 14.7 - Prob. 52PCh. 14.7 - What is metabolism? What is the range of metabolic...Ch. 14.7 - What is sensible heat? How is the sensible heat...Ch. 14.7 - Prob. 55PCh. 14.7 - Prob. 56PCh. 14.7 - Prob. 57PCh. 14.7 - Prob. 58PCh. 14.7 - Repeat Prob. 1459 for an infiltration rate of 1.8...Ch. 14.7 - An average person produces 0.25 kg of moisture...Ch. 14.7 - An average (1.82 kg or 4.0 lbm) chicken has a...Ch. 14.7 - How do relative and specific humidities change...Ch. 14.7 - Prob. 63PCh. 14.7 - Prob. 64PCh. 14.7 - Prob. 65PCh. 14.7 - Humid air at 40 psia, 50F, and 90 percent relative...Ch. 14.7 - Air enters a 30-cm-diameter cooling section at 1...Ch. 14.7 - Prob. 68PCh. 14.7 - Prob. 69PCh. 14.7 - Why is heated air sometimes humidified?Ch. 14.7 - Air at 1 atm, 15C, and 60 percent relative...Ch. 14.7 - Prob. 72PCh. 14.7 - An air-conditioning system operates at a total...Ch. 14.7 - Prob. 74PCh. 14.7 - Why is cooled air sometimes reheated in summer...Ch. 14.7 - Prob. 76PCh. 14.7 - Prob. 77PCh. 14.7 - Air enters a 40-cm-diameter cooling section at 1...Ch. 14.7 - Repeat Prob. 1479 for a total pressure of 88 kPa...Ch. 14.7 - Prob. 81PCh. 14.7 - Prob. 83PCh. 14.7 - Prob. 84PCh. 14.7 - Prob. 85PCh. 14.7 - Atmospheric air at 1 atm, 32C, and 95 percent...Ch. 14.7 - Prob. 88PCh. 14.7 - Prob. 89PCh. 14.7 - Does an evaporation process have to involve heat...Ch. 14.7 - Prob. 93PCh. 14.7 - Prob. 94PCh. 14.7 - Air at 1 atm, 20C, and 70 percent relative...Ch. 14.7 - Two unsaturated airstreams are mixed...Ch. 14.7 - Consider the adiabatic mixing of two airstreams....Ch. 14.7 - Prob. 98PCh. 14.7 - Two airstreams are mixed steadily and...Ch. 14.7 - A stream of warm air with a dry-bulb temperature...Ch. 14.7 - Prob. 104PCh. 14.7 - How does a natural-draft wet cooling tower work?Ch. 14.7 - What is a spray pond? How does its performance...Ch. 14.7 - The cooling water from the condenser of a power...Ch. 14.7 - Prob. 108PCh. 14.7 - A wet cooling tower is to cool 60 kg/s of water...Ch. 14.7 - Prob. 110PCh. 14.7 - Prob. 111PCh. 14.7 - Prob. 112PCh. 14.7 - Prob. 113RPCh. 14.7 - Prob. 114RPCh. 14.7 - Prob. 115RPCh. 14.7 - Prob. 116RPCh. 14.7 - Prob. 117RPCh. 14.7 - Prob. 118RPCh. 14.7 - Prob. 119RPCh. 14.7 - Prob. 120RPCh. 14.7 - 14–121 The relative humidity inside dacha of Prob....Ch. 14.7 - Prob. 122RPCh. 14.7 - Prob. 124RPCh. 14.7 - 14–126E Air at 15 psia, 60°F, and 70 percent...Ch. 14.7 - Prob. 127RPCh. 14.7 - Air enters a cooling section at 97 kPa, 35C, and...Ch. 14.7 - Prob. 129RPCh. 14.7 - Humid air at 101.3 kPa, 36C dry bulb and 65...Ch. 14.7 - 14–131 Air enters an air-conditioning system that...Ch. 14.7 - Prob. 132RPCh. 14.7 - Prob. 133RPCh. 14.7 - Conditioned air at 13C and 90 percent relative...Ch. 14.7 - Prob. 138RPCh. 14.7 - A room is filled with saturated moist air at 25C...Ch. 14.7 - Prob. 141FEPCh. 14.7 - A 40-m3 room contains air at 30C and a total...Ch. 14.7 - Prob. 143FEPCh. 14.7 - The air in a house is at 25C and 65 percent...Ch. 14.7 - On the psychrometric chart, a cooling and...Ch. 14.7 - On the psychrometric chart, a heating and...Ch. 14.7 - An airstream at a specified temperature and...Ch. 14.7 - Prob. 148FEPCh. 14.7 - Air at a total pressure of 90 kPa, 15C, and 75...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Which of the three air-conditioning possible systems listed below should be used to maintain the indoor temperature of a house at 20°C while resulting in a daily lower operating cost when the outdoor temperature is -2°C. Based on the construction of the house you estimate that under the given indoor and outdoor temperatures the rate of heat loss to the surroundings is 17 kJ/s. Which system would you recommend as a feasible alternative? Support your answer for each one of the cases below with convincing computations that show which one of the systems is requires the minimum electrical power while being in compliance with the first and second law of thermodynamics. a. Electrical heating b. A heat pump with COPHP = 3.0 c. A heat pump with COP = 14.0arrow_forwardDifferentiate boiler feed water and engine cooling water in terms of its characteristics including phase, properties, and usage.arrow_forwardDiscussion: 1. Explain the benefits of psychometric chart in solving air conditioning problems. 2. Define dry bulb and wet bulb temperatures and explain at which state they would be equal. 3. Why dry air and water vapor during calculating the properties of moist air are treated separately, explain. 4. Discuss the air conditioning processes that are obtained in the experiment and calculated results. 5. What factors are considered in measuring the wet bulb temperature and what is the recommended air speed over the wet bulb in a Sling Psychomotor?arrow_forward
- How to solve theoretical efficiency of the cooling tower regarding air and water entering the system? Please provide examples. Subject : Heat transferarrow_forwardThe sensible effectiveness of a heat recovery ventilator is 53.6%. The inlet temperature of fresh air is 35°C and relative humidity is 50%. The inlet temperature of exhaust air is 24°C and relative humidity is 60%. The mass flow rates of fresh air and exhaust air are 1.3 kg/s and 1.5 kg/s, respectively. Calculate the outlet fresh air temperature and estimate the energy saving ratio of adopting heat recovery ventilator.arrow_forwardA storeroom of dimensions 10 x 8 x 3 m is maintained at 21oC and 50% RH and has a total heating load of 10 kW. The room is provided with 8 air changes per hour when ambient conditions are 30oC and 60% RH. Determine: a. the total cooling rate b. moisture removed per hour c. the minimum diameter of the fresh air duct so that the velocity in the duct does not exceed 3 m/sarrow_forward
- Explain why a heat pump system is more cost-effective in winter season in Alaska but not in houses in Cameron Highlands.arrow_forwardA space to be conditioned has a sensible heat load of 80 kw and a latent heat load of 20 kw and is to be maintained at 20°C and 50% relative humidity. Outside air is at 35°C and 60% RH. The conditioned air will enter the space at 15°C. If 40% of the supply air is fresh and the rest is recirculated, the refrigeration capacity of the system is nearest to what value? 430 kw 455 kw 428 kw Ⓒ333 kwarrow_forwardA heating system that uses hot air has a total heating load of 509 thousand btuh. How much hot air flow in CFM is required to satisfy the total load if the temperature difference is 23?arrow_forward
- Explain why the HVAC systems, new roof, interior renovation costs, additional plumbing, and restroom partitions have the same recovery life as the buildings.arrow_forward9. A large warehouse located at an altitude of 1500 m has to be maintained at a DBT of 270C and a relative humidity of 50% using a direct evaporative cooling system. The outdoor conditions are 330C (DBT) and 150C (WBT). The cooling load on the warehouse is 352 kW. A supply fan located in the downstream of the evaporative cooler adds 15 kW of heat. Find the required mass flow rate of air. Assume the process in evaporative cooler to follow a constant WBT. 10. A winter air conditioning system maintains a building at 210C and 40% RH. The outdoor conditions are OoC (DBT) and 100% RH. The sensible load load on the building is 100 kW, while the latent heating load is 25 kW. In the air conditioning system, 50% of the outdoor air (by mass) is mixed with 50% of the room air. The mixed air is heated in a pre-heater to 250C and then required amount of dry saturated steam at 1 atm. pressure is added to the pre-heated air in a humidifier. The humidified air is then heated to supply temperature of…arrow_forwardCalculate the EER rating of a 20 ton (240000 Btu) air conditioning unit with an average electrical load of 30 kW. An air conditioning plant supplies air to a room at a rate of 2.5 kg/s, the supply air being made up of equal parts by weight of outdoor and recirculated air. The mixed air passes through a cooler coil fitted with a by-pass duct, face and by pass dampers being used for humidity control. The air then passes through an after heater and supply fan. In a test on the plant, the following conditions (Table Qu 4) were recorded; 3 Table Qu. 4: Parameters recorded Relative humidity Dry bulb temperature °C Wet bulb temperature °C % Outdoor air 270 20.5 Room air 210 50 Supply air Air leaving cooler 160 11.8 80 90 coil Make neat sketches showing the plant arrangement and the psychrometric cycle and identify the corresponding points on both diagrams. Calculate the following; mass of air through the cooler coil load on cooler coil load on heaterarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Refrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning
Refrigeration and Air Conditioning Technology (Mi...
Mechanical Engineering
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:Cengage Learning
The Refrigeration Cycle Explained - The Four Major Components; Author: HVAC Know It All;https://www.youtube.com/watch?v=zfciSvOZDUY;License: Standard YouTube License, CC-BY