A steam power plant operates on an ideal reheat-regenerative Rankine cycle and has a net power output of 80 MW. Steam enters the high-pressure turbine at 10 MPa and 550°C and leaves at 0.8 MPa. Some steam is extracted at this pressure to heat the feedwater in an open feedwater heater. The rest of the steam is reheated to 500°C and is expanded in the low-pressure turbine to the condenser pressure of 10 kPa. Show the cycle on a T-s diagram with respect to saturation lines, and determine (a) the mass flow rate of steam through the boiler and (b) the thermal efficiency of the cycle.
Want to see the full answer?
Check out a sample textbook solutionChapter 10 Solutions
THERMODYNAMICS LLF W/ CONNECT ACCESS
Additional Engineering Textbook Solutions
Vector Mechanics for Engineers: Statics
Fundamentals Of Thermodynamics
Vector Mechanics For Engineers
Fluid Mechanics: Fundamentals and Applications
Heat and Mass Transfer: Fundamentals and Applications
Foundations of Materials Science and Engineering
- Consider a 150-MW steam power plant that operates on a simple Rankine cycle. Steam enters the turbine at 7 MPa and 500°C and is cooled in the condenser at 10 kPa. Calculate the volume flow rate of sea water (S.G. = 1.05) used in the condenser, if the allowable temperature rise is 5°C. Assume an isentropic efficiency of 87% for both the turbine and the pump.arrow_forwardA simple ideal Rankine cycle which uses water as the working fluid operates its condenser at 40C and its boiler at 300C. Calculate the work produced by the turbine, the heat supplied in the boiler, and the thermal efficiency of this cycle when the steam enters the turbine without any superheating.arrow_forwardAn ideal reheat Rankine cycle with water as the working fluid operates the inlet of the high-pressure turbine at 7000 kPa and 450°C, the inlet of the low-pressure turbine at 500 kPa and 500°C, and the condenser at 10 kPa. Determine the mass flow rate through the boiler needed for this system to produce a net 5000 kW of power and the thermal efficiency of the cycle. Use steam tables. kg/s. The mass flow rate through the boiler needed for this system to produce a net 5000 kW of power is The thermal efficiency is %.arrow_forward
- In a Rankine cycle with reheating, the steam leaves the boiler at 2.5 MPa and 600 ºC and enters the high-pressure turbine where it expands to a pressure of 1 MPa to be then subjected to a reheating process from where it leaves at 1 MPa and 600 ° C. The steam at these conditions enters the low-pressure turbine and expands up to the condenser pressure of 50 kPa. The heat that is extracted in the condenser is 1500 kJ / s. If the adiabatic efficiency of the turbines and the pump is 95%, determine the total heat flow in kJ / s delivered to the boiler.arrow_forwardIn a Rankine cycle with reheating, the steam leaves the boiler at 2.5 MPa and 600 ºC and enters the high pressure turbine where it expands to a pressure of 1 MPa to be then subjected to a reheating process from where it leaves at 1 MPa and 600 ° C. The steam at these conditions enters the low pressure turbine and expands up to the condenser pressure of 50 kPa. The heat that is extracted in the condenser is 1500 kJ / s. If the adiabatic efficiency of the turbines and the pump is 95%, determine the total heat flow in kJ / s delivered to the boiler.arrow_forwardIn an ideal reheat-regenerative cycle, steam enters the turbine at 6 MPaa and 400°C. After expansion to 1.4 MPaa steam is withdrawn and reheated to 300°C. Extractions for regenerative heating occur at 0.15 MPaa and 1.4 MPaa and the condenser pressure is 0.01MPaa. Use mass flowrate of 1 kg/s.arrow_forward
- Refrigerant-134a is used as the working fluid in a simple ideal Rankine cycle which operates the boiler at 2000 kPa and the condenser at 24C. The mixture at the exit of the turbine has a quality of 93 percent. Determine the turbine inlet temperature, the cycle thermal efficiency, and the back-work ratio of this cycle.arrow_forwardAn ideal reheat 210 MW Rankine cycle with water as the working fluid operates the boiler at 15 MPa, the reheater at 2 MPa, and the condenser at 10 kPa. The temperature is 500 0C at the entrance of the high-pressure and low-pressure turbines. Determine (a) the quality of the steam at the low-pressure turbine exit, (b) the thermal efficiency of this system, and (c) the rate of heat transfer in the reheater.arrow_forwardConsider an ideal steam regenerative Rankine cycle with two feedwater heaters, one closed and one open. Steam enters the turbine at 10 MPa and 500 C and exhausts to the condenser at 10 kPa. Steam is extracted from the turbine at 0.7 MPa for the closed feedwater heater and 0.3 MPa for the open one. The extracted steam leaves the closed feedwater heater and is subsequently throttled to the open feedwater heater. Show the cycle on a T-s diagram with respect to saturation lines, and using only the data presented in the data tables given below determine a) the fraction for steam leaving the boiler that is extracted at 0.3 MPa z=0.1425 b) the fraction of steam leaving the boiler that is extracted at 0.7 MPa y=0.06213 c) the heat transfer from the condenser per unit mass leaving the boiler q_out=1509 kJ/kg d) the heat transfer to the boiler per unit mass leaving the boiler qin=2677 kJ/kg e) the mass flow rate of steam through the boiler for a net power output of 250 MW m'=214.1 kg/s f) the…arrow_forward
- Required information NOTE: This is a multi-part question. Once an answer is submitted, you will be unable to return to this part. Consider a steam power plant that operates on a reheat Rankine cycle and has a net power output of 80 MW. Steam enters the high-pressure turbine at 10 MPa and 500°C and the low-pressure turbine at 1 MPa and 500°C. Steam leaves the condenser as a saturated liquid at a pressure of 10 kPa. The isentropic efficiency of the turbine is 72 percent and that of the pump is 95 percent. Determine the quality (or temperature, if superheated) of the steam at the turbine exit. Use steam tables. (You must provide an answer before moving on to the next part.) The temperature of the steam at the turbine exit is °C.arrow_forwardA simple ideal Rankine cycle which uses water as the working fluid operates its condenser at 40C and its boiler at 300C. The steam enters the turbine without any superheating. Determine the thermal efficiencyarrow_forward3.) A steam power plant uses the ideal Reheat-Regenerative Rankine cycle where the steam enters the high-pressure turbine at 4 MPa and 300C. It partially expands to 600 kPa where some steam is extracted for feedwater heating while the rest is reheated to the same temperature. After expanding again, it enters the condenser at 10 kPa. Sketch the schematic diagram and the TS diagram with labeled points, and solve for mass taken for feedwater heating, Qa, Qr, Wt, Wp, Wnet, thermal efficiency, and Steam rate. Neglect the condensate pump work. kJ kj kJ kJ kJ kg 1715.88- 20.01%, 2667.84- 955.97 3.74 951.96 35.68%, 3.78. " J kg kg kg kg kWh kg "arrow_forward
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY