Delmar's Standard Textbook Of Electricity
7th Edition
ISBN: 9781337900348
Author: Stephen L. Herman
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Textbook Question
Chapter 10, Problem 12RQ
It is decided to use parallel 0000 conductors to supply the load in Question 11. How many 0000 conductors will be needed?
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
No plagarism please!
Correct and detailed answer will be Upvoted else downvoted. Thank you!
Discuss the arcing phenomenon in a circuit breaker.
Please write more answer
Q2. The single-line diagram of a simple three-bus power system
is shown in Figure-2. Each generator is represented by an emf
behind the sub-transient reactance. All impedances are
expressed in per unit on a common MVA base. All resistances
and shunt capacitances are neglected. The generators are
operating on no load at their rated voltage with their emfs in
phase. A three-phase fault occurs at bus 3 through a fault
impedance of Zf = j0.19 per unit.
(i) Using Th'evenin's theorem, obtain the impedance to the
point of fault and the fault current in
(ii) Determine the bus voltages
per
unit.
) j0.05
j0.075
j0.75
2
j0.30
j0.45
Figure-2: Single line diagram of the
power system network for Q2
3
Chapter 10 Solutions
Delmar's Standard Textbook Of Electricity
Ch. 10 - What is the maximum temperature rating of Type...Ch. 10 - 2. Name two types of conductor insulation designed...Ch. 10 - A 10 AWG copper conductor with Type THW insulation...Ch. 10 - 4. Six 1/0 aluminum conductors are to be run in a...Ch. 10 - Name five conditions that must be met for running...Ch. 10 - What is the largest solid (nonstranded) conductor...Ch. 10 - Can Type TW cable be used in an area that has an...Ch. 10 - How is the grounded conductor in a flat...Ch. 10 - What three colors are ungrounded conductors not...Ch. 10 - Twenty-five 12 AWG copper conductors are run in...
Ch. 10 - A single-hase load is located 2800 ft from its...Ch. 10 - It is decided to use parallel 0000 conductors to...Ch. 10 - A three-phase motor operates on 480 V and is...Ch. 10 - You have been hired by a company to connect an...Ch. 10 - 2. You are a journeyman electrician in an...Ch. 10 - You are an electrician working in an industrial...Ch. 10 - Using the above example, determine the wire size...Ch. 10 - 1. A 2 AWG copper conductor is 450 ft long. What...Ch. 10 - 2. An 8 AWG conductor is 500 ft long and has a...Ch. 10 - 3. Three 500-kcmil copper conductors with Type RHH...Ch. 10 - 4. Eight 10 AWG aluminum conductors with Type THWN...Ch. 10 - 5. A three-phase motor is connected to 480 V and...Ch. 10 - 6. A 50-hp DC motor is connected to 250 volts. The...Ch. 10 - 7. A bank of electric heaters has a power rating...Ch. 10 - A 15-hp squirrel-cage induction motor is connected...Ch. 10 - Determine the resistance of a 16 AWG copper...Ch. 10 - Determine the ohms-per-mil-foot of an aluminum...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- pure dc will have ____ ripplearrow_forwardThe symmetrical short circuit current is ______________________ quantity in nature. a-Exponential b-Ramp c-Alternating d-Directarrow_forwardTransmission and distribution lines are important components of any power system study. Aluminium cable steel reinforced (ACSR) (with steel in the centre – as shown in Figure Q1 is normally chosen instead of copper for transmission Explain: (a)The choice of aluminium instead of copper (b)The need to use and place steel at the corearrow_forward
- 12 - Due to the effect of the resistance of the cable connected to RTD, two-wire cables up to ……. meters and three-wire cables up to ……... meters are used in standard designs. A) 10-150B) 40-500C) 50-195D) 30-230E) 200-1000arrow_forwardAn ac resistance is higher than a dc resistance. True Falsearrow_forwardSome electricians do not bother to calculate the minimum size of neutral service conductor. They size the minimum ungrounded conductor size and then use this information to determine the minimum neutral conductor size. Explain how they determine the minimum neutral size using the minimum ungrounded conductor sizarrow_forward
- 5arrow_forwardThe principle operation of LVDT is based on the variation of Select one a. Self inductance b. Reluctance c. Mutual inductance d. Permanencearrow_forwardFor same power transfer, same material and same length and same power loss. If the voltage is increased by 4 times. What will happen to the area of cross section of conductor?arrow_forward
- h.1. In an alternating-current system, the maximum size for a copper grounding electrode conductor isA. 250 kcmil.B. 3/0.C. 500 kcmil.D. 4/0. h.2. The figure shows a fault condition in an ungrounded electrical system. Which of the following will occurbecause of the fault in this system?A. Only the overcurrent protector at Point A will trip open.B. The ground fault will heavily damage the service.C. Nothing will happen until a second ground fault occurs.D. The overcurrent protection will trip, shutting off all the line side power.arrow_forwardPower systemarrow_forwardThe value of symmetrical short circuit current is ___________________ at time t=0. Zero Minimum Unity Maximumarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Delmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningPower System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage LearningEBK ELECTRICAL WIRING RESIDENTIALElectrical EngineeringISBN:9781337516549Author:SimmonsPublisher:CENGAGE LEARNING - CONSIGNMENT
- Electricity for Refrigeration, Heating, and Air C...Mechanical EngineeringISBN:9781337399128Author:Russell E. SmithPublisher:Cengage Learning
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
EBK ELECTRICAL WIRING RESIDENTIAL
Electrical Engineering
ISBN:9781337516549
Author:Simmons
Publisher:CENGAGE LEARNING - CONSIGNMENT
Electricity for Refrigeration, Heating, and Air C...
Mechanical Engineering
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Cengage Learning
Why HIGH VOLTAGE DC power Transmission; Author: ElectroBOOM;https://www.youtube.com/watch?v=DFQG9kuXSxg;License: Standard Youtube License